| Date |
Text |
| 2018-11-13 12:27:42 | FROM: RAY CARANCI, LANDSCAPE PLANNER 561-822-1462 |
| | PROJECT: METROCENTRE LOT 10 Z18100039 |
| | NOVEMBER 9, 2018 |
| | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND |
| | PROVIDE THE FOLLOWING COMMENTS: |
| | |
| | 1. THE PROPOSED LOCATION OF THE NEW BUILDING AND |
| | REMOVAL OF THE 10 MATURE LIVE OAK TREES IN THE |
| | LANDSCAPE BUFFER TO BE REPLACED WITH SMALL TREES DOES |
| | NOT MEET THE INTENT OF THE LANDSCAPE CODE FOR THE CITY, |
| | AND MAY NOT MEET THE REQUIREMENTS AND INTENT OF THE |
| | LANDSCAPE DESIGN GUIDELINES WITHIN THE COVENANTS FOR |
| | THE METROCENTRE CPD. THE MATURE TREES PROVIDE BUFFERING |
| | FROM I-95, AND THE COVENANTS REQUIRE LANDSCAPE AND |
| | TREES TO BREAKUP LARGE EXPANSES OF BUILDING WALLS BEING |
| | VIEWED FROM THE OUTSIDE OF THE CPD. THE PROPOSED |
| | CHANGES WILL HAVE TO BE APPROVED BY THE POA. |
| | |
| | 2. PROVIDE THE TOTAL TREE CANOPY CREDITS PROVIDED WITH |
| | THE PROPOSED LANDSCAPE PLAN ON THE TREE DISPOSITION |
| | PLAN, AS THE QUANTITY SHOWN IS BELOW THE MITIGATION |
| | REQUIRED. |
| | |
| | 3. THE OPEN SPACE CALCULATION FOR THE REQUIRED TREES |
| | AND FLOWERING TREES IS 40% PER THE CODE, 69,643 SQ FT. |
| | CORRECT ON PLANS AND RECALCULATE REQUIRED TREES. |
| | |
| | 4. THE PLAN SHOWING THE PARKING LANDSCAPE AREAS COUNTED |
| | TOWARD COMPLIANCE WITH SECTION 94-443(C)(3) AND (4) |
| | NEEDS TO BE REVISED TO SHOW ONLY THE AREAS WITHIN THE |
| | PARKING FIELD, AND THE TOTAL SHOWN TO MEET THE TOTALS |
| | OF BOTH SECTIONS ADDED TOGETHER. 3240 + 2310. |
| | |
| | 5. SHOW THAT THE REQUIRED PARKING LOT TREES MEET THE |
| | 75% CATEGORY ONE SHADE TREE REQUIREMENT. REQUIRED TREES |
| | INCLUDE ALL TERMINAL ISLAND AND ISLANDS ADJACENT TO |
| | PARKING SPACES. |
| | |
| | 6. CORRECT THE REQUIRED BUFFER TREE CALCULATIONS TO 22 |
| | FOR THE EAST, AND 3 FOR THE WEST. |
| | |
| | 7. APPROVED PLAN SHOWS BUFFER TREE LOCATIONS AND |
| | QUANTITIES. PROVIDE A COMPARISON TO SHOW THE QUANTITY |
| | OF TREES FOR THE PROPOSED PLAN AND THE APPROVED PLAN. |
| | |
| | 8. SHOW ALL PARKING SPACE ROW COUNTS ON THE LANDSCAPE |
| | PLAN. |
| | |
| | |
| | 9. SHOW COMPLIANCE WITH THE BUILDING PERIMETER |
| | LANDSCAPE REQUIREMENT OF 30% FOR COMMERCIAL USE FOR |
| | BOTH BUILDINGS. |
| | |
| | 10. PLEASE CORRECT THE FLORIDA FRIENDLY LANDSCAPE CHART |
| | SO THAT TREES AND SHRUBS ARE NOT COUNTED TWICE FOR EACH |
| | CATEGORY OF NATIVE AND DROUGHT TOLERANT. |
| | |
| | 11. CORRECT THE REQUIRED TREE CALCULATIONS TO CURRENT |
| | CODE OF 1500 SQ FT FOR SHADE TREES, AND 6000 SQ FT FOR |
| | FLOWERING TREE. |
| | |
| | |
| | 12. SHOW THE LOCATIONS OF WATER AND SEWER LINES ON THE |
| | LANDSCAPE PLAN AND CORRECT CONFLICTS WITH TREES AND |
| | LANDSCAPING. RELOCATE UTILITY LOCATIONS OR EXPAND |
| | LANDSCAPE AREAS TO ACCOMMODATE REQUIRED LANDSCAPING. |
| | 13. SHOW COMPLIANCE WITH SECTION 94-445 L. PLANT |
| | SPECIES. A MINIMUM OF 60 PERCENT OF PLANT MATERIAL |
| | ADDED SHALL BE FLORIDA NATIVE OR DROUGHT TOLERANT |
| | SPECIES SELECTED FROM THE CITY LIST OR THE LIST OF |
| | SPECIES IN THE MOST RECENT EDITION OF SOUTH FLORIDA |
| | WATER MANAGEMENT DISTRICT WATERWISE SOUTH FLORIDA |
| | LANDSCAPES. |
| | |
| | 14. PLEASE PROVIDE SCREENING FOR ALL ABOVE GROUND |
| | UTILITY VALVES AND BACKFLOWS PREVENTERS. |
| | |
| | CONDITIONS OF APPROVAL |
| | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON |
| | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE |
| | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT |
| | SERVICES DEPARTMENT, PLANNING DIVISION. |
| | |
| |
Print |