| Date |
Text |
| 2019-12-06 15:10:13 | THE SUBMITTED COMMENT RESPONSE LETTER SIMPLY STATES |
| | "ACKNOWLEDGED" FOR ALL COMMENTS EXCEPT COMMENT 7 FOR |
| | WHICH THE RESPONSE IS "THIS WILL BE ADDRESSED AT FINAL |
| | DESIGN IN BUILDING PERMIT REVIEW". SO THERE IS NO |
| | NARRATIVE TO STATE HOW THE COMMENTS ARE BEING |
| | ADDRESSED. IF THE PLANNER IS OK WITH DEFERRING |
| | RESPONSES ALL COMMENTS CAN BE ADDRESSED WITH THE |
| | BUILDING PERMIT APPLICATION, HOWEVER RESPONSE TO |
| | COMMENTS 2, 3 AND 5, ARE MOSTLY LIKELY TO AFFECT THE |
| | SITE PLAN APPROVAL. |
| | |
| | DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION, |
| | COMMENTS: |
| | |
| | 1. THE COMMENT NUMBERING FROM THE PREVIOUS REVIEW HAS |
| | BEEN MAINTAINED IN THE REVIEW BELOW. THOSE COMMENTS |
| | THAT HAVE BEEN "ACKNOWLEDGED" AND CAN BE ADDRESSED WITH |
| | THE PERMIT APPLICATION HAVE BEEN OMITTED FROM THIS 2ND |
| | REVIEW. |
| | |
| | 2. LOCATION OF ACCESSIBLE PARKING SPACES. |
| | ORIGINAL COMMENT: GARAGE PARKING LEVEL PLANS A-107 AND |
| | A-108 SHOW REGULAR PARKING SPACES LOCATED CLOSER TO THE |
| | ELEVATORS THAN THE ACCESSIBLE PARKING SPACES IN THE |
| | FLAMINGO DRIVE PARKING GARAGE. PER SECTION 208.3 OF |
| | FLORIDA ACCESSIBILITY CODE, ACCESSIBLE PARKING SPACES |
| | ARE TO BE LOCATED ON THE SHORTEST POSSIBLE ROUTE OF |
| | TRAVEL FROM ADJACENT PARKING TO AN ACCESSIBLE ENTRANCE. |
| | THE DESIGN OF ACCESSIBLE PARKING SPACES SHALL COMPLY |
| | WITH SECTION 502 OF FLORIDA ACCESSIBILITY CODE. |
| | COMMENT ON REVISED PLANS: THE FLAMINGO DRIVE PARKING |
| | GARAGE IS SHOWN AS HAVING A TOTAL OF 270 PARKING SPACES |
| | (134 ON LEVEL 1 AND 136 ON LEVEL 2) BUT ONLY 4 |
| | ACCESSIBLE PARKING SPACES ARE SHOWN. PER SECTION 208.2 |
| | OF FLORIDA ACCESSIBILITY CODE, 7 ACCESSIBLE PARKING |
| | SPACES ARE REQUIRED. THERE ARE STILL REGULAR PARKING |
| | SPACES THAT ARE CLOSER TO THE ELEVATORS THAN THE |
| | PROPOSED ACCESSIBLE PARKING SPACES. PER SECTION 208.3 |
| | OF FLORIDA ACCESSIBILITY CODE, ACCESSIBLE PARKING |
| | SPACES ARE TO BE LOCATED ON THE SHORTEST POSSIBLE ROUTE |
| | OF TRAVEL FROM ADJACENT PARKING TO AN ACCESSIBLE |
| | ENTRANCE. THE DESIGN OF ACCESSIBLE PARKING SPACES SHALL |
| | COMPLY WITH SECTION 502 OF FLORIDA ACCESSIBILITY CODE. |
| | |
| | 3. VAN ACCESSIBLE PARKING SPACES. |
| | PLEASE INDICATE THE VAN ACCESSIBLE PARKING SPACES ON |
| | THE PLANS. THIS IS THE ORIGINAL COMMENT: PER SECTION |
| | 208.2.4 OF FLORIDA ACCESSIBILITY CODE, ONE IN EVERY SIX |
| | REQUIRED ACCESSIBLE SPACES (AT LEAST ONE) IN A PARKING |
| | STRUCTURE, SHALL BE ?VAN ACCESSIBLE? AND DESIGNED IN |
| | ACCORDANCE WITH SECTION OF 502 OF FLORIDA ACCESSIBILITY |
| | CODE (VERTICAL CLEARANCE NOT LESS THAN 98 INCHES AT |
| | SPACE AND VEHICULAR ACCESS ROUTE) |
| | |
| | 5. EGRESS FROM THEATER LOBBY. |
| | ORIGINAL COMMENT: SECOND FLOOR PLAN A-1.02 SHOWS A LONG |
| | NARROW STAIR FLIGHT LOCATED BETWEEN CINEMA 5 AND CINEMA |
| | 6 BUT THE STAIR DOES NOT SEEM TO LINE UP WITH THE |
| | LOCATION AND CONFIGURATION OF THE STAIR SHOWN ON FIRST |
| | FLOOR PLAN A1.01 OR MEZZANINE LEVEL PLAN A-1.01A. |
| | COMMENT ON REVISED PLANS: THE LONG NARROW STAIR LOCATED |
| | BETWEEN CINEMA 5 AND CINEMA 6 SEEMS TO PROVIDE EGRESS |
| | FROM THE PROJECTOR BOOTH CATWALK LEVEL ABOVE THE |
| | THEATER LOBBY, BUT THE PLANS DO NOT SEEM TO SHOW WHERE |
| | THAT STAIR COMES OUT (THE EXIT DISCHARGE) AT 1ST FLOOR |
| | LEVEL. THE STAIR IS STILL NOT SHOWN ON FIRST FLOOR PLAN |
| | A1.01 OR MEZZANINE LEVEL PLAN A-1.01A. |
| | |
| | 8. SEPARATE PERMITS REQUIRED. ALL APPLICABLE PERMITS |
| | AND SUB-PERMITS MUST BE OBTAINED BEFORE COMMENCING THE |
| | WORK. SEPARATE PERMITS, PLANS AND FEES, ARE REQUIRED |
| | FOR SIGNS, SWIMMING POOLS AND SPAS, GAS SYSTEMS, |
| | GENERATORS, FIRE ALARM SYSTEMS, FIRE SPRINKLER AND |
| | OTHER FIRE SUPPRESSION SYSTEMS, GREASE INTERCEPTORS, |
| | SITE LIGHTING, SITE LANDSCAPE, SITE IRRIGATION, ETC. |
| | |
| | 9. CONTRACTOR VEHICLE PARKING. PROPERTY OWNER AND |
| | CONTRACTOR SHALL MAKE ARRANGEMENTS FOR PARKING OF |
| | CONTRACTOR VEHICLES TO MINIMIZE THE IMPACT ON ALL |
| | NEIGHBORING PROPERTIES. |
| | |
| | 10. PROTECTION OF NEIGHBORING PROPERTY. PROPERTY OWNER |
| | AND CONTRACTOR SHALL PROTECT ALL NEIGHBORING PROPERTY, |
| | INCLUDING VEHICLES, FROM DAMAGE OR DIRT CAUSED BY THE |
| | CONSTRUCTION, AND SHALL NOTIFY THE OCCUPANTS OF |
| | NEIGHBORING PROPERTIES ABOUT ALL STAGES OF CONSTRUCTION |
| | THAT MAY AFFECT THE USE OF THEIR PROPERTY. |
| | |
| | 11. ART IN PUBLIC PLACES. THIS PROJECT WILL BE SUBJECT |
| | TO ART IN PUBLIC PLACES (AIPP) ASSESSMENT. FOR ADVICE |
| | ON THE PROVISION OF PUBLIC ARTWORK IN LIEU OF THE AIPP |
| | ASSESSMENT, CONTACT SYBILLE WELTER, ART IN PUBLIC |
| | PLACES COORDINATOR, AT (561) 822-1521, OR BY EMAIL: |
| | [email protected] |
| | |
| | ROBERT BROWN |
| | BUILDING OFFICIAL |
| | TEL: 561 805 6652 |
| | EMAIL: [email protected] |
| | |
| |
Print |