| Date |
Text |
| 2019-08-21 10:57:17 | DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION, |
| | COMMENTS: |
| | |
| | 1. THIS IS THE SECOND REVIEW. THE SUBMITTED LETTER |
| | RESPONSE TO THE PREVIOUS COMMENTS IS NOTED. ALL |
| | INFORMATIONAL COMMENTS PROVIDED IN THE FIRST REVIEW |
| | STILL APPLY. |
| | |
| | 2. LOCATION OF ACCESSIBLE PARKING SPACES. SITE AND |
| | PROJECT DATA SHEET A0.01 STATES THAT EXISTING SHARED |
| | PARKING WILL BE USED, AND A TOTAL OF 379 PARKING SPACES |
| | WILL BE PROVIDED, INCLUDING 9 ACCESSIBLE PARKING |
| | SPACES. BASED ON THE NUMBER OF PARKING SPACES FOR |
| | RESIDENTIAL USE, PER FAIR HOUSING ACT, 7 ACCESSIBLE |
| | PARKING SPACES MUST BE AVAILABLE FOR THE RESIDENTIAL |
| | OCCUPANCY. ACCORDING TO THE ACTIVE USE DIAGRAMS, SHEET |
| | A0.06, ACCESS TO THE RESIDENTIAL OCCUPANCY WILL BE VIA |
| | THE HIBISCUS ST DOORS TO THE 1ST FLOOR LOBBY, OR VIA |
| | THE LEVEL 2 BRIDGE FROM THE PARKING GARAGE. THEREFORE, |
| | THE 7 ACCESSIBLE SPACES REQUIRED BY THE FAIR HOUSING |
| | ACT SHOULD BE THE 7 CLOSEST PARKING SPACES TO THE |
| | HIBISCUS ST DOORS TO THE 1ST FLOOR LOBBY, AND THE LEVEL |
| | 2 BRIDGE. GROUND LEVEL FLOOR PLAN, SHEET A1.01, AND 2ND |
| | LEVEL FLOOR PLAN, SHEET A1.02, SHOW 5 ACCESSIBLE |
| | PARKING SPACES AS THE CLOSEST TO THOSE ENTRANCES. THE |
| | REMAININING ACCESSIBLE PARKING SPACES SHOWN ON 3RD |
| | LEVEL THROUGH PENTHOUSE LEVEL FLOOR PLAN, SHEETS A1.03 |
| | THROUGH A1.06, ARE FURTHER FROM THOSE TWO ENTRANCES |
| | THAN MANY OF THE REGULAR (NON-ACCESSIBLE) PARKING |
| | SPACES SHOWN ON GROUND LEVEL FLOOR PLAN, SHEET A1.01, |
| | AND 2ND LEVEL FLOOR PLAN, SHEET A1.02. THAT MEANS THAT |
| | SOME PEOPLE NEEDING ACCESSIBLE PARKING SPACES WILL BE |
| | TRAVELING FURTHER TO ACCESS THE BUILDING THAN SOME |
| | PEOPLE WHO DO NOT NEED ACCESSIBLE PARKING SPACES. |
| | CONSIDERING THE PROBABILITY THAT THE OCCUPANTS OF MORE |
| | THAN 100 OF THE CARS PARKED IN THE GARAGE FOR THE |
| | RESIDENTIAL OCCUPANCY WILL ACCESS THE BUILDING VIA THE |
| | LEVEL 2 BRIDGE, MORE THAN 2 ACCESSIBLE PARKING SPACES |
| | SHOULD BE LOCATED CLOSEST TO THE BRIDGE ENTRANCE, BUT |
| | ONLY 2 ARE CURRENTLY SHOWN. ALSO, GROUND LEVEL THROUGH |
| | PENTHOUSE LEVEL FLOOR PLAN, SHEETS A1.01 THROUGH A1.06, |
| | CURRENTLY SHOW A TOTAL OF 7 ACCESSIBLE PARKING SPACES, |
| | WHICH IS LESS THAN THE 9 REQUIRED ACCESSIBLE PARKING |
| | SPACES STATED ON SITE AND PROJECT DATA SHEET A0.01. |
| | PER SECTION 208.3 OF FLORIDA ACCESSIBILITY CODE, |
| | ACCESSIBLE PARKING SPACES ARE TO BE LOCATED ON THE |
| | SHORTEST POSSIBLE ROUTE OF TRAVEL FROM ADJACENT PARKING |
| | TO AN ACCESSIBLE ENTRANCE. THE DESIGN OF ACCESSIBLE |
| | PARKING SPACES SHALL COMPLY WITH SECTION 502 OF FLORIDA |
| | ACCESSIBILITY CODE |
| | |
| | |
| | ROBERT BROWN |
| | BUILDING OFFICIAL |
| | TEL: 561 805 6652 |
| | EMAIL: [email protected] |
| | |
| |