| Date |
Text |
| 2019-11-05 16:48:26 | ONGOING COMMENTS FROM PREVIOUS REVIEWS: |
| | |
| | 13. ONGOING. PALM TRAN HAS PERMITTED THE USE OF THE |
| | BROADSTONE BUS SHELTER, BUT IT WILL NEED A BACK |
| | INSTALLED. THE APPLICANT SHALL PROVIDE SOME |
| | ARCHITECTURAL RENDERINGS OF PROPOSED BACKING TO BE |
| | REVIEWED BY CITY STAFF. CAN BE A CONDITION OF APPROVAL |
| | FOR SITE PLAN. THE NEW BUS SHELTER WILL NEED TO BE IN |
| | OPERATION PRIOR TO CLOSING THE QUADRILLE SIDEWALK FOR |
| | ANY CONSTRUCTION. |
| | |
| | 19. ONGOING. IN ORDER TO COUNT TANDEM PARKING SPACES AS |
| | TWO SPACES, A RESTRICTIVE COVENANT SHALL BE REQUIRED |
| | FOR CONFIRMATION OF A VALET ATTENDANT IN CHARGE OF THE |
| | OPERATION OF THE PARKING FACILITY DURING ALL OPERATING |
| | HOURS. |
| | APPLICANT SHALL CONTINUE TO WORK WITH CITY LEGAL |
| | DEPARTMENT ON RESTRICTIVE COVENANT FOR VALET PARKING. |
| | THIS SHALL BE A CONDITION OF APPROVAL FOR SITE PLAN. |
| | |
| | 29. ONGOING. PLEASE PRESERVE THE EXISTING CEMENT CANOPY |
| | ON SITE, PER CITY HISTORIC PRESERVATION PLANNER. THIS |
| | COULD BE MAINTAINED WITHIN THE OPEN SPACE. |
| | CONVERSATION ONGOING WITH HISTORIC PRESERVATION |
| | DIVISION. SHALL BE A CONDITION OF APPROVAL. |
| | |
| | 33. PARTIALLY SATISFIED. PLEASE PROVIDE ADDITIONAL |
| | DETAIL OF ARCHITECTURAL TREATMENT MATERIALS ON BUILDING |
| | ON ELEVATION PLANS. |
| | PLEASE PROVIDE ADDITIONAL DETAIL OF THE ALUMINUM FRAME |
| | ON THE PARKING GARAGE ? IS IT FULLY OPEN? ANY |
| | ADDITIONAL SCREENING BEHIND THE FRAME? EXAMPLE WOULD BE |
| | BENEFICIAL. PLEASE PROVIDE AN EXAMPLE OF THE BRICK |
| | ACCENT, FIXED DECORATIVE SHUTTERS, DECORATIVE BRACKETS, |
| | ETC. THIS ARE REQUESTED FOR DAC REVIEW. (NEED IN TIME |
| | FOR DAC SUBMITTAL ? ON PLANS SUBMITTED NO LATER THAN |
| | 11/27) |
| | |
| | 36. PARTIALLY SATISFIED. PLEASE CHECK CRITERIA FOR FDOT |
| | SIGHT TRIANGLE FOR PROPOSED TREES AT STREET CORNERS. |
| | A TREE AT THE CORNER OF QUADRILLE AND DATURA IS STILL |
| | WITHIN THE SIGHT TRIANGLE. |
| | |
| | 38. NOT SATISFIED. PLEASE PROVIDE A HARDSCAPE PLAN WITH |
| | DETAILS OF PAVERS, SEATING, ETC. |
| | SOME HARDSCAPE DETAILS ARE NEEDED FOR DAC REVIEW OF |
| | PAVERS, SEATING, LANDSCAPE BED AREAS (ALONG DATURA |
| | STREET APPEARS TO HAVE BENCHES AROUND LANDSCAPE AREA), |
| | ETC. PLEASE PROVIDE WHAT YOU CAN; STAFF AND THE DAC |
| | MEMBERS REALIZE THESE MAY CHANGE WITH PERMITTING AND |
| | CONSTRUCTION. |
| | |
| | 39. SATISFIED. PLEASE SEE TABLE IV-7 FOR OPEN SPACE |
| | STANDARDS. CURRENTLY THE PASSAGEWAY PUBLIC OPEN TYPE IS |
| | REQUIRED. STAFF IS CURRENTLY REVIEWING THIS REQUIREMENT |
| | FOR APPLICABILITY FOR THIS SITE. |
| | CODE AMENDMENT UNDERWAY THAT WILL PERMIT UPGRADING |
| | PRIVATE OPEN SPACE TO PUBLIC OPEN SPACE IN SOME CASES |
| | WITHIN THE DMP. |
| | |
| | |
| | 44. NOT SATISFIED. PER SECTION 93-113, BICYCLE PARKING |
| | FOR THE PUBLIC SHALL BE PROVIDED AT A MINIMUM OF ONE |
| | SPACE PER EVERY 100 FEET OF STREET FRONTAGE. THE POST |
| | AND LOOP RACK IS RECOMMENDED FOR THE PUBLIC ROW. PLEASE |
| | INDICATE EXACT BICYCLE RACK DETAIL ON PLANS. |
| | STAFF CALCULATES THE REQUIRED PRIVATE BICYCLE PARKING |
| | TO BE 7 SPACES, WITH APPROXIMATELY 670 FEET OF ROW. |
| | ADDITIONALLY, THE LOCATION OF THE PUBLIC BICYCLE RACKS |
| | WITHIN THE PRIVATE OUTDOOR DINING AREA DOES NOT SATISFY |
| | REQUIREMENTS. PLEASE RELOCATE FOR A PUBLIC USE. |
| | |
| | 46. ONGOING. PLEASE INDICATE LOCATION OF PROPOSED |
| | UTILITIES INCLUDING THE BACKFLOW PREVENTER, FDC |
| | CONNECTION, FPL TRANSFORMER, ETC. STAFF RECOMMENDS |
| | LOCATING THE UTILITIES WITHIN THE BUILDING FOOTPRINT |
| | AND PROVIDING ACCESS TO UTILITY COMPANIES, TO KEEP OFF |
| | THE PUBLIC ROW. ALTERNATIVELY, UTILITIES CAN BE LOCATED |
| | ALONG THE ALLEY SIDE OF THE BUILDING. SUFFICIENT |
| | LANDSCAPE SCREENING IS REQUIRED WHEN UTILITIES ARE |
| | LOCATED OUTSIDE OF THE BUILDING AND WITHIN THE ROW. A |
| | MINIMUM OF 5 FOOT SIDEWALK CLEARANCE MUST BE MAINTAINED |
| | AT ALL LOCATIONS. |
| | SEE NEW COMMENT 94. PLACEMENT OF UTILITIES SHALL BE |
| | ONGOING THROUGH PLANNING AND PERMIT PROCESS, SUBJECT TO |
| | REVIEW BY ZONING, LANDSCAPE PLANNER, AND BUILDING |
| | DEPARTMENTS. THIS SHALL BE A SITE PLAN CONDITION OF |
| | APPROVAL. |
| | |
| | 48. NOT SATISFIED. THE MINIMUM FOOTCANDLE, AS MEASURED |
| | AT THE BACK EDGE OF THE CURB AND ONE FOOT ABOVE THE |
| | SIDEWALK IS 0.6 AND THE MAXIMUM IS 1.0 FOOTCANDLE. |
| | PLEASE ADJUST PHOTOMETRICS EXTENDING TO THE ROADWAY |
| | CENTERLINES AND PROVIDE DETAILS OF THE PROPOSED LIGHT |
| | FIXTURES AS NECESSARY. PLEASE COORDINATE WITH THE |
| | ENGINEERING DEPARTMENT TO USE THE CITY APPROVED LIGHT |
| | FIXTURE. A SPECIFIC FIXTURE IS REQUIRED FOR ALL ROW. |
| | THE PHOTOMETRIC PLAN DOES NOT MATCH THE SITE PLAN OR |
| | LANDSCAPE PLAN. THERE IS A LIGHT POLE PROPOSED WHERE A |
| | TREE IS PROPOSED ON THE CORNER OF DATURA AND QUADRILLE |
| | ON THE DATURA SIDE. PLEASE RELOCATE THE PROPOSED LIGHT |
| | POLE THAT IS IN THE CENTER OF THE SIDEWALK AT THE |
| | CORNER OF DATURA AND DIXIE. THE PLAN SHOWS A LIGHT POLE |
| | PROPOSED IN THE ON STREET PARKING ALONG DIXIE HIGHWAY. |
| | |
| | 65. PARTIALLY SATISFIED. PLEASE UPDATE THE ELEVATIONS |
| | TO INCLUDE LANDSCAPE PLANS. PLEASE INCLUDE ADDITIONAL |
| | ARCHITECTURAL MATERIAL LABELS INCLUDING GLASS, FAUX |
| | GLASS, STUCCO, ETC. |
| | PLEASE INCLUDE ADDITIONAL INFORMATION ? SEE COMMENT 33 |
| | |
| | 76. PLEASE INCLUDE ADA PARKING SPACES. SEE BUILDING |
| | COMMENTS. |
| | |
| | NEW COMMENTS NOVEMBER 5, 2019 |
| | 77. THERE IS A DISCREPANCY BETWEEN THE NUMBER OF BEDS |
| | FOR GROUP HOMES LISTED IN THE VEHICULAR PARKING AREA |
| | COMPARED TO THE UNIT PROGRAM DEVELOPMENT SUMMARY BED |
| | NUMBER. PLEASE UPDATE AS NECESSARY. |
| | 78. AS THE CODE AMENDMENT BEING PROCESSED TO PERMIT |
| | PRIVATE OPEN SPACE ON THE GROUND FLOOR LEVEL WILL TREAT |
| | THE OPEN SPACE AS PUBLIC, THE VARIANCE FOR THE SETBACK |
| | FROM DIXIE HIGHWAY IS NOT REQUIRED. PLEASE REMOVE FROM |
| | DATA TABLES AND FROM THE JUSTIFICATION STATEMENT (AND |
| | DAC APPLICATION IF NECESSARY) |
| | 79. PLEASE SHOW THE GROUND FLOOR PLAN ON SITE PLAN |
| | SHEET SP.1 |
| | 80. PLEASE CONSIDER THE ADDITION OF ARCHITECTURAL |
| | TREATMENT ON THE STAIRWAYS TO ALLEVIATE THE ACTIVE USE |
| | LINER VARIANCE. |
| | 81. THE NORTHERN PORTION OF FA?ADE ALONG DIXIE HIGHWAY |
| | THAT IS ADJACENT TO PARKING SPOTS CANNOT BE COUNTED |
| | TOWARDS ACTIVE USE. HOWEVER, THE PORTION OF THE DINING |
| | ROOM FA?ADE THAT IS SET FURTHER BACK BUT FRONTS DIXIE |
| | HIGHWAY CAN BE COUNTED. PLEASE ADJUST. |
| | 82. PLEASE ADD A CONTEXTUAL MASSING ELEVATION FOR |
| | DATURA STREET FACING NORTH FOR DAC SUBMITTAL (NO LATER |
| | THAN 11/27) |
| | 83. TRUNCATED DOME FOR ADA COMPLIANCE IS NOT APPARENT |
| | ON ANY PLANS. PLEASE CLARIFY INTERSECTION CROSSWALK |
| | CONNECTIVITY |
| | 84. ADA PARKING SPACES ARE REQUIRED EVEN FOR VALET |
| | OPERATION. PLEASE ADJUST AS NECESSARY. MUST BE DONE |
| | PRIOR TO DAC (PLANS CHANGED NO LATER THAN 11/27) |
| | 85. PLEASE ADJUST THE DROP OFF AREA ON DATURA STREET TO |
| | THE SIZE OF A PARALLEL PARKING SPACE (22 FEET) TO |
| | ACCOMMODATE THE REQUIRED SHADE TREE PER EVERY 30 FEET |
| | 86. PLEASE ADD A SHADE TREE TO THE SOUTH SIDE OF DIXIE |
| | HIGHWAY NEAR THE DIXIE AND DATURA INTERSECTION (REMOVE |
| | HOLLY TREES PER LANDSCAPE COMMENTS AND REPLACE WITH OAK |
| | TREES) |
| | 87. PLEASE REMOVE THE LOW WALL FROM THE BISTRO OUTDOOR |
| | AREA AS THIS AREA IS BEING CONSIDERED PUBLIC OPEN SPACE |
| | (IN TIME FOR DAC SUBMITTAL ? ON PLANS SUBMITTED NO |
| | LATER THAN 11/27) |
| | 88. PLEASE REMOVE REFERENCE TO ?PRIVATE TERRACE ALONG |
| | DATURA STREET? FROM THE SOUTH DIXIE HIGHWAY SIDE |
| | ELEVATION ON SHEET A-3.2 AS THIS IS BEING TREATED AS |
| | PUBLIC OPEN SPACE (IN TIME FOR DAC SUBMITTAL ? ON PLANS |
| | SUBMITTED NO LATER THAN 11/27) |
| | 89. PLEASE CONSIDER THE ADDITION OF COLOR INTO THE |
| | LANDSCAPE PALETTE ALONG DIXIE HIGHWAY AND QUADRILLE |
| | BOULEVARD |
| | 90. THERE IS AN AREA ADJACENT TO THE INTERIOR BICYCLE |
| | RACKS THAT IS SHOWN DIFFERENTLY ON THE SITE PLAN |
| | COMPARED TO CIVIL PLANS. PLEASE CLARIFY |
| | 91. CONSIDER A CORRIDOR OR DOOR FROM THE OUTSIDE TO |
| | ACCESS THE INTERIOR BICYCLE RACKS TO ELIMINATE THE NEED |
| | FOR CYCLISTS TO CROSS OVER THE GARAGE RAMP ENTRANCE. |
| | THE LOCATION OF THE RACKS DOES NOT WORK WELL FOR |
| | INGRESS AND EGRESS |
| | 92. PLEASE ADDRESS THE EXITING TRAFFIC POLE BOXES AT |
| | PROPERTY?S SOUTHEAST CORNER. PLEASE INCORPORATE INTO |
| | LANDSCAPE BED. |
| | 93. PLEASE INDICATE PROPOSED LOCATION OF BACKFLOW |
| | PREVENTER. PLEASE PLAN TO LOCATE WITHIN LANDSCAPE BED. |
| | 94. PLEASE ENSURE THAT GROUND MOUNTED FDC IS WITHIN A |
| | LANDSCAPE BED OR ALTERNATIVELY, MOUNT ON WALL. |
| | 95. PLEASE PROVIDE GROUND LEVEL 3D RENDERINGS FOR DAC |
| | APPLICATION (NO LATER THAN 11/27) ? INCLUDE LANDSCAPE |
| | AT PLANTING LEVEL. PLEASE INCLUDE DAY TIME RENDERING. |
| | 96. PLEASE NOTE, NEXT SITE PLAN RESUBMITTAL WILL HAVE A |
| | REQUIRED RESUBMITTAL FEE OF $300 (RESUBMITTAL FEE, |
| | CHARGED AFTER 1ST RESUBMITTAL) |
| | 97. THE STAIRWELL ALONG QUADRILLE BOULEVARD HAS A |
| | DOORWAY THAT OPENS INTO THE SIDEWALK AREA, WHICH DOES |
| | NOT WORK. THIS WILL NEED TO BE RECESSED. |
| | |
| | |
| | ELIZABETH LEVESQUE, AICP, URBAN DESIGN PLANNER |
| | [email protected] |
| | 561 822 1426 |
| |
Print |