Plan Review Notes
Plan Review Notes For Project Z18070013
Project Number Z18070013
Review Stop L
Sequence Number 1
Notes
Date Text
2018-08-07 17:27:36FROM: RAY CARANCI, LANDSCAPE PLANNER 561-822-1462
 PROJECT: CENTREPARK CPD RESIDENTIAL Z18070013
 AUGUST 7, 2018
 I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND
 PROVIDE THE FOLLOWING COMMENTS:
  
 1. THERE ARE CORRECTIONS TO BE MADE TO THE TREE
 DISPOSITION PLAN SHEET TD-1:
 ? SECTION 94-448 (D)(3) REQUIRES ALL NATIVE TREES AND
 PALMS IN GOOD CONDITION TO BE PRESERVED OR RELOCATED.
 THE 19 ROYAL PALMS CAN BE RELOCATED ON SITE, WITHIN THE
 CENTREPARK CPD, OR THE CITY HAS MANY LOCATIONS WITHIN
 PUBLIC RIGHT OF WAYS FOR RELOCATION.
 ? CORRECT THE PROVIDED MITIGATION CHART FOR REPLACEMENT
 <20?SPREAD TOTAL TO 3,800
 ? CORRECT THE REQUIRED MITIGATION TO 200 TOTAL FOR
 LIGUSTRUMS
  
 2. UPDATE THE FLORIDA FRIENDLY LANDSCAPE DESIGN OPTIONS
 CHART TO CURRENT CODE SECTION 94-446 (G) FOR ALL
 OPTIONS UNDER (3) GROUNDCOVER OR GRASS.
  
 3. PROVIDE THE PLANT LIST, LANDSCAPE REQUIREMENTS,
 OVERALL LANDSCAPE REQUIREMENTS, AND LANDSCAPE NOTES ON
 ONE SHEET ONLY. LANDSCAPE PLAN CAN THEN BE CONSOLIDATED
 ONTO TWO SHEETS.
  
 4. REVISE THE PLANT LIST TO ADD A COLUMN FOR FLORIDA
 NATIVE PLANTS AND FOR DROUGHT TOLERANCE LEVEL FOR EACH
 SPECIES FOR CLARITY.
  
 5. ON THE LANDSCAPE REQUIREMENTS CHART, CORRECT THE
 SITE LANDSCAPE CALCULATIONS TO SHOW THE SHADE TREE AND
 FLOWERING TREE CALCULATIONS AND ADD THE ONE TREE PER
 UNIT REQUIRED PER SECTION 94-443 (D)(2)A. TO ACHIEVE
 THE TOTAL REQUIRED TREE COUNT OF 285. CORRECT THE
 PROVIDED TOTAL TREES TO 68, AS ANY PALMS EXCEPT THE
 ROYALS COUNT AS 3 TO 1 FOR SUBSTITUTION FOR REQUIRED
 TREES. STAFF SUGGESTS THAT ONCE CORRECTIONS AND
 CALCULATIONS ARE FINALIZED, THE DEFICIENCY OF TREES
 REQUESTED THROUGH THE WAIVER PROCESS MAY BE ADDRESSED
 THROUGH IN LIEU MITIGATION AS PROVIDED IN SECTION
 94-448 (E)(2), OR POSSIBLE PLANTING OF TREES WITHIN THE
 CENTREPARK CPD.
  
 6. SHOW THE PERCENTAGE OF PALMS SUBSTITUTED FOR
 REQUIRED TREES NOT EXCEEDING 35 PERCENT PER SECTION
 94-442(D) FOR THE TREES PROPOSED WITH THIS PLAN.
  
 7. CORRECT THE CALCULATIONS FOR THE NORTH BUFFER TO 7.
 INCLUDE CALCULATIONS FOR THE SOUTH REQUIRED BUFFER.
  
  
 8. SHOW THE LOCATIONS OF ALL LANDSCAPE BUFFERS ON THE
 LANDSCAPE AND SITE PLAN. THE SOUTH PROPERTY LINE
 REQUIRES A 5 FOOT BUFFER.
  
  
 9. SHOW COMPLIANCE WITH SECTION 94-445 L. PLANT
 SPECIES. A MINIMUM OF 60 PERCENT OF PLANT MATERIAL
 ADDED SHALL BE FLORIDA NATIVE OR DROUGHT TOLERANT
 SPECIES SELECTED FROM THE CITY LIST OR THE LIST OF
 SPECIES IN THE MOST RECENT EDITION OF SOUTH FLORIDA
 WATER MANAGEMENT DISTRICT WATERWISE SOUTH FLORIDA
 LANDSCAPES.
  
 10. PLEASE SHOW LOCATIONS OF WATER, SEWER, FIRE LINES,
 DRAINAGE LINES AND FPL TRANSFORMERS ON THE LANDSCAPE
 PLAN AND RESOLVE CONFLICTS WITH LANDSCAPING.
  
 11. PROVIDE SCREENING FOR ALL GROUND MOUNTED VALVES AND
 EQUIPMENT.
  
 12. SHOW THE LOCATIONS OF ALL SITE LIGHTING ON THE
 LANDSCAPE PLAN AND RESOLVE ANY CONFLICTS WITH TREES.
  
 13.
  
 RESOLUTION NO. 97-17
  
 14. PER EXHIBIT F, APPROVAL FROM THE ARCHITECTURAL
 REVIEW BOARD MUST BE PROVIDED FOR THE LANDSCAPE AND
 IRRIGATION PROPOSED.
  
 15. PER EXHIBIT F, PLANT MATERIAL, A MINIMUM OF 33
 PERCENT OF ALL PLANT MATERIALS SHALL BE NATIVE TO
 SOUTHERN FLORIDA. PROVIDE VERIFICATION.
  
 16. VERIFY CONDITION #7 AND #10 ARE SATISFIED WITH THIS
 PLAN, AS IT APPEARS THE LAKE BANK IS PROPOSED TO BE
 CHANGED, REMOVING SOME BUFFER ZONE AND REQUIRED
 LITTORAL PLANTINGS.
  
 17. SHOW LOCATION OF PUMP EQUIPMENT AND SOURCE FOR THE
 IRRIGATION SYSTEM TO MEET CONDITION #11 REQUIRING USE
 OF SURFACE WATER FROM LAKES.
  
  
 18. VERIFY CONDITION #12 IS MET FOR ALL REQUIREMENTS
 FOR NATIVE VEGETATION INCLUDING AT LEAST 50 PERCENT OF
 THE TREES BEING NATIVE SPECIES ADAPTED TO SOIL
 CONDITIONS ON SITE.
  
  
 CONDITIONS OF APPROVAL
 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON
 THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE
 SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT
 SERVICES DEPARTMENT, PLANNING DIVISION.
  