| Date |
Text |
| 2018-08-06 17:43:27 | Z18070015 LAMBERT AVE MULTIFAMILY (JULY 10, 2018 |
| | SUBMITTAL) |
| | - PROVIDE A TRAFFIC STATEMENT, AND DOCUMENT THE TRIP |
| | GENERATION AND TRIP ASSIGNMENT FROM THE SITE ACCESS TO |
| | THE FIRST MAJOR THOROUGHFARE. |
| | - PROVIDE TRAFFIC CONCURRENCY LETTER FROM PALM BEACH |
| | COUNTY. |
| | - INCLUDE A SITE DATA TABLE IN THE SITE PLAN, AND |
| | ILLUSTRATE THE CODE REQUIREMENTS AND PROPOSED SITE |
| | PARAMETERS INCLUDING INFORMATION ON PARKING |
| | REQUIREMENTS. |
| | - INCLUDE WAIVER REQUESTS FOR THE FOLLOWING CODE |
| | EXCEPTIONS: 1) THE SOUTHERN DRIVEWAY DOES NOT MEET THE |
| | MINIMUM CORNER CLEARANCE REQUIREMENT PER CITY CODE |
| | SECTION 94-312. 2) ONLY ONE ACCESS POINT PER PUBLIC |
| | RIGHT-OF-WAY IS ALLOWED FOR THE PROPOSED DEVELOPMENT |
| | PER CITY CODE SECTION 94-312. |
| | - PROVIDE PEDESTRIAN CURB RAMP AT THE CORNER OF LAMBERT |
| | AVENUE AND CONNISTON ROAD. |
| | - CONSIDER PROVIDING WIDER SIDEWALK ALONG LAMBERT |
| | AVENUE AND CONNISTON ROAD. |
| | - CONSIDER PROVIDING WIDER SIDEWALK IN FRONT OF THE |
| | TOWNHOMES. |
| | - PROVIDE PATHWAY ALONG THE ALLEY FOR PEDESTRIAN ACCESS |
| | TO THE BACK ENTRANCES. |
| | - MODIFY THE PEDESTRIAN PATHWAY IN INTERIOR ISLAND OF |
| | THE ANGLE PARKING TO CONNECT TO THE SIDEWALK AT A |
| | 90-DEGREE ANGLE. INCREASE THE WIDTH OF THIS PATHWAY, |
| | AND PROVIDE CURB RAMP ON THIS SIDE AND THE OPPOSITE |
| | SIDE OF THE PARKING AISLE. |
| | - DIMENSION THE PARKING SPACE OR PROVIDE DETAILS WITH |
| | DIMENSION, INCLUDING THE PARKING ANGLE OF THE ANGLE |
| | PARKING. |
| | - THE PARKING AISLE WIDTH IS NOT SUFFICIENT FOR SOME OF |
| | THE PARKING SPACES. FOR EXAMPLE, THE PERPENDICULAR |
| | PARKING SPACES ON THE SOUTHERN END OF THE PROPERTY |
| | REQUIRE 24 FEET OF AISLE WIDTH. |
| | - THE PARKING SPACE LABELED #9 DOES NOT MEET THE |
| | MINIMUM DIMENSION REQUIRED IN CITY CODE SECTION 94-485. |
| | INCREASE THE WIDTH OF THE TERMINAL ISLAND TO AT LEAST 8 |
| | FEET BETWEEN THE PARKING SPACE LABELED #10 AND THE |
| | DRIVE AISLE PER CITY CODE SECTION 94-443. |
| | - PROVIDE BICYCLE PARKING SPACES PER CITY CODE SECTION |
| | 94-485. |
| | - THE ON-STREET HANDICAPPED PARKING SPACES DO NOT MEET |
| | ADA STANDARDS FOR NEW CONSTRUCTION. THE HANDICAPPED |
| | PARKING SPACES SHOULD BE LOCATED ON-SITE NEXT TO THE |
| | TOWNHOME ENTRANCES. |
| | - CONSIDER RELOCATING ANGLE PARKING SPACES TO THE BACK |
| | OF THE PROPERTY ALONG THE ALLEY, AND PARALLEL PARKING |
| | SPACES ALONG LAMBERT AVENUE. |
| | - DIMENSION THE ROADWAY WIDTH ON BOTH LAMBERT AVENUE |
| | AND CONNISTON ROAD. |
| | - SHOW CURB AND CURB CUT ON THE OPPOSITE SIDE OF |
| | LAMBERT AVENUE AND CONNISTON ROAD ON THE SITE PLAN. |
| | - DIMENSION THE DRIVEWAY WIDTHS. |
| | - SHOW THE VISIBILITY TRIANGLE PER CITY CODE SECTION |
| | 94-305. VERIFY THE REQUIREMENTS IN THIS SECTION ARE MET |
| | WITH RESPECT TO THE PROPOSED LANDSCAPE WITHIN THE |
| | TRIANGLE. |
| | - CONSIDER ORIENTING THE TOWNHOUSE LENGTHWISE ALONG THE |
| | PROPERTY LINE ON BOTH EAST AND WEST SIDES OF THE SITE |
| | WITH PARKING IN THE MIDDLE. |
| | - NO WATER/SEWER IS SHOWN. PROVIDE WATER MAIN ON |
| | LAMBERT AVENUE. |
| | - VERIFY THAT ALL UTILITIES INCLUDING FPL POLES ARE |
| | INCLUDED ON THE CIVIL PLAN, AND VERIFY THE UTILITY |
| | POLES ARE SHOWN ON THE ALLEY VIEW OF THE RENDERING. |
| | - CONFIRM WITH FPL THAT THE BUILDING OFFSET ALONG THE |
| | ALLEY MEETS THE CLEARANCE REQUIREMENTS OF ELECTRICAL |
| | LINES. |
| | - CONSIDER PROVIDING A LANDSCAPED CURB EXTENSION ON |
| | CONNISTON ROAD ON BOTH ENDS OF THE BLOCK ALONG THE SITE |
| | FRONTAGE. |
| | |
| | ERIK D. FERGUSON, PE |
| | CITY TRANSPORTATION ENGINEER |
| | [email protected] |
| | 561-494-1092 |
| | |
| |
Print |