| 2019-08-26 17:51:48 | CASE NO. PB 950 OOOOO - 1ST RESUBMITTAL REVIEW |
| | HIBISCUS TOWER |
| | 575 SOUTH ROSEMARY AVENUE |
| | |
| | - CONTACT ERIC SCHNEIDER @ (561) 822-1446 |
| | |
| | - PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN |
| | WRITTEN FORMAT. |
| | |
| | - WHEN RESUBMITTING, PLEASE PROVIDE A MINIMUM OF ELEVEN |
| | (11) PAPER COPIES AND AN ELECTRONIC COPY IN .PNG FORMAT |
| | OF ALL PLANS. PLEASE NOTE THAT CHANGES ON THE |
| | RESUBMITTED PLANS OR THE SUBMITTAL OF INFORMATION/PLANS |
| | TO ADDRESS THE COMMENTS MAY RESULT IN ADDITIONAL |
| | COMMENTS. |
| | |
| | - THE COMMENTS SHALL BE SUFFICIENTLY ADDRESSED AND |
| | SUBMITTED TO THE PLANNING DIVISION BY 5 PM ON FRIDAY, |
| | AUGUST 30, 2019, TO BE ELIGIBLE TO BE SCHEDULED FOR THE |
| | OCTOBER 15, 2019 PLANNING BOARD MEETING. |
| | |
| | - PLEASE NOTE THAT SINCE PREVIOUSLY-ISSUED COMMENTS |
| | WERE NOT BE SUFFICIENTLY ADDRESSED, THE APPLICANT WILL |
| | BE ASSESSED A RESUBMITTAL FEE. SUCH FEE IS 20% OF THE |
| | ORIGINAL APPLICATION FEE ($600). |
| | |
| | - PUBLIC HEARING NOTIFICATION SIGNAGE SHALL BE POSTED |
| | IN ACCORDANCE WITH THE REQUIREMENTS OF SECTION |
| | 94-39(I)(5) OF THE ZONING AND LAND DEVELOPMENT |
| | REGULATIONS. |
| | |
| | 1) THE SCALE BAR ON SHEET A0.04.2 PRINTED MULTIPLE |
| | SCALES AND IS UNREADABLE. THIS OCCURS ON A FEW SHEETS, |
| | SO PLEASE CORRECT. |
| | |
| | 2) REPEAT COMMENT: PROVIDE THE DIMENSION LINE SHOWING |
| | THE FULL HEIGHT OF THE PODIUM, PLUS THE HIGHEST POINT |
| | OF THE HEIGHT ENCROACHMENT ON THE ELEVATION PLANS. THE |
| | PODIUM HEIGHT DIMENSION WAS NOT PROVIDED FOR THE |
| | HIBISCUS STREET FRONTAGE. THE WESTERN PORTION OF THE |
| | PODIUM ALONG HIBISCUS STREET (PRIMARILY THE PRIVATE |
| | TERRACE) SCALES TO EXCEED 60 FEET AND ADDITIONALLY HAS |
| | A VERTICAL ENCROACHMENT (RAILING) EXCEEDING THE 60 FOOT |
| | ALLOWANCE. |
| | |
| | 3) UPDATED COMMENT: THANK YOU FOR PROVIDING ADDITIONAL |
| | INFORMATION REGARDING THE FACADE ARTICULATION. BASED ON |
| | THE RESUBMITTED INFORMATION, STAFF HAS IDENTIFIED THE |
| | FOLLOWING ITEMS WHICH STILL MUST BE PROVIDED: |
| | |
| | A. THE AMOUNT OF GROUND FLOOR TRANSPARENCY PROVIDED |
| | ALONG SOUTH ROSEMARY AVENUE AND HIBISCUS STREET IS NOT |
| | LISTED ON THE PLANS. THE ONLY CALCULATION LISTED IS HOW |
| | MUCH IS REQUIRED. |
| | B. THE AMOUNT OF FENESTRATION FOR THE PODIUM AND THE |
| | TOWER IS NOT LISTED ON THE PLANS. ONLY A STATEMENT THAT |
| | THE FENESTRATION EXCEEDS 15% IS LISTED ON THE PLANS. |
| | C. THE TAG LINES FOR THE WEST ELEVATIONS FOR MATERIAL |
| | 01 AND 02 SEEM TO POINT TO THE WRONG MATERIAL. |
| | D. PLEASE CONSIDER ADDITIONAL WINDOWS OVERLOOKING THE |
| | OUTDOOR SEATING AREA FROM THE GROUND LEVEL RETAIL AND |
| | UPPER LEVEL OFFICE. |
| | |
| | 4) UPDATED COMMENT: PLANAR BREAKS ARE REQUIRED FOR ALL |
| | LEVELS OF THE PODIUM. THE PLANS DO NOT CLEARLY SHOW |
| | EVIDENCE THAT THIS OCCURS. |
| | |
| | A. THE SOUTH ROSEMARY AVENUE FRONTAGE (GROUND FLOOR) |
| | ADDED DOORWAYS THAT ARE BEING COUNTED TOWARD MEETING |
| | THE MINIMUM LINEAR FEET OF PLANAR BREAK. IN ORDER FOR |
| | DOORWAYS TO COUNT TOWARD MEETING THIS REQUIREMENT, THE |
| | DOORWAY RECESS (THE PLANER BREAK) NEEDS TO CONTINUE |
| | FROM GRADE FOR THE FULL HEIGHT OF THE GROUND FLOOR. THE |
| | DRAWINGS DO NOT CLEARLY INDICATE THAT THE DOORWAYS |
| | EXTEND THE FULL HEIGHT OF THE GROUND FLOOR, AND IN FACT |
| | IT APPEARS THAT THE DOORWAYS ARE NOT THE FULL HEIGHT OF |
| | THE GROUND FLOOR. |
| | B. ON THE SOUTH ROSEMARY AVENUE FRONTAGE (2ND AND 3RD |
| | FLOOR), WHILE THE OUTDOOR SEATING RECESS AND THE OFFICE |
| | TERRACE COMBINE TO MEET THE MINIMUM REQUIRED PLANAR |
| | BREAK AND THE RETAIL ONE CONTINUES TO EXCEED THIS |
| | REQUIREMENT, PLEASE CHECK THE SECTION DRAWING ON SHEET |
| | A3.01 AS IS APPEARS THAT THE PROPOSED PLANAR BREAK IS |
| | NOT DEPICTED ACCURATELY. |
| | C. THE HIBISCUS STREET FRONTAGE (2ND FLOOR) ADDED A |
| | RECESS THAT IS BEING COUNTED TOWARD MEETING THE MINIMUM |
| | LINEAR FEET OF PLANAR BREAK. IN ORDER FOR RECESS TO |
| | COUNT TOWARD MEETING THIS REQUIREMENT, THE IT (THE |
| | PLANER BREAK) NEEDS TO CONTINUE THE FULL HEIGHT OF THE |
| | 2ND FLOOR. THE DRAWINGS DO NOT CLEARLY INDICATE THAT |
| | THE RECESS EXTENDS THE FULL HEIGHT OF THE 2ND FLOOR. |
| | |
| | 5) UPDATED COMMENT: STAFF HAS REVIEWED THE REVISED |
| | ACTIVE USE DIAGRAMS FOR THE SOUTH ROSEMARY AVENUE |
| | FRONTAGE AND HAS THE FOLLOWING COMMENTS: |
| | |
| | A. THE MAINTENANCE OFFICE ADDED TO THE 3RD FLOOR DOES |
| | NOT APPEAR TO HAVE ADA ACCESSIBILITY. PLEASE DESCRIBE |
| | HOW THIS SPACE WILL MEET BUILDING CODE REQUIREMENTS. IF |
| | THIS ROOM CANNOT BE CONSTRUCTED AS SHOWN ON THE PLANS, |
| | THEN IT WILL CAUSE ISSUES DURING THE PERMITTING |
| | PROCESS. |
| | B. THE ZONING AND LAND DEVELOPMENT REGULATIONS REQUIRE |
| | THAT ACTIVE USES HAVE A DIRECT VIEW TO THE ADJACENT |
| | STREETS OR PUBLIC OPEN SPACE. THIS DOES NOT OCCUR FOR |
| | THE 2ND STORY RETAIL ALONG SOUTH ROSEMARY AVENUE OR |
| | HIBISCUS STREETS SINCE THE PROPOSED FLUTED CHANNEL |
| | GLASS IS NOT TRANSPARENT. ADDITIONALLY, THE TWO |
| | MAINTENANCE OFFICES (BOTH COUNTED AS ACTIVE USE) HAVE |
| | NO DIRECT VIEW TO THE ADJACENT STREETS |
| | |
| | 6) UPDATED COMMENT: STAFF HAS REVIEWED THE PUBLIC OPEN |
| | SPACE COMPLIANCE TABLE FOR THE OUTDOOR SEATING AREA |
| | ALONG SOUTH ROSEMARY AVENUE AND NOTED THAT IT |
| | INCORRECTLY INCLUDES THE SQUARE FOOTAGE FOR THE AREA |
| | UNDER THE 2ND AND 3RD FLOORS OF THE BUILDING. THIS AREA |
| | DOES NOT MEET THE DEFINITION OF OVERHEAD COVER, WHICH |
| | INCLUDES AWNINGS, CANOPIES, COLONNADES, PERGOLAS, |
| | TRELLISES OR OTHER SIMILAR STRUCTURES. THE STAFF |
| | CALCULATES THE ACTUAL OPEN SPACE AREA AS APPROXIMATELY |
| | 937 SF AND IT APPEARS THAT THE OPEN SPACE MINIMUMS HAVE |
| | BEEN MET AS SHOWN. UPDATE THE TABLE WITH THE ACCURATE |
| | OPEN SPACE AREA AND CORRESPONDING COMPLIANCE |
| | VERIFICATION. NOTE: THE LANDSCAPE UNDER THE BUILDING |
| | MAY NOT BE INCLUDED IN THE PROVIDED LANDSCAPE |
| | CALCULATION. |
| | |
| | 7) UPDATED COMMENT: STAFF HAS REVIEWED THE PRIVATE OPEN |
| | SPACE AND HAS THE FOLLOWING COMMENTS: |
| | |
| | A. LEVEL 4 OPEN SPACE AREA B DOES NOT COMPLY WITH THE |
| | MINIMUM PUBLIC RIGHT-OF-WAY ABUTMENT TO BE CONSIDERED A |
| | TERRACE. THIS PRIVATE OPEN SPACE IS MORE THAN 60 FEET |
| | FROM THE SOUTH ROSEMARY AVENUE PUBLIC RIGHT-OF-WAY AND |
| | THE SEPARATION INCLUDES MECHANICAL ROOMS AND THE |
| | CHILLER ENCLOSURES. PRIVATE OPEN SPACE AT THIS LOCATION |
| | CAN ONLY BE A ROOFTOP GARDEN. PLEASE UPDATE THE TABLE |
| | AND PLANS ACCORDINGLY. |
| | B. LEVEL 4 OPEN SPACE AREA C DOES NOT COMPLY WITH THE |
| | MINIMUM PUBLIC RIGHT-OF-WAY ABUTMENT TO BE CONSIDERED A |
| | TERRACE. THE WEST SIDE OF THE BUILDING ABUTS AN ACCESS |
| | EASEMENT, NOT A PUBLIC RIGHT-OF-WAY. PRIVATE OPEN SPACE |
| | AT THIS LOCATION CAN ONLY BE A ROOFTOP GARDEN. PLEASE |
| | UPDATE THE TABLE AND PLANS ACCORDINGLY. |
| | C. LEVEL 5 OPEN SPACE INCORRECTLY CALCULATES THE AMOUNT |
| | OF PUBLIC RIGHT-OF-WAY ABUTMENT. ONLY THE 96 FOOT 9 |
| | INCH SECTION OF THE TERRACE MAY COUNT (AS PREVIOUSLY |
| | STATED THE ACCESS EASEMENT DOES NOT MEET THE PUBLIC |
| | RIGHT-OF-WAY REQUIREMENT). WHILE THE MINIMUM 20% HAS |
| | BEEN MET, THE TABLE NEEDS TO BE UPDATED ACCORDINGLY. |
| | NOTE: THE SQUARE FOOTAGE ASSOCIATED WITH THIS PRIVATE |
| | OPEN SPACE MAY BE AFFECTED BY CORRECTING THE RAILING |
| | HEIGHT FROM COMMENT #2. |
| | |
| | 8) UPDATED COMMENT: PLEASE DESCRIBE HOW THE LEVEL 4 |
| | ROOFTOP GARDEN WILL BE USED (ACCESSED) BY THE RESIDENTS |
| | OR THE OFFICE TENANTS. |
| | |
| | 9) PUBLIC OPEN SPACE - PASSAGE REQUIREMENTS |
| | |
| | A. UPDATED COMMENT: A PASSAGEWAY IS REQUIRED TO CONNECT |
| | TWO OR MORE PUBLIC RIGHTS-OF-WAY OR PUBLIC SPACES. THE |
| | ACCESS EASEMENT ON THE WEST SIDE OF THE BUILDING IS NOT |
| | A PUBLIC RIGHT-OF-WAY SO THIS SIDE OF THE PASSAGEWAY |
| | NEEDS TO TERMINATE AT A PUBLIC SPACE (GENERALLY THE |
| | AREA UNDER THE BUILDING ALONG THE ACCESS EASEMENT). IN |
| | ORDER FOR THIS AREA TO BE CLASSIFIED AS PUBLIC SPACE, |
| | IT WILL NEED A PUBLIC ACCESS EASEMENT RECORDED FOR IT |
| | AS WELL AS HAVE SEATING INSTALLED. THE PASSAGEWAY WILL |
| | END AT THE COVERED PUBLIC SPACE. |
| | B. REPEAT COMMENT: PROVIDE THE DIMENSIONS FOR THE |
| | NARROW POINTS SHOWN IN THE PASSAGEWAY. EX. BETWEEN THE |
| | BUILDING WALLS, THE EDGE OF THE LANDSCAPE AREAS AND THE |
| | COLUMNS. THESE ALL APPEAR TO BE CHOKE POINTS IN THE |
| | PASSAGEWAY. |
| | C. UPDATED COMMENT: THE WESTERN PORTION OF THE |
| | PASSAGEWAY IS COVERED BY THE UPPER RESIDENTIAL STORIES, |
| | INCLUDING BALCONIES. THIS AREA DOES NOT MEET THE |
| | DEFINITION OF OVERHEAD COVER, WHICH INCLUDES AWNINGS, |
| | CANOPIES, COLONNADES, PERGOLAS, TRELLISES OR OTHER |
| | SIMILAR STRUCTURES, BUT DOES NOT INCLUDE AN AREA THAT |
| | HAS THE UPPER STORIES OF THE BUILDING. THE 1,460 SQUARE |
| | FEET OF COVERED AREA MAY NOT BE COUNTED TOWARD MEETING |
| | THE OPEN SPACE REQUIREMENT. UPDATE ALL TABLES |
| | ACCORDINGLY. |
| | D. UPDATED COMMENT: THE OPEN SPACE MEASUREMENTS FOR THE |
| | PASSAGEWAY MAY NOT INCLUDE AREAS WITHIN THE MINIMUM |
| | SETBACK. PROVIDE THE REQUIRED NFPA SETBACK DIMENSION |
| | FOR THE WEST SIDE OF THE 477 SOUTH ROSEMARY BUILDING |
| | WHERE IT ABUTS THE PASSAGEWAY. THIS SETBACK AREA MAY |
| | NOT BE COUNTED TOWARD MEETING THE PUBLIC OPEN SPACE |
| | SQUARE FOOTAGE REQUIREMENT. ALTERNATIVELY, SINCE THE |
| | PLANS STATE THAT THE OPENINGS WILL BE PROTECTED, |
| | PROVIDE THE METHOD FOR THIS PROTECTION THAT WOULD |
| | PERMIT THE NEW 575 SOUTH ROSEMARY BUILDING TO BE BUILT |
| | TO THE PROPERTY LINE. NOTE: THE SQUARE FOOTAGE FOR THE |
| | EGRESS WALKWAY BEHIND THE TWO DOORS ON THE WEST SIDE OF |
| | 477 SOUTH ROSEMARY AVENUE CANNOT BE INCLUDED IN THE |
| | PASSAGEWAY SINCE IT IS NOT PART OF THE PASSAGEWAY. |
| | UPDATE ALL TABLES ACCORDINGLY. |
| | |
| | 10) UPDATED COMMENT: PROVIDE DIMENSION ON THE ELEVATION |
| | DRAWINGS FOR THE PROJECTING ELEMENTS, WHICH INCLUDE THE |
| | BALCONIES, BOTH RESIDENTIAL AND COMMERCIAL, THE AWNINGS |
| | (EX. KEYNOTE 03 ON THE NORTH ELEVATION - TEMPERED GLASS |
| | AND ALUMINUM AWNING). |
| | |
| | 11) NEW COMMENT: PROVIDE A SAMPLE FLOOR PLAN LEVEL |
| | WHICH SHOWS THE SHORT BALCONIS AND ON THAT SHOWS THE |
| | LONG BALCONIES FOR THAT SPECIFIC FLOOR. |
| | |
| | 12) UPDATED COMMENT: THE NET AREA DRAWINGS FOR THE |
| | RESTAURANT, RETAIL AND OFFICE USES MUST INCLUDE THE |
| | FOLLOWING AREAS AND ALL THE PARKING TABLES NEED TO BE |
| | UPDATED ACCORDINGLY: |
| | |
| | A. RESTAURANT KITCHEN AND STORAGE - THESE AREAS ARE NOT |
| | INCLUDED IN THE EXEMPTIONS LISTED IN THE NET INTERIOR |
| | AREA DEFINITION OF SECTION 94-109 OF THE ZONING AND |
| | LAND DEVELOPMENT REGULATIONS. |
| | B. DOCK MANAGER OFFICE - THE LOADING DOCKS SERVICE BOTH |
| | THE RESIDENTIAL AND THE NON-RESIDENTIAL COMPONENTS OF |
| | THE BUILDING, SO DOCK MANAGER'S OFFICE NEEDS TO BE |
| | INCLUDED IN THE PARKING CALCULATION. |
| | C. SHOP BY THE LOADING DOCKS - IF THE SHOP ONLY |
| | SERVICES THE RESIDENTIAL TOWER, THEN IT IS EXEMPTED; |
| | HOWEVER, BY ITS LOCATION, IT APPEARS TO SERVICE THE |
| | ENTIRE BUILDING AND MUST BE INCLUDED IN THE NET AREA. |
| | D. MAINTENANCE OFFICES ON LOFT LEVEL 3 - MAINTENANCE |
| | OFFICES SERVING THE NON-RESIDENTIAL PORTION OF THE |
| | BUILDING MUST BE INCLUDE IN THE NET AREA. |
| | E. RETAIL STORAGE - THESE AREAS ARE NOT INCLUDED IN THE |
| | EXEMPTIONS LISTED IN THE NET INTERIOR AREA DEFINITION |
| | SECTION 94-109 OF THE ZONING AND LAND DEVELOPMENT |
| | REGULATIONS. |
| | |
| | 13) UPDATED COMMENT: THE SHARED PARKING MAY ONLY BE |
| | USED IF THERE ARE NO PARKING SPACES DESIGNATED FOR A |
| | PARTICULAR USE. THE RESPONSE STATES THAT THERE ARE NO |
| | DESIGNATED PARKING SPACES WITHIN GARAGE D, WHEN IN FACT |
| | THERE IS AT LEAST ONE AREA THAT IS GATED OFF FOR THE |
| | USE OF THE GARDENS RESIDENTS. HOW WILL OPERATIONALLY |
| | THE PARKING BE PROVIDED FOR THE USERS OF THE 575 SOUTH |
| | ROSEMARY BUILDING- EX: WILL THE RESIDENTIAL TENANTS |
| | HAVE AN AREA THAT IS DESIGNATED FOR "575 TOWER |
| | RESIDENTIAL PARKING ONLY"? IF THIS IS THE CASE, THEN |
| | THE SHARED PARKING MAY NOT BE USED. IF THERE WILL BE NO |
| | DESIGNATED PARKING, THEN THE LEVEL III SITE PLAN |
| | APPROVAL WILL CONTAIN THE DEVELOPMENT REGULATION THAT |
| | NO LEASES CAN INCLUDE DESIGNATED PARKING IN THE D |
| | GARAGE AND THAT NO BARRIERS MAY BE INSTALLED IN THE |
| | GARAGE TO CREATE SEPARATED PARKING AREAS FOR SPECIFIC |
| | TENANTS. |
| | |
| | 14) UPDATED COMMENT: THE RECENT PARKING TABLE PROVIDED |
| | BY JORDAN RATHLEV SHOWS 724 PARKING SPACES AVAILABLE IN |
| | GARAGE D. THIS TABLE NEEDS TO INCLUDE A SUB TABLE |
| | SHOWING HOW THE 724 PARKING SPACES (OR AS MODIFIED BY |
| | THE BUILDING DIVISION ADA COMMENT) ARE ALLOCATED TO THE |
| | 575 SOUTH ROSEMARY AVENUE USERS (379 SPACES IF NOT |
| | RESERVED), THE GARDENS RESIDENCES (33 + 2 GUEST), 477 |
| | SOUTH ROSEMARY AVENUE (RETAIL AND OFFICE - DO ANY |
| | OFFICE USERS HAVE RESERVED SPACES?), AND DESIGNATED |
| | VALET. NOTE: THE PARKING AVAILABILITY TABLE INDICATES |
| | THAT THERE IS EXCESS CAPACITY THROUGHOUT THE ENTIRE |
| | CITYPLACE CPD, BUT STAFF IS TRYING TO VERIFY THAT |
| | GARAGE D IS NOT OVER CAPACITY. |
| | |
| | 15) UPDATED COMMENT: THE TWO LOCATIONS WHERE THE |
| | PEDESTRIAN CROSSING OF THE ACCESS EASEMENT NEED TO BE A |
| | DIFFERENT PAVING MATERIAL THAN THE ACCESS EASEMENT |
| | SURFACE SO THAT IT IS A VISUAL CLUE TO DRIVERS TO SLOW |
| | DOWN. THIS CURRENTLY OCCURS THROUGH THE USE OF THE |
| | EXISTING PAVER CROSSWALK, WHICH IS STAFF'S PREFERRED |
| | OPTION. RAISED CROSSWALKS (EQUAL TO CURB LEVEL) SHOULD |
| | BE EXPLORED. |
| | |
| | 16) NEW COMMENT: THE SIDEWALK AT THE NORTHWEST CORNER |
| | OF THE TOWER INCLUDES A LANDSCAPE BED TO THE EDGE OF |
| | THE BUILDING WHICH NARROWS THE SIDEWALK TO FIVE (5) |
| | FEET IN WIDTH. THE LANDSCAPE BED NEEDS TO BE SHORTENED |
| | SO THAT THE SIDEWALK AT THIS BLIND CORNER IS WIDER TO |
| | PREVENT SITUATIONS WHERE SOMEONE NEEDS TO STEP INTO THE |
| | ALLEY TO PASS IN OPPOSITE DIRECTIONS. |
| | |
| | 17) UPDATED COMMENT: STAFF HAS REVIEWED THE PROPOSED |
| | RESIDENTIAL TOWER VALET PLAN AND DOES NOT SUPPORT THE |
| | USE OF FERN STREET AND SOUTH ROSEMARY AVENUE TO RETURN |
| | THE VEHICLES. THIS PUTS ADDITIONAL VEHICLE TRIPS ON |
| | THESE TWO STREETS. AN ALTERNATIVE VALET PICK-UP IS |
| | REQUIRED. WHERE IS THE VALET AREA IN THE GARAGE? |
| | |
| | 18) UPDATED COMMENT: THE PROPOSED OFFICE VALET PLAN IS |
| | NOT CLEAR (THE BLUE DASHED LINE STOPS ON FERN STREET. |
| | IT APPEARS THE INTENT IS TO HAVE THE VALETS DRIVE THE |
| | CARS AROUND THE BLOCK AND USE FERN STREET, SOUTH |
| | ROSEMARY AVENUE AND/OR SAPODILLA AVENUE. STAFF DOES NOT |
| | SUPPORT THE USE OF THESE STREETS FOR THE VALET AS THIS |
| | PUTS ADDITIONAL VEHICLE TRIPS ON THESE ROADWAYS. AN |
| | ALTERNATIVE IS TO HAVE THE VALETS USE ONE OF THE |
| | SERVICE AREA SPACES AS A TURNAROUND SPACE SO THEY CAN |
| | GET THE GARAGE WITHOUT USING THE STREET NETWORK. |
| | |
| | 19) REPEAT COMMENT: PROVIDE THE PASSAGEWAY BICYCLE PAD |
| | AND RACK DETAIL AND THE DIMENSIONS ON THE PLANS. THEY |
| | DO NOT APPEAR TO MEET CODE REQUIREMENTS. NOTE: THE |
| | BICYCLE PARKING AREA ALONG THE PEDESTRIAN PASSAGE HAS 6 |
| | RACKS, NOT 3 AS LISTED ON THE PLANS. |
| | |
| | 20) REPEAT COMMENT: PROVIDE BICYCLE RACKS ALONG |
| | ROSEMARY FOR THE RETAIL CUSTOMERS. THE HIBISCUS AND |
| | ROSEMARY RECONSTRUCTION PLANS DO NOT SHOW ANY BICYCLE |
| | RACKS ADJACENT TO 575 SOUTH ROSEMARY. |
| | |
| | 21) UPDATED COMMENT: PROVIDE GREEN ROOF DETAILS FOR |
| | LEVELS 4 AND 5 AND THE TOWER ROOF. NOTE: IN ACCORDANCE |
| | WITH THE DEVELOPMENT REGULATIONS, THE LEVEL 4 AND 5 AND |
| | TOWER ROOF AREA THAT DO NOT INCLUDE THE MECHANICAL AND |
| | SKYLIGHT AREAS MUST HAVE EITHER GREEN ROOF OR SOLAR. IF |
| | SOLAR IS USED THIS NEEDS TO BE SHOWN. THE PLANS NEED TO |
| | FACTOR THIS IN NOW. |
| | |
| | 22) UPDATED COMMENT: PLEASE TURN ON THE FOREGROUND |
| | BUILDINGS ON THE NORTHWEST AND SOUTHWEST RENDERINGS ON |
| | SHEET R0.01. |
| | |
| | 23) REPEAT COMMENT: PROVIDE A SHADOW STUDY. --- STAFF |
| | HAS NOT SEEN A SHADOW STUDY AND THE DISC WAS NOT |
| | INCLUDED WITH THE RESUBMITTAL. |
| | |
| | 24) REPEAT COMMENT: THE PHOTOMETRIC PLAN SHOWS LIGHTING |
| | LEVELS AT THE CURB IN EXCESS OF THE PERMITTED ONE FOOT |
| | CANDLE. ---- RESUBMITTED SHEET E-0.1 STILL SHOWS LIGHT |
| | LEVELS AT THE CURB EXCEEDING ONE FOOTCANDLE. |
| | |
| | 25) REPEAT COMMENT: WHAT IS THE CONSTRUCTION PHASING |
| | PLAN FOR THE BUILDING, ROSEMARY AND THE ALLEY? WILL THE |
| | HIBISCUS RIGHT-OF-WAY, INCLUDING THE SIDEWALK, BE |
| | COMPLETED PRIOR TO THE CONSTRUCTION OF THE BUILDING? |
| | HOW WILL ACCESS BE PROVIDED TO THE TOWNHOUSES AND THE |
| | SERVICE TO 477 SOUTH ROSEMARY DURING CONSTRUCTION? ---- |
| | THE RESPONSE PRESENTED DOES NOT ADEQUATELY ADDRESS THE |
| | QUESTION. |
| | |
| | 26) REPEAT COMMENT: EXPLAIN THE BAR IN THE RESIDENTIAL |
| | LOBBY AREA. WHO DOES THIS SERVE? WHAT DOES IT SERVE? |
| | --- THE RESPONSE PRESENTED DOES NOT ADDRESS THE |
| | QUESTION. IF THIS IS A BAR, THAT IN ANYWAY COULD SERVE |
| | THE PUBLIC, THEN YOU HAVE A NON-RESIDENTIAL USE HERE. |
| | |
| | 27) UPDATED COMMENT: RESOLUTION 304-18 REQUIRES THAT |
| | THE ROOFTOP RAINWATER IS RETAINED ON-SITE AND IF NOT |
| | USED THEN IT HAS ON-SITE INFILTRATION. USING AN |
| | EXFILTRATION TRENCH TO DISCHARGE THE WATER OFF-SITE IS |
| | NOT PERMITTED. DESCRIBE HOW THE ROOFTOP RAINWATER WILL |
| | BE STORED ON-SITE. THE METHOD MAY IMPACT THE SITE PLAN. |
| | THE PAVING AND DRAINAGE PLAN DOES NOT SEEM TO COVER |
| | THIS REQUIREMENT. |
| | |
| | 28) UPDATED COMMENT: RESOLUTION 304-18 REQUIRES THAT |
| | THE PLAZA AREAS OF THE SITE RETAIN THE STORMWATER |
| | ON-SITE. IT APPEARS THAT THE PLAZA AREA ALONG SOUTH |
| | ROSEMARY AVENUE IS DESIGNED TO FLOW OFF-SITE. |
| | |
| | CONDITION: THE AC UNITS MOUNTED ON RACKS ON THE WEST |
| | BUILDING WALL OF 477 SOUTH ROSEMARY MUST BE REMOVED |
| | PRIOR TO THE CONSTRUCTION OF THE 575 SOUTH ROSEMARY |
| | BUILDING. |
| | |
| | CONDITION: WAYFINDING SIGNS ARE REQUIRED TO DIRECT |
| | PEDESTRIANS FROM THE GARAGE TO THE OFFICE, RESIDENTIAL |
| | AND RETAIL ENTRANCES. |
| | |
| |