Plan Review Notes
Plan Review Notes For Project Z18100039
Project Number Z18100039
Review Stop TRAFFIC
Sequence Number 1
Notes
Date Text
2018-11-08 14:42:29Z18100039 METROCENTRE LOT 10 (OCTOBER 9, 2018
 SUBMITTAL)
 TRAFFIC STUDY:
 1. PROVIDE TPS LETTER FROM PALM BEACH COUNTY
 2. IN FIGURE 1, THE SHADED PARCEL IS NOT THE SUBJECT
 PARCEL OF THIS AMENDMENT. PLEASE VERIFY AND REVISE.
 3. PROVIDE A SUMMARY TABLE SHOWING THE VESTED LAND USES
 AND INTENSITY OF THE CPD, AND PROPOSED LAND USES AND
 INTENSITIES WITH THIS AMENDMENT.
 4. CLARIFY IF THE CONVERSION AT THE LINCOLN COLLEGE OF
 TECHNOLOGY BUILDING FROM A VOCATIONAL SCHOOL OF 658
 STUDENTS TO 65,770 SQUARE FEET OF PROFESSIONAL OFFICE
 USE WAS A PREVIOUSLY-APPROVED CPD AMENDMENT. IF SO,
 PLEASE PROVIDE APPROVAL DOCUMENTATION. WE ARE NOT AWARE
 OF THIS CONVERSION.
 5. IN TABLE 1, THE INTENSITY OF GENERAL OFFICE UNDER
 THE PROPOSED SCENARIO IS NOT CONSISTENT WITH
 DESCRIPTION OF EXISTING AND PROPOSED LAND USES ON PAGE
 3, WHICH INDICATES THE CONVERSION TO 65,770 SF OF
 PROFESSIONAL OFFICE AND ADDITION OF 23,390 SF OF OFFICE
 WITH THIS AMENDMENT. PLEASE REVISE.
 6. DECREASE THE TRIP DISTRIBUTION TO THE WEST. 20% OF
 TRIPS ARE ASSIGNED TO 45TH STREET WEST OF MILITARY
 TRAIL, BUT RESIDENTIAL DEVELOPMENTS ARE LIMITED IN THE
 WEST.
 7. FDOT WORK PROGRAM INDICATES PRELIMINARY ENGINEERING
 IS SCHEDULED FOR THE INTERCHANGE IMPROVEMENT AT
 I-95/45TH STREET IN FISCAL YEAR 2021. PLEASE REVISE THE
 DISCUSSION ON THE ROADWAY IMPROVEMENTS SECTION
 ACCORDINGLY.
 8. THE DRIVEWAY VOLUMES SHOWN IN FIGURE 4 DO NOT APPEAR
 TO BE CONSISTENT WITH TRIP GENERATION AND TRIP
 ASSIGNMENT. PLEASE VERIFY AND REVISE.
 SITE PLAN:
 9. LOCATE MOST OF THE BIKE RACKS NEAR THE OFFICE
 BUILDING SINCE THE OFFICE USES GENERATE MAJORITY OF THE
 TRIPS.
 10. DIMENSION THE PARKING AISLE WIDTH.
 11. PROVIDE EXTERNAL PEDESTRIAN PATHWAYS TO CONNECT THE
 OFFICE BUILDING TO THE SIDEWALK ON METROCENTRE
 BOULEVARD, AND INTERNAL PEDESTRIAN PATHWAYS TO CONNECT
 BETWEEN THE OFFICE BUILDING AND THE SELF-STORAGE
 BUILDING.
 12. 3 LOADING SPACES ARE REQUIRED BUT ONLY 2 ARE
 PROVIDED. PLEASE PROVIDE JUSTIFICATION IF A WAIVER IS
 REQUESTED.
 13. PROVIDE AUTOTURN TRUCK PATHS SHOWING TRUCK ACCESS
 TO THE LOADING SPACES AND GARBAGE TRUCK ACCESS TO THE
 DUMPSTER FROM THE ACCESS POINT.
  
 ERIK D. FERGUSON, P.E.
 CITY TRANSPORTATION ENGINEER
 561-494-1092
  
  Print


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved