| 2019-06-28 10:25:27 | GENERAL COMMENTS: |
| | |
| | 1.) A REVISED TRAFFIC PERFORMANCE STANDARDS (TPS) |
| | REVIEW LETTER FROM THE PALM BEACH COUNTY TRAFFIC |
| | DIVISION, REFLECTING CORRECT INFORMATION (I.E. 11 TH |
| | UNITS (NOT 12 UNITS) AND OWNERSHIP OF THE LAND) IS |
| | REQUIRED. [5/3/2019 REPEAT COMMENT] |
| | |
| | 2.) THE APPLICATION FOR THE VARIANCE REQUEST TO THE 20 |
| | FT. FRONT SETBACK REQUIREMENT IS CURRENTLY PENDING WITH |
| | STAFF AND APPROVAL FROM THE ZONING BOARD OF APPEALS |
| | (ZBA). PLEASE NOTE THAT SITE PLAN APPROVAL WILL BE |
| | CONTINGENT ON THE APPROVAL OF THE VARIANCE REQUEST. |
| | (REFERENCE: ZBA CASE NO. 3373) |
| | |
| | 3.) APPROVAL OF THE SITE PLAN IS CONTINGENT UPON THE |
| | APPROVAL OF THE PLAT DOCUMENT (REFERENCE: PB CASE NO. |
| | 1823) |
| | |
| | 4.) A RESOLUTION IS NEEDED FOR THE PLACEMENT OF THE |
| | POWER POLES/LIGHT FIXTURES IN THE ALLEY ROW. THE |
| | APPLICANT HAS STATED IN THE RESPONSES TO PPRC'S |
| | COMMENTS THAT THE "APPLICANT IS WORKING WITH FPL AT |
| | THIS TIME TO DETERMINE THE EXTENT OF THE EXISTING POWER |
| | POLES CAN BE RELOCATED." PLEASE CONTACT STAFF TO |
| | DISCUSS STATUS AND TO DETERMINE IF THE ZBA APPLICATION |
| | CAN MOVE FORWARD WHILE THIS ISSUE GETS ADDRESSED. |
| | |
| | 5.) ANY CHANGES TO THE PLANS (I.E. LANDSCAPE PLAN, SITE |
| | PLAN, ARCHITECTURAL PLANS, ETC.) SHALL BE CONSISTENT |
| | WITH ALL OTHER PLANS. |
| | |
| | |
| | SITE PLAN COMMENTS: |
| | |
| | 1.) NOT ALL STRUCTURAL INTRUSIONS HAVE BEEN DIMENSIONED |
| | IN THE PLANS (I.E. EYE BROW DETAIL ABOVE THE WINDOWS, |
| | OVERHANG ABOVE BALCONY SPACE, ETC.). PLEASE SHOW |
| | DIMENSIONS IN THE PLANS TO DEMONSTRATE THAT THE |
| | INTRUSIONS DO NOT EXTEND FARTHER THAN 3 FT. INTO A |
| | REQUIRED SETBACK. [5/3/19 REPEAT COMMENT] |
| | |
| | 2.) LANDSCAPE ISLANDS AND BRICK PAVERS AT THE REAR OF |
| | THE PROPERTY SHALL BE LOCATED COMPLETELY WITHIN THE |
| | BOUNDARIES OF THE SUBJECT PROPERTY AND SHALL NOT |
| | ENCROACH INTO THE ALLEY RIGHT-OF-WAY. [5/3/2019 REPEAT |
| | COMMENT] |
| | |
| | 3.) THERE IS A 6 FT. HIGH PVC FENCE LOCATED ALONG THE |
| | NORTH PROPERTY LINE OF LOT/UNIT 11. THE FENCE CANNOT |
| | EXCEED 4 FT. IN HEIGHT WITHIN THE FIRST 20 FT. OF |
| | LAMBERT AVENUE. PLEASE CORRECT/CLARIFY IN THE PLAN. |
| | [ZLDR S.94-302(B)(1)] |
| | |
| | 4.) IS THE FENCE LOCATED ALONG THE SOUTH PROPERTY LINE |
| | OF LOT/UNIT 1 4 FT. HIGH OR DOES IT TRANSITIONS TO A |
| | DIFFERENT HEIGHT? PLEASE CLARIFY IN THE PLAN. [ZLDR |
| | S.94-302(B)(1)] |
| | |
| | 5.) THE CBU MAIL BOX SHALL BE SETBACK AT LEAST 15 FT |
| | FROM THE CENTERLINE OF THE ALLEY TO A GARAGE DOOR |
| | FACING THE ALLEY, WHICHEVER IS GREATER. [ZLDR |
| | S.94-304(B)(2)] |
| | |
| | 6.) EXTENDED DRIVEWAY FOR LOT/UNIT 11 SHALL BE SET BACK |
| | AT LEAST 3 FT. FROM THE REAR PROPERTY LINE. [ZLDR |
| | S.94-482(D)(1)] |
| | |
| | 7.) THE SITE LOCATION MAP DOES NOT ACCURATELY REFLECT |
| | THE LOCATION OF THE SUBJECT SITE. PLEASE CORRECT. |
| | |
| | 8.) PLEASE ADDRESS THE FOLLOWING IN THE SETBACK |
| | INFORMATION TABLE: PROVIDED FRONT YARD: 12.5 FT. MIN. |
| | (NOT 20.10); WHERE DID THE CORNER YARD REQUIREMENT |
| | INFORMATION COME FROM? THE INFORMATION SHOULD BE |
| | REMOVED FROM THE TABLE IF NOT APPLICABLE. |
| | |
| | 9.) PLEASE CLARIFY THE PORCH SETBACK ENCROACHMENT |
| | INFORMATION IN THE SETBACK ENCROACHMENTS TABLE, AS IT |
| | IS NOT CLEAR TO STAFF. |
| | |
| | 10.) IN THE ZONING AND LAND USE INFORMATION TABLE: |
| | ELIMINATE THE REFERENCE TO 15.43 DU/AC; PLEASE CHECK |
| | THE CALCULATIONS FOR TOTAL GROSS BUILDING SF AND FAR. |
| | CALCULATIONS DO NOT SEEM TO ADD UP WITH THE |
| | CALCULATIONS PROVIDED IN THE ARCHITECTURAL DRAWINGS. |
| | |
| | |
| | LANDSCAPE PLAN: |
| | |
| | 1.) PROVIDE ORIGINAL SIGNED AND SEALED PLANS. COPIES DO |
| | NOT SUFFICE. |
| | |
| | |
| | INSTRUCTIONS FOR RESUBMITTAL: |
| | |
| | * PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN |
| | WRITTEN FORMAT. |
| | |
| | * WHEN RESUBMITTING, PLEASE PROVIDE A MINIMUM OF |
| | FIFTEEN (15) PAPER COPIES, ONE (1) REDUCED COPY IN 8.5 |
| | INCHES X 11 INCHES AND ONE (1) SET IN 11 INCHES X 17 |
| | INCHES, AND AN ELECTRONIC COPY OF ALL PLANS. |
| | |
| | * PLEASE NOTE THAT THE CHANGES ON THE RESUBMITTED PLANS |
| | MAY RESULT IN ADDITIONAL COMMENTS. |
| | |
| | * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE |
| | QUESTIONS. |
| |