Plan Review Notes
Plan Review Notes For Project Z19010004
Project Number Z19010004
Review Stop STORM
Sequence Number 2
Notes
Date Text
2019-07-29 12:01:12THE FOLLOWING COMMENTS ARE FROM THE REVIEW OF THE
 7/11/19 SUBMITTAL PACKAGE:
  
 1. LABEL VERTICAL DATUM AND PROVIDE CONVERSION TO
 NGVD1929 ON ALL SHEETS WITH ELEVATION DATA.[REPEAT
 COMMENT]
  
 2. CROSS SLOPE OF ROADWAY ADJACENT TO EMERGENCY
 ENTRANCE APPEARS TO BE UP TO 4.8% SLOPE.[REPEAT
 COMMENT]
  
 3. GENERAL CONSTRUCTION NOTES [REPEAT COMMENT]
 A. #13 CITY TO RECEIVE COPY OF FDEP ACCEPTED NOI.
 B. #21 CITY NAME MISSING.
  
 4. NO WRITTEN RESPONSES PROVIDED FOR FIRST ROUND OF
 STORMWATER COMMENTS.
  
 5. WATER AND SEWER NOTES [REPEAT COMMENT]
 A. #4 MAX. DEFLECTION MAY BE LIMITED TO 75% OF
 MANUFACTURER'S RECOMMENDATION. SEE CWPB STANDARD DETAIL
 P-12.
 B. #13 MATERIAL FOR UTILITIES TO BE MAINTAINED BY THE
 CITY OF WEST PALM BEACH TO BE PER THE CITY'S APPROVED
 MATERIALS LIST.
  
 TRACY WARD, PE
 SENIOR STORMWATER ENGINEER
 ENGINEERING SERVICES DEPARTMENT
 561-494-1120
 [email protected]
  