2018-11-14 10:15:22PLANS AND PLATS REVIEW COMMITTEE (PPRC) ZONING REVIEW
 ___________________________________________
  
 DATE OF REVIEW: 11.14.2018
 PROJECT NO.: Z18100017
 CASE NO.: PB 1811
 ___________________________________________
  
 PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING
 REVIEW COMMENTS:
  
 1. PLANNING DIVISION STAFF WOULD LIKE TO HAVE A
 SEPARATE MEETING/DISCUSSION REGARDING THE REQUEST FOR A
 PLANNED DEVELOPMENT AND HOW IT DOES OR DOES NOT MEET
 THE REQUIREMENTS OF SEC. 94-207, INCLUDING: THE INTENT
 OF PLANNED DEVELOPMENTS, PROVISION OF CREATIVE OR
 INNOVATIVE LAND PLANNING TECHNIQUES, PUBLIC
 IMPROVEMENTS, ETC.
  
 2. PLEASE CLARIFY THE DIFFERENCE IN BOUNDARIES THAT
 EXISTS BETWEEN THE PROPERTY APPRAISER AND THE SURVEY
 SUBMITTED. THE PROPERTY APPRAISER INDICATES THAT THERE
 IS A SIGNIFICANT AMOUNT OF FEE-SIMPLE SUBMERGED LAND;
 HOWEVER, THE SURVEY INDICATES ?NO COMMENT? REGARDING
 ITEM #3 OF THE OWNERSHIP AND ENCUMBRANCE REPORT.
  
 3. THE SURVEY AND O&E REPORT REFERENCE A BLANKET
 COMCAST EASEMENT OVER ?PARCEL 2? AND THAT IT CANNOT BE
 GRAPHICALLY SHOWN. PLEASE PROVIDE MORE INFORMATION
 REGARDING THIS EASEMENT, AND A LETTER FROM COMCAST
 SHALL BE PROVIDED INDICATING NO OBJECTION TO THE
 PROPOSED DEVELOPMENT.
  
 4. THE SITE PLAN SHALL INDICATE THE FACADES OF THE
 BUILDING WITH SETBACKS MEASURED AT THE CLOSEST POINT
 BETWEEN THE FA?ADE AND THE ADJACENT PROPERTY LINE.
 ENCROACHMENTS INTO THE SETBACKS (I.E. BALCONIES, ROOF
 OVERHANGS, ETC.) SHALL BE IDENTIFIED AND DIMENSIONED
 ACCORDINGLY. SETBACKS OF THE RESIDENTIAL BUILDING ARE
 LABELED ON THE PLAN AND IDENTIFIED IN THE DATA TABLE AS
 BEING 15 FEET, BUT PORTIONS OF THE BUILDING ARE SHOWN
 CLOSER THAN THAT.
  
 5. SETBACK DIMENSIONS SHALL BE PROVIDED FOR ALL
 BUILDINGS; NO DIMENSIONS WERE PROVIDED ON THE SITE PLAN
 FOR THE IMPROVEMENTS ON THE EAST SIDE OF SOUTH FLAGLER
 DRIVE. IF THE INFORMATION IS BEING PROVIDED ON THE
 ENLARGED KEY PLANS, THEN THE SITE PLAN SHOULD HAVE
 CALLOUTS THE REFERENCE THOSE SHEETS SO THAT THE
 REVIEWER KNOWS TO LOOK AT THE ENLARGED KEY PLAN.
  
 6. AS THE PROPERTY HAS DOUBLE FRONTAGE, THE REQUIRED
 SETBACK FROM THE WEST PROPERTY LINE SHALL BE 25 FEET;
 PLEASE ADJUST THE DATA TABLE ACCORDINGLY.
  
 7. PURSUANT TO SEC. 94-207(C)(4) OF THE CITY?S ZLDRS,
 RESIDENTIAL BUILDINGS WITHIN AN RPD SHALL BE LOCATED AT
 LEAST 20 FEET FROM THE OUTERMOST PROPERTY LINE OR ANY
 PUBLIC RIGHT-OF-WAY. ALL OTHER STRUCTURES ARE TO BE AT
 LEAST 40 FEET FROM THE OUTERMOST PROPERTY LINE OR
 RIGHT-OF-WAY.
  
 8. THE DATA TABLE ON THE SITE PLAN IS INCORRECT. THERE
 ARE NO REQUIREMENTS FOR PERCENTAGE OF OPEN SPACE,
 LANDSCAPING, BUILDING COVERAGE, IMPERVIOUS SURFACE,
 ETC. PLEASE ENSURE THAT THE DATA TABLE ACCURATELY
 REFLECTS THE REQUIREMENTS OF THE CITY?S ZONING AND LAND
 DEVELOPMENT REGULATIONS.
  
 9. ON THE NORTH AND SOUTH SIDES OF THE BUILDING THERE
 ARE AREAS LABELED AS ?BAY WINDOWS?. THESE DO NOT APPEAR
 TO MEET THE DEFINITION OF A TYPICAL BAY WINDOW AND ARE
 CONSIDERED A PART OF THE FA?ADE OF THE BUILDING. AS
 SUCH, THEY SHALL MEET THE MINIMUM SETBACK REQUIREMENTS
 OR BEING PART OF A WAIVER REQUEST.
  
 10. DIMENSIONS SHALL BE PROVIDED FOR THE ROOF OVERHANG
 OF THE POOL STRUCTURE. THE ROOF OVERHANG SHALL NOT
 ENCROACH MORE THAN THREE (3) FEET INTO THE REQUIRED
 SETBACK.
  
 11. THE HEIGHT OF THE POOL STRUCTURE SHALL BE PROVIDED.
  
 12. A TABLE SHALL BE PROVIDED ON THE SITE PLAN
 IDENTIFYING ALL OF THE WAIVERS THAT ARE BEING
 REQUESTED. IT APPEARS THAT THE PROJECT DOES NOT MEET
 THE FOLLOWING REQUIREMENTS:
 12.1. SETBACKS
 12.2. BUILDING HEIGHT
 12.3. MINIMUM LAND AREA REQUIRED FOR A RESIDENTIAL
 PLANNED DEVELOPMENT
 12.4. LANDSCAPE BUFFER DIMENSIONS
 12.5. ADDITIONAL HEIGHT PERMITTED FOR MECHANICAL
 EQUIPMENT, ARCHITECTURAL ELEMENTS, ETC. ABOVE THE ROOF
 SLAB (10% MAX).
  
 13. THE DUMPSTER ENCLOSURE SHALL BE MOVED OFF OF THE
 FRONTAGE AND INTERIOR TO THE SITE.
  
 14. THE DUMPSTER ENCLOSURE DOES NOT MEET THE MINIMUM
 DIMENSIONAL REQUIREMENTS AND DOES NOT MATCH THE DETAIL
 PROVIDED.
  
 15. SHEET CP-101 INDICATES ?PROP. PARKING COVER? OVER
 THE SURFACE PARKING, WEST OF THE BUILDING; PLEASE
 CLARIFY.
  
 16. SITE PLAN NEEDS TO DIMENSION ALL SIDEWALKS.
  
 17. SITE PLAN SHALL INDICATE THE SETBACK PROPOSED FOR
 THE FREESTANDING SIGNS. PURSUANT TO SEC. 94-407(2), THE
 SIGNS SHALL BE 20 FEET FROM ADJACENT PROPERTY AND 20
 FEET FROM THE RIGHT-OF-WAY.
  
 18. A DETAIL OF THE SIGN ON SOUTH FLAGLER DRIVE SHALL
 BE PROVIDED WITH HEIGHT, DIMENSIONS OF THE SIGN FACE,
 ETC.
  
 19. PURSUANT TO SEC. 94-407(2), FREESTANDING SIGNS
 SHALL NOT EXCEED FOUR (4) FEET IN HEIGHT.
  
 20. PLANS SHALL INDICATE THE LOCATION OF CURBING, TYPE
 OF CURB, ETC. PURSUANT TO SEC. 94-443(C)(5), LANDSCAPE
 AREAS AND PLANT MATERIAL SHALL BE PROTECTED FROM
 VEHICULAR ENCROACHMENT BY CURBS OR WHEEL STOPS.
  
 21. HANDICAP PARKING STALL STRIPING AND SIGNAGE DOES
 NOT CONFORM TO THE CITY?S STANDARD.
  
 22. IMPROVEMENTS WITHIN THE SOUTH FLAGLER DRIVE
 RIGHT-OF-WAY, INCLUDING THE PROVISION OF A PEDESTRIAN
 CROSS-WALK, SHALL BE APPROVED BY THE CITY?S ENGINEERING
 SERVICES DEPARTMENT.
  
 23. ALL FENCING SHALL BE IDENTIFIED WITH HEIGHTS
 DIMENSIONED. NO INFORMATION WAS PROVIDED REGARDING
 FENCING ON THE EAST SIDE OF SOUTH FLAGLER DRIVE.
  
 24. IT APPEARS THAT THE FENCING ALONG THE NORTH AND
 SOUTH PROPERTY LINES ARE OUTSIDE THE BOUNDARIES OF THE
 SUBJECT PROPERTY. ALL IMPROVEMENTS NEED TO BE WITHIN
 THE CONFINES OF THE PROPERTY BOUNDARIES.
  
 25. AS WASHINGTON ROAD IS ALSO CONSIDERED A FRONT
 PROPERTY LINE, FENCING WITHIN THE FRONT SETBACK (25
 FEET) SHALL NOT EXCEED FOUR (4) FEET IN HEIGHT.
  
 26. ARE THE IMPROVEMENTS EAST OF THE SEAWALL A PART OF
 THIS REQUEST? IF SO, DETAILS SHALL BE PROVIDED AND ALL
 DOCKS SHALL CONFORM TO THE REQUIREMENTS OF SEC. 94-313
 OF THE CITY?S ZLDRS.
  
 27. THE INGRESS/EGRESS ACCESS POINTS ON WASHINGTON ROAD
 AND SOUTH FLAGLER DRIVE CAN BE NARROWED DOWN TO 20 FEET
 IN WIDTH; THE DRIVE AISLE ONLY NEEDS TO BE 24 FEET IN
 WIDTH WHERE PARKING BACKS OUT INTO THE DRIVE AISLE.
  
 28. BICYCLE PARKING SHALL BE PROVIDED IN ACCORDANCE
 WITH SEC. 94-485(Q) OF THE CITY?S ZLDRS. LOCATIONS OF
 BIKE RACKS SHALL BE IDENTIFIED ON THE SITE PLAN AND
 DETAILS SHALL BE PROVIDED INDICATING THE TYPE OF BIKE
 RACK AND THE MINIMUM DIMENSIONAL REQUIREMENTS FOR
 INSTALLATION, INCLUDING SPACING, SIZE OF PAD, ETC.
  
 29. PHOTOMETRIC LEVELS SHALL BE SHOWN AT THE PROPERTY
 LINES AND SHALL NOT EXCEED 0.5 FOOTCANDLES AT SUCH
 LOCATION. ALL LIGHTING SHALL BE SHIELDED TO REDUCE
 GLARE AND REFLECT LIGHT AWAY FROM ADJACENT RESIDENTIAL
 PROPERTIES.
 ___________________________________________
  
 PLEASE NOTE THE FOLLOWING WHEN RESUBMITTING:
  
 A) WRITTEN RESPONSES TO COMMENTS MADE BY ALL
 DEPARTMENTS SHALL BE PROVIDED UPON RESUBMISSION.
  
 B) 15 SETS OF REVISED PLANS AND/OR DOCUMENTS SHALL BE
 PROVIDED, ALONG WITH ONE (1) REDUCED COPY (11IN X
 17IN), AND AN ELECTRONIC COPY OF ALL PLANS.
  
 C) PLEASE NOTE THAT RE-SUBMITTALS MAY BE SUBJECT TO
 ADDITIONAL COMMENTS.
  
 D) IF NO RESPONSE IS RECEIVED WITHIN 60 DAYS OF THE
 ISSUANCE OF THESE COMMENTS, THE APPLICATION WILL BE
 CONSIDERED WITHDRAWN AND ANY FURTHER ACTION WILL
 REQUIRE SUBMISSION OF A NEW DEVELOPMENT APPLICATION.
  
 E) PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1)
 RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY-ISSUED
 COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE
 APPLICANT WILL BE ACCESSED A RESUBMITTAL FEE. SUCH FEE
 WILL BE 20% OF THE ORIGINAL APPLICATION FEE.
  
 F) IN ORDER TO BE CONSIDERED FOR THE JANUARY 15, 2019,
 PLANNING BOARD AGENDA, ALL COMMENTS SHALL BE
 SATISFACTORILY ADDRESSED. PLEASE SUBMIT ALL REVISED
 DOCUMENTS/PLANS NO LATER THAN FRIDAY, NOVEMBER 30,
 2018.
  
 G) TO BE PLACED ON THE JANUARY 15, 2019, PLANNING BOARD
 AGENDA, SIGNS SHALL BE POSTED ON THE PROPERTY NO LATER
 THAN DECEMBER 31, 2018. SIGNAGE SHALL CONFORM AND BE
 INSTALLED WITH THE REQUIREMENTS OF THE CITY?S ZONING
 AND LAND DEVELOPMENT REGULATIONS, AS ALSO PROVIDED IN
 THE DEVELOPMENT APPLICATION. A SIGNED AND NOTARIZED
 AFFIDAVIT SHALL BE PROVIDED BY THE DEADLINE REFERENCED
 ABOVE.
 ___________________________________________
  
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
  
 JOHN P. ROACH, AICP, PRINCIPAL PLANNER
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION
 401 CLEMATIS STREET - P.O. BOX 3147
 WEST PALM BEACH, FLORIDA 33402
  
 P: 561.822.1448
 F: 561.822.1460
  
 E: [email protected]
  
 W: WPB.ORG
  