| Date |
Text |
| 2019-02-15 10:58:58 | THE FOLLOWING COMMENTS ARE FROM THE REVIEW OF THE |
| | 1/30/2019 SUBMITTAL PACKAGE: |
| | |
| | 1. PROVIDE THE DIMENSION BETWEEN THE ADJACENT PARALLEL |
| | PARKING STRIPES ON THE STANDARD (PARKING) SPACE WITH |
| | WHEEL STOP DETAIL. [REPEAT COMMENT] |
| | |
| | 2. THE VERTICAL DATUM ON THE SURVEY IS NGVD1929. THE |
| | VERTICAL DATUM ON THE ENGINEERING PLANS IS LISTED AS |
| | NAVD1988. ALL PLANS SHOULD REFERENCE THE SAME VERTICAL |
| | DATUM AND PROVIDE A CONVERSION TO THE CITY'S VEERTICAL |
| | DATUM, NGVD1929. |
| | |
| | 3. LIST THE VERTICAL DATUM AND RELATIONSHIP TO NGVD |
| | 1929 ON EVERY ENGINEERING SHEET THAT SHOWS AN |
| | ELEVATION. THIS APPLIES TO SHEETS C-101, C-400, C-600. |
| | [REPEAT COMMENT] |
| | |
| | 4. ON SHEET C-500, PG&D NOTE #1 STATES ALL ELEVATIONS |
| | ARE REFERNCED TO NGVD 1929. THE NOTE AT THE BOOTOM LEFT |
| | OF THE SHEET STATES PLANS ARE IN NAVD1988. PLEASE |
| | CLARIFY. |
| | |
| | 5. CONSIDER ADDING ROOT BARRIERS BETWEEN THE TREES AND |
| | THE DRAINAGE PIPE(S). STAFF COULD NOT FIND WHERE THESE |
| | ROOT BARRIERS ARE CALLED OUT ON THE LANDSCAPE PLANS. |
| | |
| | 6. VERFY THE TOP OF PIPE ELEVATION LISTED FOR THE STORM |
| | PIPE IN CROSSING #1 ON SHEET C-600.. |
| | |
| | 7. UPDATE THE FLOOD ZONE INFORMATION ON THE ALTA LAND |
| | TITLE SURVEY. |
| | |
| | 8. PROPOSED 3-STORY OFFICE ADDITION MAY BE WITHIN A |
| | SPECIAL FLOOD HAZARD AREA (SFHA). THE PROPOSED FFE IS |
| | LISTED AS 15.00, WHICH IS LESS THAN TWO FEET ABOVE THE |
| | BASE FLOOD ELEVATION OF 14.0 SHOWN ON THE SURVEY. |
| | |
| | TRACY WARD, PE |
| | SENIOR STORMWATER ENGINEER |
| | ENGINEERING SERVICES DEPARTMENT |
| | 561-494-1120 |
| | [email protected] |
| |
Print |