Date Text
2020-10-05 12:20:35THE FOLLOWING COMENTS FROM THE STORMWATER STOP#5 WERE
 ADDRESSED THROUGH EMAILS. COMMENT #3 WILL BECOME A
 CONDITION OF SITE PLAN APPROVAL.
  
 1. WHERE DOES STORMWATER RUNOFF FROM TANDEM PARKING
 SPACES DRAIN TO? THE EOR SUBMITTED A ROUGH SKETCH
 SKETCH SHOWING HOW THE MEP MAY DESIGN A STORMWAER
 COLLECTION SYSTEM TO ROUTE THE STORMWATER RUNOFF TO THE
 STORMCEPTER STRUCTURE. THE ACTUAL DESIGN WILL NEED TO
 BE SUBMITTED WITH THE ENGINEERING PERMIT SUBMITTAL.
  
  
 3.THE BACK OF SIDEWALK FOR THE DRIVEWWAYS TO BARCELONA
 ROAD AND TO CORDOVA ROAD SHALL BE THE HIGH POINT AND
 THE PAVEMENT BEHIND THE SIDEWALK SLOPED TO DRAIN TO THE
 INTERIOR OF THE SITE. NOT ENOUGH INFORMATION HAS BEEN
 PROVIDED TO ADDRESS THIS COMMENT. THE PARKING GARAGE
 PLANS APPEAR TO TAKE INTO CONSIDERATION AREAS FOR
 STORMWATER MANAGEMENT BUT THESE AREAS MAY NEED BE BE
 ENLARGED TOWARD THE SOUTH IF THE CURRENT FOOTPRINT
 CANNOT ACCOMMODATE THE PLACEMENT OF THE DRAINAGE SYSTEM
 TO BE LOWER THAN THE BACK OIF SIDEWALK. A CONDITION OF
 THE SITE PLAN APPROVAL SHALL BE THE BACK OF SIDEWALK BE
 AT LEAST 0.1 FEET HIGHER THAN THE INTERIIOR DRIVEWAY
 GRADES.
  
 4. WHERE DOES AREA EAST OF THE SOUTH BUILDING DRAIN TO?
 THE EOR SUBMITTED A ROUGH SKETCH SKETCH SHOWING HOW THE
 MEP MAY DESIGN A STORMWAER COLLECTION SYSTEM TO ROUTE
 THE STORMWATER RUNOFF TO THE STORMCEPTER STRUCTURE. THE
 ACTUAL DESIGN WILL NEED TO BE SUBMITTED WITH THE
 ENGINEERING PERMIT SUBMITTAL.
  
  
 TRACY WARD, PE
 SENIOR STORMWATER ENGINEER
 ENGINEERING SERVICES DEPARTMENT