2019-08-16 14:31:49FROM: RAY CARANCI, LANDSCAPE PLANNER 561-822-1462
 PROJECT: 575 ROSEMARY (MACY?S) Z19050019
 AUGUST 16, 2019
 I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND
 PROVIDE THE FOLLOWING COMMENTS:
  
 1. MAKE THE FOLLOWING CORRECTIONS TO THE TREE
 DISPOSITION PLAN:
 ? SATISFIED. THE WASHINGTONIA PALMS ARE CATEGORY 4,
 CANOPY VALUE IS 50 SQ FT.
 ? PARTIALLY SATISFIED. PROVIDE THE TOTAL SQUARE FOOTAGE
 OF MITIGATION FOR ALL TREES AND PALMS PROPOSED TO BE
 REMOVED.
 ? PARTIALLY SATISFIED. PROVIDE THE MITIGATION VALUES BY
 CATEGORY FOR THE PROPOSED STREETSCAPE TREES AND PALMS.
 SEE BELOW.
  
 2. NOT SATISFIED. THE STREETSCAPE CAN BE IMPROVED TO
 ACCOMPLISH THE INTENT OF THE CODE SECTION 94-113. THE
 COCONUT PALMS AND DATE PALMS MAY BE USED, BUT NOT AS
 COUNTING TOWARD THE TREE REQUIREMENT AT THE MAXIMUM 30
 FOOT SPACING. THERE ARE ALSO CONFLICTS WITH PROPOSED
 AWNING AND STREET TREES.
 PLANNING STAFF HAS NOT REVIEWED OR APPROVED THE
 STREETSCAPE PLANS FOR THE AREAS ADJACENT TO THIS
 PROJECT. PROVIDE THE 100% PLANS FOR REVIEW.
 3. NOT SATISFIED. REQUIRED STREET TREES MUST MEET THE
 20 FOOT HEIGHT REQUIREMENT AT INSTALLATION. LIST
 OVERALL HEIGHT ON PLANT LIST.
 PLANNING STAFF HAS NOT REVIEWED OR APPROVED THE
 STREETSCAPE PLANS FOR THE AREAS ADJACENT TO THIS
 PROJECT. PROVIDE THE 100% PLANS FOR REVIEW.
  
 4. NOT SATISFIED. SECTION 94-448 (D)(3) REQUIRES NATIVE
 TREES IN GOOD CONDITION TO BE PRESERVED ON SITE OR
 RELOCATED. SUBMIT THE REASON THE TWO EXISTING LIVE OAK
 TREES CANNOT BE RELOCATED OR USED IN THE PROPOSED
 STREETSCAPE.
 PLANNING STAFF HAS NOT REVIEWED OR APPROVED THE
 STREETSCAPE PLANS FOR THE AREAS ADJACENT TO THIS
 PROJECT. PROVIDE THE 100% PLANS FOR REVIEW.
  
  
 5. SATISFIED. PUBLIC AND PRIVATE OPEN SPACE AREAS SHOWN
 ON SHEET A0.05 MUST BE BROKEN DOWN TO SHOW THE REQUIRED
 VEGETATED AREA AND ANY TREE CANOPY REQUIREMENT FOR EACH
 AREA. PASSAGEWAY LESS THAN 7500 SQ FT REQUIRE ZERO ANY
 OF EITHER. TERRACE REQUIRES 20% MINIMUM VEGETATED AREA.
 ROOFTOP GARDEN REQUIRES 30% VEGETATED AREA AND 20% TREE
 CANOPY. TREE CANOPY VALUES CAN BE FOUND IN SECTION
 94-109 TABLE IV-8.
  
 6. SATISFIED. AREA LISTED AS POOL DECK ON LEVEL 3 IS
 NOT AN OPEN SPACE TYPE. CLASSIFY AS A PERMITTED PRIVATE
 OPEN SPACE TYPE (ROOFTOP GARDEN?) AND SHOW
 REQUIREMENTS.
  
 7. SATISFIED. ADD COLUMNS FOR NATIVE PLANTS AND DROUGHT
 TOLERANCE/ WATER USAGE TO THE PLANT LIST SO THAT
 FLORIDA FRIENDLY POINTS CAN BE SUBSTANTIATED.
  
 8. SATISFIED. TRA IS MISSING FROM THE PLANT LIST.
  
 9. PARTIALLY SATISFIED. SHOW LOCATIONS OF ANY ROOT
 BARRIERS REQUIRED TO PROTECT UTILITY LINES.
 BIOBARRIER IS NOT ACCEPTABLE AS ROOT BARRIER, MUST BE
 HARD PLASTIC ROOT BARRIER DEEP ROOT OR SIMILAR.
 SOME ROOT BARRIER LOCATIONS SHOWN ARE NOT APPROPRIATE,
 AS THEY SEPARATE THE ROOTS FROM REQUIRED SOIL AREAS.
 PROVIDE A ROOT BARRIER DETAIL.
  
 10. NOT SATISFIED. SHOW COMPLIANCE WITH SECTION 94-445
 L. PLANT SPECIES. A MINIMUM OF 60 PERCENT OF PLANT
 MATERIAL ADDED SHALL BE FLORIDA NATIVE OR DROUGHT
 TOLERANT SPECIES SELECTED FROM THE CITY LIST OR THE
 LIST OF SPECIES IN THE MOST RECENT EDITION OF SOUTH
 FLORIDA WATER MANAGEMENT DISTRICT WATERWISE SOUTH
 FLORIDA LANDSCAPES.
 PROVIDE THE ACTUAL PERCENTAGE OF DROUGHT TOLERANT AND
 NATIVE SPECIES ADDED BASED ON THE PROPOSED PLANT LIST.
  
 ADDITIONAL COMMENTS 8/16/19:
  
 11. PROVIDE THE 50 POINTS REQUIRED FROM THE FLORIDA
 FRIENDLY DESIGN OPTIONS FOUND IN SECTION 94-443(G).
  
 12. PER RESOLUTION NO. 304-18 UNDER 2. CITYPLACE CENTER
 B., FOUR FICUS TREES WITHIN THE PAVED AREAS NEED TO BE
 SHOWN WITH SUSPENDED PAVEMENT SYSTEM FOR THE ROOT ZONES
 OF THE TREES. PROVIDE THE LOCATIONS AND DETAIL FOR THE
 SYSTEM.
  
 CONDITIONS OF APPROVAL
 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON
 THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE
 SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT
 SERVICES DEPARTMENT, PLANNING DIVISION.
  
  Print