2018-12-10 17:34:57FROM: RAY CARANCI, LANDSCAPE PLANNER 561-822-1462
 PROJECT: 2823 BROADWAY MIXED USE Z18110018
 DECEMBER 7, 2018
 I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND
 PROVIDE THE FOLLOWING COMMENTS:
  
 1. PROVIDE A TREE DISPOSITION CHART OF THE TREES WITHIN
 THE AFFECTED AREA AND INDICATE IF THEY WILL BE
 PRESERVED IN PLACE, RELOCATED OR REMOVED. LIST THE
 BOTANICAL NAME AND PROVIDE THE CANOPY DIAMETER.
 CALCULATE THE REQUIRED MITIGATION IN SQUARE FOOTAGE.
  
 2. PROVIDE THE FLORIDA FRIENDLY LANDSCAPE DESIGN
 OPTIONS CHART SECTION 94-446 (G) AND PROVIDE THE
 REQUIRED 50 POINTS. PROVIDE BACK UP INFORMATION FOR ALL
 ITEMS CLAIMED.
  
 3. PROVIDE A PLAN SHOWING THE PARKING LANDSCAPE AREAS
 COUNTED TOWARD COMPLIANCE WITH SECTION 94-443(C)(3) AND
 (4) AND PROVIDE CALCULATIONS.
  
 4. PROVIDE CALCULATIONS FOR REQUIRED BUFFER TREES AT
 ONE FOR EVERY 30 FEET OR PORTION THEREOF FOR ALL BUFFER
 LENGTHS, AND SHOW THE NUMBER PROVIDED.
  
 5. SHOW THE LOCATIONS OF REQUIRED 10 FOOT LANDSCAPE
 BUFFERS ON THE BROADWAY, 28TH AND 27TH STREET SIDES OF
 THE PROJECT PER SECTION 94-443(D). SHOW THE BUFFER
 WIDTH PROVIDED ON THE WEST PROPERTY LINE.
  
 6. PROVIDE THE REQUIRED BUFFER TREES WITHIN THE
 PROPERTY LINE OF THE PROJECT. TREES MAY BE PLACED
 ANYWHERE WITHIN THE AREA BETWEEN THE PROPERTY LINE AND
 BUILDING. SHRUBS MAY BE PLACED BETWEEN THE CURB AND
 SIDEWALK AS PART OF ROADWAY BEAUTIFICATION TO SEPARATE
 THE PUBLIC OPEN SPACE AREAS FROM TRAFFIC.
  
 7. PROVIDE HEDGES TO SCREEN ALL PARKING AREAS FROM
 ADJACENT PROPERTIES AND STREETS.
  
 8. PROVIDE THE REQUIRED TREE OR PALM EQUIVALENT IN THE
 CENTER LANDSCAPE ISLAND IN THE ROW OF PARKING ALONG THE
 BUILDING. THE ISLAND CAN BE DESIGNED TO PLACE THE
 SIDEWALK AT ONE SIDE OF THE ISLAND RATHER THAN
 SPLITTING IT TO ACCOMMODATE A TREE.
  
 9. MULTIFAMILY REQUIREMENTS OF SECTION 94-443(D) SHALL
 APPLY FOR THE ADDITIONAL TREES REQUIRED AT ONE PER UNIT
 ADDED TO THE OVERALL SHADE TREE AND FLOWERING TREE
 REQUIREMENT. SHOW TOTAL REQUIRED AND PROVIDED.
  
 10. SHOW LINEAR FOOTAGE OF LANDSCAPED AREA ADJACENT TO
 THE BUILDING MEETS THE REQUIREMENT OF 40 PERCENT PER
 SECTION 94-443(D)(2) B.
  
 11. RECONSIDER FOXTAIL PALM SPECIES SELECTION, AS THEIR
 HIGH WATER AND FERTILIZER DEMANDS IMPOSE A MAINTENANCE
 BURDEN OVER THE LONG TERM OF THE PROJECT.
  
 12. SHOW COMPLIANCE WITH SECTION 94-445 L. PLANT
 SPECIES. A MINIMUM OF 60 PERCENT OF PLANT MATERIAL
 ADDED SHALL BE FLORIDA NATIVE OR DROUGHT TOLERANT
 SPECIES SELECTED FROM THE CITY LIST OR THE LIST OF
 SPECIES IN THE MOST RECENT EDITION OF SOUTH FLORIDA
 WATER MANAGEMENT DISTRICT WATERWISE SOUTH FLORIDA
 LANDSCAPES.
  
 13. THE LOCATIONS OF WATER AND SEWER LINES ON THE
 LANDSCAPE PLAN SHOW MANY CONFLICTS WITH TREES AND
 LANDSCAPING. RELOCATE UTILITY LOCATIONS OR EXPAND
 LANDSCAPE AREAS TO ACCOMMODATE REQUIRED LANDSCAPING.
 SHOW LOCATIONS OF FPL TRANSFORMERS ON THE LANDSCAPE
 PLAN AND RESOLVE CONFLICTS WITH LANDSCAPING.
  
 14. PROVIDE A DETAIL AND LOCATIONS OF ROOT BARRIERS TO
 SEPARATE LANDSCAPING FROM UTILITY LINES.
  
 15. PROVIDE SCREENING FOR ALL GROUND MOUNTED VALVES AND
 EQUIPMENT.
  
 16. PROVIDE THE REQUIRED HEDGE FOR THREE SIDES OF THE
 DUMPSTER ENCLOSURE AS REQUIRED.
  
 17. SHOW THE LOCATIONS OF ALL SITE LIGHTING ON THE
 LANDSCAPE PLAN AND RESOLVE ANY CONFLICTS WITH TREES.
 CONDITIONS OF APPROVAL
 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON
 THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE
 SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT
 SERVICES DEPARTMENT, PLANNING DIVISION.
  