Notes
Date Text
2018-08-06 17:43:27Z18070015 LAMBERT AVE MULTIFAMILY (JULY 10, 2018
 SUBMITTAL)
 - PROVIDE A TRAFFIC STATEMENT, AND DOCUMENT THE TRIP
 GENERATION AND TRIP ASSIGNMENT FROM THE SITE ACCESS TO
 THE FIRST MAJOR THOROUGHFARE.
 - PROVIDE TRAFFIC CONCURRENCY LETTER FROM PALM BEACH
 COUNTY.
 - INCLUDE A SITE DATA TABLE IN THE SITE PLAN, AND
 ILLUSTRATE THE CODE REQUIREMENTS AND PROPOSED SITE
 PARAMETERS INCLUDING INFORMATION ON PARKING
 REQUIREMENTS.
 - INCLUDE WAIVER REQUESTS FOR THE FOLLOWING CODE
 EXCEPTIONS: 1) THE SOUTHERN DRIVEWAY DOES NOT MEET THE
 MINIMUM CORNER CLEARANCE REQUIREMENT PER CITY CODE
 SECTION 94-312. 2) ONLY ONE ACCESS POINT PER PUBLIC
 RIGHT-OF-WAY IS ALLOWED FOR THE PROPOSED DEVELOPMENT
 PER CITY CODE SECTION 94-312.
 - PROVIDE PEDESTRIAN CURB RAMP AT THE CORNER OF LAMBERT
 AVENUE AND CONNISTON ROAD.
 - CONSIDER PROVIDING WIDER SIDEWALK ALONG LAMBERT
 AVENUE AND CONNISTON ROAD.
 - CONSIDER PROVIDING WIDER SIDEWALK IN FRONT OF THE
 TOWNHOMES.
 - PROVIDE PATHWAY ALONG THE ALLEY FOR PEDESTRIAN ACCESS
 TO THE BACK ENTRANCES.
 - MODIFY THE PEDESTRIAN PATHWAY IN INTERIOR ISLAND OF
 THE ANGLE PARKING TO CONNECT TO THE SIDEWALK AT A
 90-DEGREE ANGLE. INCREASE THE WIDTH OF THIS PATHWAY,
 AND PROVIDE CURB RAMP ON THIS SIDE AND THE OPPOSITE
 SIDE OF THE PARKING AISLE.
 - DIMENSION THE PARKING SPACE OR PROVIDE DETAILS WITH
 DIMENSION, INCLUDING THE PARKING ANGLE OF THE ANGLE
 PARKING.
 - THE PARKING AISLE WIDTH IS NOT SUFFICIENT FOR SOME OF
 THE PARKING SPACES. FOR EXAMPLE, THE PERPENDICULAR
 PARKING SPACES ON THE SOUTHERN END OF THE PROPERTY
 REQUIRE 24 FEET OF AISLE WIDTH.
 - THE PARKING SPACE LABELED #9 DOES NOT MEET THE
 MINIMUM DIMENSION REQUIRED IN CITY CODE SECTION 94-485.
 INCREASE THE WIDTH OF THE TERMINAL ISLAND TO AT LEAST 8
 FEET BETWEEN THE PARKING SPACE LABELED #10 AND THE
 DRIVE AISLE PER CITY CODE SECTION 94-443.
 - PROVIDE BICYCLE PARKING SPACES PER CITY CODE SECTION
 94-485.
 - THE ON-STREET HANDICAPPED PARKING SPACES DO NOT MEET
 ADA STANDARDS FOR NEW CONSTRUCTION. THE HANDICAPPED
 PARKING SPACES SHOULD BE LOCATED ON-SITE NEXT TO THE
 TOWNHOME ENTRANCES.
 - CONSIDER RELOCATING ANGLE PARKING SPACES TO THE BACK
 OF THE PROPERTY ALONG THE ALLEY, AND PARALLEL PARKING
 SPACES ALONG LAMBERT AVENUE.
 - DIMENSION THE ROADWAY WIDTH ON BOTH LAMBERT AVENUE
 AND CONNISTON ROAD.
 - SHOW CURB AND CURB CUT ON THE OPPOSITE SIDE OF
 LAMBERT AVENUE AND CONNISTON ROAD ON THE SITE PLAN.
 - DIMENSION THE DRIVEWAY WIDTHS.
 - SHOW THE VISIBILITY TRIANGLE PER CITY CODE SECTION
 94-305. VERIFY THE REQUIREMENTS IN THIS SECTION ARE MET
 WITH RESPECT TO THE PROPOSED LANDSCAPE WITHIN THE
 TRIANGLE.
 - CONSIDER ORIENTING THE TOWNHOUSE LENGTHWISE ALONG THE
 PROPERTY LINE ON BOTH EAST AND WEST SIDES OF THE SITE
 WITH PARKING IN THE MIDDLE.
 - NO WATER/SEWER IS SHOWN. PROVIDE WATER MAIN ON
 LAMBERT AVENUE.
 - VERIFY THAT ALL UTILITIES INCLUDING FPL POLES ARE
 INCLUDED ON THE CIVIL PLAN, AND VERIFY THE UTILITY
 POLES ARE SHOWN ON THE ALLEY VIEW OF THE RENDERING.
 - CONFIRM WITH FPL THAT THE BUILDING OFFSET ALONG THE
 ALLEY MEETS THE CLEARANCE REQUIREMENTS OF ELECTRICAL
 LINES.
 - CONSIDER PROVIDING A LANDSCAPED CURB EXTENSION ON
 CONNISTON ROAD ON BOTH ENDS OF THE BLOCK ALONG THE SITE
 FRONTAGE.
  
 ERIK D. FERGUSON, PE
 CITY TRANSPORTATION ENGINEER
 [email protected]
 561-494-1092
  
  Print


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved