Plan Review Notes
Plan Review Notes For Project Z19040019
Project Number Z19040019
Review Stop Z
Sequence Number 2
Notes
Date Text
2019-08-14 11:48:12COMMENTS FROM 5/8/19 REVIEW:
 1. SATISFIED.1. PLEASE SUBMIT A FINAL SIGNED AND SEALED
 COPY OF THE SURVEY.- TWO DIFFERENT SURVEYS WERE
 SUBMITTED FOR THE PROJECT. PLEASE UPDATE SURVEY TO
 INDICATE CURRENT PROPERTY OWNERS. SURVEY SHOWS PARCEL 1
 AND 2 IS OWNED BY RUSSO DS&. AND PARCEL 4 AND 5 IS
 SHOWN AS OWNED BY GARDENIA LLC.
 2. SATISFIED 2. FOR ALL OWNERS OTHER THAN BRIGHT BLUE
 LLC PLEASE PROVIDE OWNER?S CONSENT FORM.
 3. SATISFIED 3. PLEASE INDICATE THE WIDTH OF THE
 EXISTING SIDEWALKS IN THE SURVEY.
 4. SATISFIED 4. SITE AREA REFLECTED ON MSA SURVEY
 (48,614SF) IS DIFFERENT THAN INDICATED IN SHEET A-0.7.
 PLEASE CLARIFY WHAT IS THE CORRECT AREA AND ADJUST
 DRAWINGS ACCORDINGLY. WALLACE SURVEY DOES NOT CONTAIN
 TOTAL LAND AREA INFORMATION.
 5. UNDERSTOOD, VARIANCE TO BE REQUESTED 5. PARKING USES
 ALONG GARDENIA AVENUE, ABOVE THE 3RD STORY SHALL BE
 SET-BACK A MINIMUM OF 27? FROM THE BACK OF CURB.
 6. SATISFIED 6. THE PROPOSED BUILDING MASSING SHALL BE
 RECONSIDERED. THE 24 STORY BUILDING RELATIONSHIP WITH
 THE SMALL DOUBLE HEIGHT RESIDENTIAL LOBBY AT THE CORNER
 OF DIXIE AND GARDENIA IS NOT APPROPRIATE.
 7. SATISFIED 7. THE BUILDING AREA ABOVE THE RESIDENTIAL
 LOBBY IS NOT IN COMPLIANCE WITH THE MAXIMUM 35 FEET
 SETBACK FOR FLOOR 3RD TO 7TH.
 8. NOT SATISFIED. PLAZA/PUBLIC OPEN SPACE CANNOT BE
 COUNTED AS ACTIVE USE UNLESS IT IS ADJACENT TO AN
 ACTIVE USE ON THE FRONTAGE BEING COUNTED. PROPOSED
 PROJECT HAS THE GARAGE ON THE CONTED FRONTAGE 8. ACTIVE
 USES ALONG DIXIE HWAY ARE REQUIRED ALONG 65% OF GROUND
 FLOOR FRONTAGE. BUILDABLE LOT FRONTAGE = 130.8,
 REQUIRED ACTIVE USE=85.02SF.
 9. SATISFIED 9. PROJECT DOES NOT COMPLY WITH ACTIVE USE
 REQUIREMENTS ALONG DIXIE HWAY ABOVE THE SECOND STORY
 (RESIDENTIAL LOBBY COUNTED AS TWO STORIES). 60% ACTIVE
 USES REQUIRED ALONG DIXIE HWAY FRONTAGE.
 10. NOT SATISFIED - STAFF DOES NOT BELIEVE THE PROPOSED
 SCREEN SATISFIES THE REQUIREMENTS IN SEC 94-109
 REGARDING ARQUITECTURAL TREATMENT FOR NON-ACTIVE USES.
 10. PHOTOGRAPHIC POLYVINYL COATED MESH IS NOT IN
 COMPLIANCE WITH THE ARCHITECTURAL TREATMENT REQUIRED
 FOR NON-ACTIVE USES.
 11. NOT SATISFIED - INTERIOR GARAGE ELEVATIONS ARE
 REQUIRED TO PROVIDE ARCHITECTURAL TREATMENT . 11. ALL
 NON-ACTIVE USE FACADES ARE REQUIRED TO PROVIDE
 ARCHITECTURAL TREATMENTS. PLEASE REVISE ALL GARAGE
 ELEVATION TO PROVIDE ARCHITECTURAL TREATMENT.
 12. SATISFIED 12. RESIDENTIAL LOBBY DOOR ON DIXIE HWAY
 SHALL BE RECESSED TO AVOID ENCROACHMENT INTO PEDESTRIAN
 PATH.
 13. PARTIALLY SATISFIED- PLEASE EXPLAIN MORE DETAILS ON
 THE WALL. STUCCO WALL WITH PAINT? IS THE DESIGN IN THE
 DRAWIGNS THE PROPOSED DESIGN OR A PLACE HOLDER? IT SAYS
 ARTIST MURAL BUT IS THE DESIGNED ALREADY THE ONE
 PROPOSED BY THE ARTIST?L. 13. GARAGE AND STAIRS
 ELEVATION AT THE NW CORNER DOES NOT COMPLY WITH
 ARCHITECTURAL TREATMENT REQUIREMENTS.
 14. PARTIALLY SATISFIED- CONFIRMATION BY SANITATION
 NEEDED14. PLEASE PROVIDE AUTOTURN TO CONFIRM TRUCKS CAN
 ACCESS THE PROPOSED LOADING AREA.
 15. NOT SATISFIED. LETTER FROM TRASH CONSULTANT NOT
 INCLUDED. PLEASE PROVIDE AUTOTURN FOR GARBAGE TRUCK.
 15. PLEASE DISCUSS WITH PUBLIC WORKS THE GARBAGE PICK
 UP OPERATION.
 16. PARTIALLY SATISFIED. FURTHER DISCUSSION NECESSARY
 TO DETERMINE FINAL ALLEY SECTION.16. PLEASE EXPLAIN THE
 OPERATION OF THE EXISTING ALLEY.
 17. SATISFIED. PLEASE PROVIDE DIMENSIONS ON ALL PARKING
 SPACES. 17. PARKING STALLS SHALL BE INCREASED BY ONE
 FOOT WHEN ADJACENT TO A WALL OR OTHER BUILDING
 OBSTRUCTION (SEC 94-111(C)).
 18. SATISFIED. 18. SETBACK DIAGRAM PROVIDED IN SHEET
 A-0.11 SHALL INCLUDE INFORMATION MEASURED FROM THE BACK
 OF CURB. THE PROPERTY LINE SHALL BE INDICATED.
 19. NOT SATISFIED. PLEASE LOOK AT TRANSPARENCY
 DEFINITION IN SEC 94-109.TRANSPARENCY IS ASSOCIATED
 WITH ACTIVE USES. 19. PLEASE PROVIDE GRAPHIC
 INFORMATION TO CONFIRM COMPLIANCE WITH TRANSPARENCY
 REQUIREMENTS AT THE GROUND LEVEL.
 20. SATISFIED. 20. SITE PLAN SHALL INCLUDE INFORMATION
 INDICATING THE LOCATIONS OF THE EXISTING BUILDINGS ON
 THE NORTH SIDE OF THE ALLEY.
 21. PARTIALLY SATISFIED. FOR DAC APPROVAL MORE DETAILS
 ON THE FIRST TWO FLOOR FINISHES ARE NEEDED. PLEASE
 PROVIDE DETAILS ON WOOD LOUVERS PROPOSED FOR GARAGE AND
 LOBBY AREA. PLEASE CONFIRM THE TINTED WINDOW PROPOSED
 IN THE GROUND FLOOR ALLOWES VISIBILITY FROM THE
 OUTSIDE. 21. PLEASE PROVIDE COLORED ELEVATIONS WITH
 CALL OUT MATERIALS AND IMAGES WITH MATERIALS
 REFERENCES.
 22. NOT SATISFIED. PLEASE PROVIDE THE DEPTH OF THE
 PLANAR BREAKS INDICATED. PLEASE IDENTIFY THE BUILDING
 FRONTAGE AND AD THE CUMULATIVE PERCENTAGETHAT COMPLIES
 WITH THE REQUIREMENT. 22. PLEASE PROVIDE INFORMATION TO
 CONFIRM COMPLIANCE WITH PLANAR BREAK REQUIREMENTS.
 23. NOT SATISFIED . PLEASE CLARIFY WHAT IS THE
 "MAINT/ENG" ROOM ON LEVEL 2. PLEASE INCLUDE A LINE IN
 SHEET A-1.0 LISTING THE AMOUNT OF TDRS ALLOWED
 (154,539SF), AND HOW MANY ARE NEEDED FOR THE PROJECT
 BASED ON THE LATEST FAR CALCULATION (152,779SF).
 23. PLEASE PROVIDE A SUMMARY TABLE INCLUDING, LOT AREA,
 FAR PERMITTED BY RIGHT, ADDITIONAL FAR WITH INCENTIVES,
 TOTAL GROSS BUILDING AREA PROPOSED PER FLOOR AND TOTAL.
 IN THE FLOOR PLANS ASSOCIATED WITH THE GROSS BUILDING
 AREA INFORMATION, PLEASE LABEL THE SPACES TO CLEARLY
 IDENTIFY THOSE AREAS EXCLUDED FROM THE GBA NUMBERS.
 PLEASE USE THE GBA DEFINITION IN SECTION 94-109.
 24. SATISFIED. 24. PLEASE PROVIDE A BREAKDOWN OF HOTEL
 ROOMS AND RESIDENTIAL UNITS TO CONFIRM COMPLIANCE WITH
 MINIMUM UNIT SIZE, AND AVERAGE UNIT SIZE REQUIRED BY
 CODE SEC 94-109 FULL SERVICE HOTEL DEFINITION AND
 DWELLING UNIT DEFINITION.
 25.PARTIALLY SATISFIED. PUBLIC OPEN SPACE ALLOWED IN
 THIS DISTRICT IS THE GARDEN PLAZA AND IT SHALL BE
 LOCATED AT THE CORNER. PLEASE IDENTIFY THE PUBLIC OPEN
 SPACE EXTENDING TO THE CORNER OF GARDENIA AND DIXIE.
 25. PLEASE PROVIDE GRAPHICS INDICATING THE AREA
 CALCULATED TO COMPLY WITH THE PUBLIC OPEN SPACE AND THE
 PRIVATE OPEN SPACE REQUIREMENTS AND CONFIRM COMPLIANCE
 WITH EACH OF THE REQUIREMENTS FOR EACH OPEN SPACE TYPE.
 26. SATISFIED . 26. PUBLIC OPEN SPACE AT GROUND LEVEL
 DOES NOT SEEM TO COMPLY WITH MINIMUM PROPORTIONS
 REQUIRED BY THE CODE.
 27. PARTIALLY SATISFIED. CITY STANDARD LIGHT FIXTURE
 SHALL BE INSTALLED ALONG ALL STREET FRONTAGES.
 27. PLEASE PROVIDE PHOTOMETRICS TO CONFIRM COMPLIANCE
 WITH ILLUMINATION ON THE PUBLIC RIGHT OF WAY. STANDARD
 DECORATIVE STREET LIGHT FIXTURES AND POLES SHALL BE
 PROVIDED ALONG THE STREET FRONTAGES TO MEET MINIMUM 0.6
 FOOTCANDLES AT ONE FOOT ABOVE THE SIDEWALK LEVEL NEXT
 TO THE CURB. FIXTURE AND POLE SHALL MEET APPROVED CITY
 STANDARD.
 28. SATISFIED. 28. EXISTING UNDERGROUND ELECTRIC
 CONFLICTS WITH PROPOSED STREET TREES ALONG GARDENIA.
 PLEASE DETERMINE THE POSSIBILITY FOR RELOCATION.
 29. PARTIALLY SATISFIED. PLEASE INDICATE IN WHICH SHEET
 IS THE NOTE..29. SIDEWALK ELEVATION SHALL BE MAINTAINED
 ACROSS THE PARKING GARAGE DRIVEWAY. PLEASE INCLUDE A
 NOTE AND SECTION WITHIN THE CIVIL DRAWINGS TO ENSURE
 COMPLIANCE.
 30. SATISFIED. 30. PLEASE VERIFY RENDERINGS ACCURATELY
 REFLECT THE BUILDING DESIGN, PROPOSED MATERIALS AND
 LANDSCAPE. RENDERINGS WILL BE PART OF THE APPROVAL SET.
 31. PARTIALLY SATISFIED. PLEASE LOOK AT THE SIGHT LINE
 REGULATIONS. 31. QUADRILLE BLVD IS AN FDOT RIGHT OF
 WAY. PLEASE CONFIRM PROPOSED LANDSCAPE COMPLIES WITH
 FDOT STANDARDS.
 32. SATISFIED. 32. PLEASE INDICATE THE LOCATION OF
 SECURED BIKE PARKING FOR RESIDENTIAL TENANTS(1/15
 REQUIRED PARKIGN SPACES), AND THE LOCATION OF REQUIRED
 PULBIC BIKE PARKIGN ALONG THE STREET FRONTAGES 1/100
 FEET OF STREET FRONTAGE).
  
 ADDITIONAL COMMENTS FROM 7/11/19 SUBMITTAL
 33. PLEASE INDICATE THE TREATMENT OF THE GARAGE ROOF.
 PARKING ON EXPOSED ROOF SURFACES IS DISCOURAGED. PLEASE
 CONFIRM COMPLIANCE WITH SEC 94-111(Q)(4)
 34. PLEASE CONFIRM THE PARKING GARAGE ENTRANCE IS IN
 COMPLIANCE WITH SEC 94-111(Q)(1).
 35.PLEASE REDUCE GARAGE ENTRANCE TO 20 FEET IN WITH AT
 SIDEWALK CROSSING.
 36. PLEASE CONFIRM RETAIL SPACE ALONG DIXIE HWAY IS
 INCLUDED IN THE PARKING CALCULATION.
 37. PLEASE INCLUDE THE DIMENSION OF ALL ELEMENTS ABOVE
 FLOOR 21 TO CONFIRM COMPLIANCE WITH TABLE IV-5.
 38. PLEASE EXPAND PLANTING AREA ON QUADRILLE BLVD TO BE
 A CONTINUOUS PLANTING, EXCEPT FOR PEDESTRIAN CROSSINGS.
  
 PRELIMINARY COMMENTS ON REVISED E-MAILED FLOOR PLANS
 39. IF THE DROP-OFF IS MOVED TO THE GROUND FLOOR, THE
 DROP-OFF ACTIVITY CAN POSITIVELY IMPACT GARDENIA IF THE
 MECHANICAL ROOMS ARE MOVED TO THE EAST SIDE OF THE
 PARKING ENTRANCE AND A COVER GARDEN/SEATING AREA IS
 CREATED ADJACENT TO THE DROP-OFF.
 40. PLEASE ADJUST ALL PARKING AND FAR CALCULATIONS
 ACCORDINGLY.
 41. THERE IS A POSIBILITY TO ACCOMMODATE SOME ON-STREET
 PARKING ON GARDENIA. STUDY THE SECTION TO ALLOW TWO 9
 FOOT TRAVEL LANES, 7 FOOT PARKING AND CURB AND GUTTER.
 PROJECT STILL NEEDS TO COMPLY WITH MINIMUM SETBACK.
 42. PLEASE ADJUST ALL ADA RAMPS AT ALLL CORNERS.
  
 PLEASE RE-SUBMIT DRAWINGS ADDRESSING THE COMMENTS FROM
 ALL THE DISCIPLINES, AND INCLUDE A RESPONSE LETTER WITH
 ANSWERS TO EACH COMMENT.
 PROJECT WOULD BE REQUIRED TO OBTAIN DAC APPROVAL FOR
 SPECIAL REVIEW, AND THE TRANSFER OF DEVELOPMENT RIGHTS.
 FOR ADDTIONAL INFORMATION PLEASE CONTACT ANA MARIA
 APONTE AT 561-822-1439.