Plan Review Notes
Plan Review Notes For Project Z19050024
Project Number Z19050024
Review Stop STORM
Sequence Number 5
Notes
Date Text
2020-09-25 16:50:09THE FOLLOWING COMMENTS ARE FROM THE REVIEW OF THE
 9/11/2020 SUBMITTAL SET OF PLANS.
  
 1. WHERE DOES STORMWATER RUNOFF FROM TANDEM PARKING
 SPACES DRAIN TO? [NOT SATISFIED] THE RESPONSE TO THIS
 COMMENT DISCUSSED THE ONSTREET PARALLEL PARKING SPACES.
 THIS COMMENT IS REFERRING TO THE EAST SIDE OF THE
 PROPOSED BUIDLING BETWEEN FLAMINGO DRIVE AND BARCELONA
 ROAD, WHERE THERE ARE TRAVEL LANES IN BOTH DIRECTIONS
 SEPARATED BY A BI-DIRECTIONAL TRAVEL LANE. IF DRAINAGE
 SYSTEM WILL BE ON THE MEP PLANS, THEN FOR THE
 CONCEPTUAL ENGINEERING PLAN, SHOW INLET AND PIPING WITH
 A NOTEE THAT FINAL DESIGN WILL BE ON THE MEP PLANS.
  
 2. THE BACK OF WALK FOR THE EAST DRIVEWAY TO FLAMINGO
 DRIVE SHALL BE THE HIGH POINT FOR THE DRIVEWAY SOUTH OF
 THE SIDEWALK.[SATISFIED]
  
 3.THE BACK OF SIDEWALK FOR THE DRIVEWWAYS TO BARCELONA
 ROAD AND TO CORDOVA ROAD SHALL BE THE HIGH POINT AND
 THE PAVEMENT BEHIND THE SIDEWALK SLOPED TO DRAIN TO THE
 INTERIOR OF THE SITE.[PARTIALLY SATISFIED] THE LOADING
 AREA SOUTH OF BARCELONA ROAD SHALL HAVE A LOW SPOT
 SOUTH OF THE SIDEWALK. MOVE CASCADE SEPARATOR SOUTH AND
 SHOW FLOW ARROW.
  
 4. WHERE DOES AREA EAST OF THE SOUTH BUILDING DRAIN TO?
 [REPEAT COMMENT] RESPONSE STATED DESIGN WILL BE SHOWN
 ON MEP PLANS. SHOW FLOW ARROW FOR RAMP. SINCE THIS IS
 CONCEPTUAL ENGINEERING PLAN, SHOW GRATE AND POSSIBLE
 PIPING TO THE CASCADE SEPARATOR. IF MEP WILL BE
 PROVIDING THE FINAL DESIGN, THEN A NOTE CAN BE ADDED TO
 THE PLAN INDICATING THIS.
  
 5. CURB RAMPS ON THE NE CORNER OF FLAMINGO ROAD/S.
 DIXIE HWY AND THE SE CORNER OF CORDOVA ROAD/S. DIXIE
 HWY TO BE RECONSTRUCTED TO MEET CURRENT ADA
 CRITERIA.[SATISFIED]
  
 6. CONFIRM WITH FDOT THE MILL AND OVERLAY LIMITS ON S.
 DIXIE HWY.[SATISFIED]
  
 7. SHOW DRIVEWAY FOR 327 CORDOVA DRIVE AND THE STREET
 LIGHT TO THE WEST OF THE DRIVEWAY. [SATISFIED]
  
 8. SHOW LOCATION OF EXISTING LIGHTPOLES ON FLAMINGO
 DRIVE. [SATISFIED]
  
 9. STORMWATER DESIGN FOR FLAMINGO DRIVE AND BARCELONA
 ROAD TO INCLUDE TOPOGRAPHIC SURVEY OF RIGHT OF WAY
 BATWEEN S. DIXIE HWY AND S. OLIVE AVE., SHOW ALL
 EXISTING UTILITIES IN THE RIGHT OF WAY AND
 HORIZONTAL/VERTICAL SEPARATION BETWEEN STORM PIPE AND
 EXISTING UTILITIES. THIS CAN BE PROVIDED WITH
 ENGINEERING PERMIT SUBMITTAL.[SATISFIED] RESPONSE AND
 COMMENT INDICATED THIS COMMENT CAN BE ADDRESSED DURING
 ENGINEERING PERMIT SUBMITTAL.
  
 TRACY WARD, PE
 SENIOR STORMWATER ENGINEER
 ENGINEERING SERVICES DEPARTMENT
 561-494-1120 (O)
 561-351-0510 (M)
 [email protected]
  
  