| Date |
Text |
| 2018-12-20 14:38:24 | MEMO TO FILE |
| | FROM: RAY CARANCI, LANDSCAPE PLANNER 561-822-1462 |
| | PROJECT: RACETRAC Z18100028 |
| | DECEMBER 20, 2018 |
| | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND |
| | PROVIDE THE FOLLOWING COMMENTS: |
| | |
| | 1. CORRECTIONS NEED TO BE MADE TO THE TREE DISPOSITION |
| | PLAN: |
| | ? SATISFIED. PROVIDE THE CURRENT CANOPY DIAMETER FOR |
| | EACH TREE |
| | ? PARTIALLY SATISFIED. SHOW CALCULATIONS FOR CANOPY |
| | SQUARE FOOTAGE BASED ON DIAMETER, 1:1 SAME CATEGORY IF |
| | UNDER 20 FEET, ACTUAL AREA 20 FEET OR MORE. |
| | IF UNDER 20 FEET DIAMETER THE MITIGATION DUE IS EQUAL |
| | TO THE CATEGORY VALUE. OAK UNDER 20 FEET IS CATEGORY 1, |
| | MITIGATION IS 300 SQ FT. TOTAL MITIGATION DUE FOR |
| | SUBMITTED LIST IS 11,479 SQ FT. |
| | ? SATISFIED. INDICATE WHY TREES #19 AND #22 WILL BE |
| | PRESERVED, AS THEY ARE HATRACKED. |
| | ? SATISFIED. CORRECT ALL SPECIES, AS SOME ARE |
| | MISIDENTIFIED. |
| | |
| | 2. PARTIALLY SATISFIED. PROVIDE THE TOTAL TREE CANOPY |
| | CREDITS PROVIDED WITH THE PROPOSED LANDSCAPE PLAN ON |
| | THE TREE DISPOSITION PLAN, AS WELL AS THE TOTAL |
| | PROPOSED TO BE REMOVED. |
| | |
| | |
| | 3. SATISFIED. INCLUDE THE EXISTING TREES TO REMAIN ON |
| | THE PLANT LIST, AS THEY ARE TO BE COUNTED TOWARD |
| | REQUIRED TREES. |
| | |
| | 4. SATISFIED. PROVIDE AN EXPLANATION FOR THE SETBACK |
| | AND THE USE OF THE SMALL TREE SPECIES FOR THE WESTERN |
| | BUFFER, AND SMALL SPECIES ON THE SOUTHERN BUFFER. |
| | |
| | 5. PARTIALLY SATISFIED. SHOW THE PARKING LANDSCAPE |
| | AREAS COUNTED TOWARD COMPLIANCE WITH SECTION |
| | 94-443(C)(3) AND (4) FOR THE AREAS WITHIN THE PARKING |
| | FIELD, AND MATCH THE TOTAL SHOWN ON THE REQUIREMENT |
| | CHART TO MEETING THE TOTAL OF BOTH SECTIONS ADDED |
| | TOGETHER. |
| | CALCULATIONS FOR REQUIRED AREAS ARE CORRECT, BUT AREA |
| | TO BE PROVIDED IS THE TOTAL OF THE TWO- 1466 SQ FT., SO |
| | 1262 SQ FT PROVIDED DOES NOT MEET THE REQUIREMENT. ADD |
| | LANDSCAPE AREA WITHIN THE PARKING FIELD AND ADJUST THE |
| | CHARTS ON LP.1 AND LP.2 TO MATCH. |
| | |
| | 6. SATISFIED. SHOW THAT THE REQUIRED PARKING LOT TREES |
| | MEET THE 75% CATEGORY ONE SHADE TREE REQUIREMENT. |
| | REQUIRED TREES INCLUDE ALL TERMINAL ISLAND AND ISLANDS |
| | ADJACENT TO PARKING SPACES. |
| | |
| | 7. SATISFIED. CORRECT THE REQUIRED BUFFER TREE |
| | CALCULATIONS TO SHOW WHOLE NUMBERS FOR REQUIRED TREES. |
| | |
| | |
| | 8. SATISFIED. SHOW ALL PARKING SPACE ROW COUNTS ON THE |
| | LANDSCAPE PLAN AND PROVIDE THE REQUIRED TREE IN THE |
| | TERMINAL ISLAND AT THE EAST END OF THE ROW OF PARKING |
| | ON THE NORTH SIDE OF THE BUILDING. |
| | |
| | |
| | 9. SATISFIED. SHOW COMPLIANCE WITH THE BUILDING |
| | PERIMETER LANDSCAPE REQUIREMENT OF 30% FOR COMMERCIAL |
| | USE AND INCLUDE THE LINEAR FOOTAGE. |
| | |
| | 10. SATISFIED. PLEASE CORRECT THE FLORIDA FRIENDLY |
| | LANDSCAPE CHART SO THAT TREES AND SHRUBS ARE NOT |
| | COUNTED TWICE FOR EACH CATEGORY OF NATIVE AND DROUGHT |
| | TOLERANT. PROVIDE GRAPHIC FOR WATER USE ZONES AND ADD A |
| | COLUMN TO THE PLANT LIST FOR NATIVE SPECIES. |
| | |
| | 11. SATISFIED. PLEASE PROVIDE SCREENING FOR ALL FPL |
| | TRANSFORMERS AND ABOVE GROUND UTILITY VALVES AND |
| | BACKFLOWS PREVENTERS. |
| | |
| | 12. SATISFIED. IDENTIFY IF UTILITIES ARE TO BE PROVIDED |
| | BY WPB OR PBC. |
| | |
| | 13. SATISFIED. SHOW LOCATIONS OF ANY ROOT BARRIERS AND |
| | PROVIDE A DETAIL FOR INSTALLATION. |
| | |
| | ADDITIONAL COMMENT 12/20/18: |
| | |
| | 14. ALL TREES IN GOOD CONDITION MUST BE PRESERVED OR |
| | RELOCATED PER SECTION 94-448(D)(3).THIS APPLIES TO THE |
| | TWO LARGE LIVE OAKS #23 AND #24. |
| | |
| | |
| | CONDITIONS OF APPROVAL |
| | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON |
| | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE |
| | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT |
| | SERVICES DEPARTMENT, PLANNING DIVISION. |
| | |
| |