2019-10-30 16:35:30FROM: RAY CARANCI, LANDSCAPE PLANNER 561-822-1462
 PROJECT: 2000 S DIXIE CAREFREE Z19050024
 OCTOBER 30, 2019
 I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND
 PROVIDE THE FOLLOWING COMMENTS:
  
  
 1. PARTIALLY SATISFIED. PROVIDE A TREE DISPOSITION PLAN
 FOR THE SITE AND SHOW TREE CANOPY MITIGATION REQUIRED
 AND PROVIDED WITH THIS PETITION.
 ADDRESS THE FOLLOWING:
 ? IDENTIFY TREE #5
 ? REMOVE ERM REFERENCES FORM MULTIPLE LOCATIONS ON
 SHEET TD-1 AND REMOVE UNNECESSARY COLUMNS.
 ? PROVIDE THE FOLLOWING COLUMNS ON THE DISPOSITION
 CHART: CANOPY DIAMETER, TREE CATEGORY, TREE CONDITION,
 AND SQUARE FOOTAGE MITIGATION DUE, AND PROVIDE THE
 INFORMATION FOR EACH TREE IN EACH COLUMN.
 ? PROVIDE THE MITIGATION DUE TOTAL AT THE BOTTOM OF THE
 CHART.
 ? ADJUST JAPANESE BLUEBERRY CANOPY CREDIT TO 150 SQ FT
 FOR CATEGORY 2.
  
 2. PARTIALLY SATISFIED. SUBMIT A LANDSCAPE PERMIT PLAN
 FOR 309 BARCELONA MEETING THE MINIMUM CODE REQUIREMENTS
 FOR RESIDENTIAL LANDSCAPING AND MITIGATING FOR TREES
 REMOVED.
 A TREE ALTERATION PERMIT APPLICATION WAS SUBMITTED FOR
 THE ADDITIONAL TREES REMOVED, AND THE PERMIT WAS ISSUED
 WITH CONDITIONS. MITIGATION IS DUE FOR ALL THE TREES
 REMOVED AND MUST BE ADDRESSED WITH REPLACEMENT OF TREES
 ON SITE OR PAYMENT IN LIEU. THE MINIMUM LANDSCAPE
 REQUIREMENTS MUST BE MET ON SITE WITH A LANDSCAPE
 PERMIT PLAN TO BE SUBMITTED. NO MITIGATION HAS BEEN
 PROVIDED TO DATE FOR ANY TREES REMOVED FROM THE SITE.
  
 3. NOT SATISFIED. PROVIDE A LANDSCAPE PLAN FOR THE
 AMENITY DECKS IF INTENDED AS JUSTIFICATION FOR THE
 WAIVER REQUESTS.
  
 4. SATISFIED. PROVIDE AN OPEN SPACE DIAGRAM TO
 DEMONSTRATE THE AREAS PROVIDED AS OPEN SPACE AND
 LANDSCAPE AREAS ON SITE WITHIN THE PROPERTY LINES TO
 PROVIDE REFERENCE FOR THE WAIVER REQUESTS.
  
 5. NOT SATISFIED. WAIVER REQUESTS #7 AND 8 NEED TO BE
 REVISED TO SHOW THAT 15% LANDSCAPE AREA IS REQUIRED PER
 THE CURRENT CODE.
 THERE IS AN ERROR ON THE CODE CHART THAT WILL BE
 CORRECTED. MAXIMUM IMPERVIOUS AREA IS 85%, THEREFORE
 MINIMUM LANDSCAPE AREA IS 15%.
  
 6. SATISFIED. WAIVER REQUEST #9 NEEDS TO REFERENCE
 SECTION 94-443(A) BUFFERING OF NON-RESIDENTIAL USES
 ADJACENT TO RESIDENTIAL PROPERTY FOR THE EAST BUFFERS
 AND 94-443(D) ADDITIONAL LANDSCAPING REQUIREMENTS FOR
 MULTIFAMILY RESIDENTIAL USES FOR THE BUFFERS ADJACENT
 TO PUBLIC THOROUGHFARES THAT ARE REQUIRED TO BE 10 FEET
 IN WIDTH.
  
 7. PARTIALLY SATISFIED. PROVIDE MEASUREMENTS AND
 CALCULATIONS FOR THE BUFFER TREES REQUIRED FOR ALL
 BUFFER LENGTHS PER SECTION 94-443 B. AND INDICATE HOW
 THIS WILL BE AFFECTED THROUGH THE WAIVER REQUESTS.
 INDICATE THE WIDTH OF ALL LANDSCAPE BUFFERS PROVIDED ON
 THE LANDSCAPE PLAN. THE STREET TREES THAT ARE NOT
 AFFECTED BY OVERHEAD UTILITIES NEED TO BE UPGRADED TO
 CATEGORY 1 SHADE TREES IF USED AS A JUSTIFICATION FOR
 WAIVERS.
  
 WAIVER IS FOR WIDTH OF BUFFER PROVIDED, PROVIDE A
 REFERENCE OF THE NUMBER OF TREES THAT WOULD BE REQUIRED
 ALONG EACH BUFFER SEGMENT AND COMPARE TO THE NUMBER
 PROVIDED WITHIN EACH BUFFER AND ADJACENT RIGHT OF WAY.
 OAKS CANNOT BE USED ON DIXIE, AS THERE ARE OVERHEAD
 ELECTRIC LINES.
  
  
 8. NOT SATISFIED. PROVIDE LOCATIONS OF LIGHTING ON THE
 LANDSCAPE PLAN TO AVOID CONFLICTS WITH LANDSCAPING.
  
 9. NOT SATISFIED. SHOW LOCATIONS OF ROOT BARRIERS TO
 PROTECT INFRASTRUCTURE AND TREES FROM CONFLICTS. THIS
 INCLUDES WATER, SEWER, DRAINAGE, SIDEWALKS AND CURBS,
 AND ANY FIELD STRUCTURES THAT COULD BE IMPACTED BY TREE
 ROOTS.
  
 10. NOT SATISFIED. SHOW LOCATIONS OF ALL GROUND MOUNTED
 EQUIPMENT INCLUDING FPL TRANSFORMERS, A/C UNITS, ETC.,
 AND PROVIDE SCREENING FOR ALL GROUND MOUNTED EQUIPMENT
 AND UTILITIES.
  
 ADDITIONAL COMMENTS 10/30/19:
 11. SECTION 94-448 (D)(3) REQUIRES NATIVE TREES IN GOOD
 CONDITION TO BE PRESERVED ON SITE OR RELOCATED. ONCE
 TREE#5 IS CORRECTLY IDENTIFIED, AND THE CONDITION OF
 EACH TREE AND PALM ADDED, THE NUMBER OF TREES AND PALMS
 REQUIRED TO BE RELOCATED CAN BE DETERMINED.
  
 12. PROVIDE JUSTIFICATION FOR ALL LANDSCAPE WAIVERS.
  
  
  
 CONDITIONS OF APPROVAL
 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON
 THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE
 SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT
 SERVICES DEPARTMENT, PLANNING DIVISION.
 2. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE
 RESPONSIBLE FOR THE PERMITTING AND INSTALLATION OF THE
 STREET TREES AND RIGHT OF WAY LANDSCAPING AND
 IRRIGATION APPROVED WITH THIS PETITION.
 3. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE
 RESPONSIBLE FOR THE MAINTENANCE OF THE ROAD RIGHT OF
 WAY LANDSCAPING AND IRRIGATION. THIS WILL BE THROUGH A
 SEPARATE MAINTENANCE AGREEMENT WITH THE CITY.
  