2018-11-07 09:39:35GENERAL COMMENTS:
  
 1.) A COUNTY TRAFFIC PERFORMANCE STANDARDS (TPS) REVIEW
 LETTER, INDICATING THAT THE PROPOSED PROJECT MEETS THE
 TPS OF THE COUNTY SHALL BE SUBMITTED TO STAFF AS A
 PREREQUISITE FOR MOVING FORWARD TO A PUBLIC HEARING.
 [9/18/18 REPEAT COMMENT ? STAFF IS STILL WAITING ON THE
 TPS APPROVAL LETTER FROM THE COUNTY.]
  
  
 MASTER DEVELOPMENT PLAN (SHEET MP-1) COMMENTS:
  
 1.) CORRECT THE FOLLOWING LAND USE AND ZONING: A)
 PARCEL IMMEDIATELY WEST OF THE PALMS GATEWAY CPD HAS A
 LAND USE: C AND ZONING: CPD (NOT LAND USE: CS AND
 ZONING: CS), B.) THE PARCEL LOCATED AT THE NORTHWEST
 CORNER OF BELVEDERE ROAD AND AUSTRALIAN AVENUE HAS A
 LAND USE: C AND ZONING: CPD (NOT LAND USE: CS AND
 ZONING: CPD).
  
 2.) FOR THE LAND USE AND ZONING INFORMATION AND NOTES
 TABLES FOR TRACTS #2 AND #4, PLEASE CORRECT "PROPOSED
 USE" TO "APPROVED USE" AS THE SITE PLANS FOR THESE
 TRACTS HAVE ALREADY BEEN APPROVED.
  
 3.) FOR THE LAND USE AND ZONING INFORMATION AND NOTES
 FOR TRACT #3: A) THE CORRECT FAR FOR THE OVERALL CPD IS
 0.04 (NOT 0.03), B) PLEASE INCLUDE "TOTAL BUILDING
 SIZE" INFORMATION, C) CHECK AREA CALCULATIONS. THE OPEN
 SPACE, PERVIOUS AND IMPERVIOUS SURFACE CALCULATIONS DO
 NOT ADD UP (DIFFERENCE OF 2,280 SQ. FT.). ALSO CHECK
 THE PERCENTAGES. [NOTE: INCONSISTENCIES WITH THE
 CALCULATIONS HAVE BEEN CONFIRMED WITH THE CITY'S
 LANDSCAPE PLANNER], D) ACCORDING TO THE ELEVATION
 DRAWINGS, THE MAXIMUM HEIGHT OF THE PROPOSED BUILDING
 IS 30 FT. (NOT 29 FT. AS NOTED). PLEASE ADDRESS FOR
 CONSISTENCY, E) BUILDING FOOTPRINT CALCULATION DOES NOT
 MATCH THE BUILDING FOOTPRINT CALCULATION PROVIDED IN
 THE ARCHITECTURAL PLANS. PLEASE ADDRESS FOR
 CONSISTENCY.
  
 4.) THE FAR FOR TRACT #3 FOR THE ENTIRE DEVELOPMENT IS
 0.04 (NOT 0.03). PLEASE CORRECT.
  
 5.) THE OVERALL FAR FOR THE ENTIRE DEVELOPMENT IS 0.37
 (NOT 0.36). PLEASE CORRECT.
  
  
 SITE PLAN:
  
 1.) SHOW SETBACK DISTANCE FROM THE LIGHT FIXTURE TO THE
 PROPERTY LINE. SETBACK DIMENSIONS SEEM TO BE MISSING
 FOR THE FIXTURES PROVIDED ALONG THE EAST PROPERTY LINE.
 PLEASE NOTE THAT THE FIXTURES SHALL BE PLACED AT LEAST
 5 FT. FROM THE PROPERTY LINE. [ZLDR S.94-145(2)]
  
 2.) CORRECT THE FUTURE LAND USE AND ZONING FOR THE
 PARCEL ON THE WEST SIDE OF AUSTRALIAN AVENUE. THE
 CORRECT FUTURE LAND USE IS COMMERCIAL (C) AND THE
 CORRECT ZONING IS COMMERCIAL PLANNED DEVELOPMENT (CPD).
  
 3.) PARKING CALCULATIONS INCORRECT. CALCULATION FOR
 OUTDOOR STORAGE SHOULD INCLUDE ALL DISPLAY AREAS WITHIN
 THE PROJECT. PLEASE REVISE CALCULATIONS.
  
 4.) BICYCLE PARKING CALCULATIONS SHALL BE REVISED TO
 REFLECT CORRECT CALCULATIONS.
  
 5.) BICYCLE RACK DETAIL IS INCONSISTENT WITH THE
 ILLUSTRATION IN THE SITE PLAN. PLEASE ADDRESS.
  
 6.) ALL SECURITY GATES SHALL BE LABELED IN THE SITE
 PLAN.
  
 7.) WHERE IS THE ACCESS INTO THE LIFT STATION? PLEASE
 ILLUSTRATE. IS THERE A PROPOSED FENCE AROUND THE LIFT
 STATION? IF SO, PLEASE PROVIDE MORE INFORMATION (I.E.
 HEIGHT, MATERIAL, ETC.)
  
 8.) WHY IS THERE ONLY A PARTIAL RETAINING WALL ALONG
 THE SOUTH AND EAST PROPERTY LINES? PLEASE PROVIDE AN
 EXPLANATION.
  
 9.) THE PROPOSED LOCATION OF THE FLAGPOLE MAY BE IN
 CONFLICT WITH THE LANDSCAPING FOR THE PROJECT. PLEASE
 VERIFY WITH THE CITY?S LANDSCAPE PLANNER, RAY CARANCI @
 561-822-1462.
  
 10.) INCONSISTENCIES DETECTED IN THE LOT MEASUREMENTS
 PROVIDED IN THE DEVELOPMENT REGULATIONS TABLE WHEN
 COMPARED TO THE SURVEY/SITE PLAN OF THE SUBJECT
 PROPERTY AND IN THE SETBACKS (I.E. LOT FRONTAGE IS
 AUSTRALIAN AVENUE, ETC.). PLEASE ADDRESS FOR
 CONSISTENCY.
  
 11.) PLEASE MAKE THE FOLLOWING CORRECTIONS IN THE SITE
 DATA TABULAR (SHEET SP-1): A) THE NAME OF THE CPD IS
 "PALMS GATEWAY" (NOT "BW AUSTRALIAN AND BELVEDERE"), B)
 "PROPOSED ZONING DISTRICT" SHOULD BE ELIMINATED, SINCE
 THE ZONING OF THE PROPERTY IS NOT CHANGING, C) CHECK
 THE CALCULATION FOR OPEN SPACE. THERE SEEMS TO BE A
 DISCREPANCY WITH STAFF?S CALCULATION FOR OPEN SPACE, D)
 ACCORDING TO THE ARCHITECTURAL ELEVATION, THE MAXIMUM
 HEIGHT OF THE BUILDING IS 30 FT. (NOT 29 FT. AS NOTED).
 PLEASE ADDRESS FOR CONSISTENCY, E) CALCULATIONS FOR THE
 TOTAL PROPOSED NUMBER OF PARKING SPACES SHALL ALSO BE
 PROVIDED IN THE DATA TABULAR, F) PER ZLDRS, ONE (1) 10
 FT. X 25 FT. LOADING ZONE IS REQUIRED FOR THE PROJECT.
 PLEASE CORRECT IN THE TABLE.
  
 12.) PLEASE ADDRESS THE FOLLOWING IN THE REGULATING
 PLAN (SHEET SP-2): A) PROVIDE DIMENSIONS (I.E. HEIGHT)
 FOR THE PROPOSED RETAINING WALL, B) PROVIDE DIMENSIONS
 (I.E. HEIGHT) FOR THE PROPOSED RAILING.
  
  
 MASTER SIGN PLAN:
  
 1.) THE APPLICANT SHOULD BE AWARE THAT THERE IS AN
 APPROVED FREESTANDING MASTER SIGN PROGRAM FOR THE PALMS
 GATEWAY CPD. ANY PROPOSED CHANGE SHOULD BE REFLECTED IN
 THE JUSTIFICATION STATEMENT (INCLUDE DETAILS AND
 JUSTIFICATION FOR THE PROPOSED NEW MONUMENT SIGN, ETC.)
 AND IN THE APPROVED FREESTANDING MASTER SIGN PROGRAM.
  
 2.) WHAT IS THE WIDTH OF THE PROPOSED MONUMENT SIGN.
  
 3.) PLEASE NOTE THAT THE MAXIMUM ALLOWABLE SIGN AREA
 (BOTH SIDES OF THE SIGN STRUCTURE) IS 222.46 SQ. FT.
 THE PROPOSED SIGN AREA (194 SQ. FT. PER SIGN FACE)
 SEEMS TO EXCEED THE ALLOWABLE SIGN AREA.
  
  
 ARCHITECTURAL PLANS:
  
 1.) FLOOR AREA CALCULATIONS IN THE FLOOR PLANS DO NOT
 MATCH THE CALCULATIONS PROVIDED IN THE MASTER/SITE
 PLAN. PLEASE ADDRESS FOR CONSISTENCY.
  
 2.) LABEL GENERATOR ON THE NORTH ELEVATION.
  
  
 INSTRUCTIONS FOR RESUBMITTAL:
  
 * PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN
 WRITTEN FORMAT.
  
 * WHEN RESUBMITTING, PLEASE PROVIDE A MINIMUM OF
 FIFTEEN (15) PAPER COPIES, ONE (1) REDUCED COPY IN 8 .5
 INCHES X 11 INCHES AND ONE (1) SET IN 11 INCHES X 17
 INCHES, AND AN ELECTRONIC COPY OF ALL PLANS.
  
 * PLEASE NOTE THAT CHANGES ON THE RESUBMITTED PLANS MAY
 RESULT IN ADDITIONAL COMMENTS.
  
 * PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1)
 RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY-ISSUED
 COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE
 APPLICANT WILL BE ASSESSED A RESUBMITTAL FEE. SUCH FEE
 WILL BE 20 PERCENT OF THE ORIGINAL APPLICATION FEE.
  
 * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE
 QUESTIONS.
  