| Date |
Text |
| 2018-08-22 17:00:44 | FROM: RAY CARANCI, LANDSCAPE PLANNER 561-822-1462 |
| | PROJECT: PEGGY ADAMS Z18060025 |
| | AUGUST 21, 2018 |
| | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND |
| | PROVIDE THE FOLLOWING COMMENTS: |
| | |
| | 1. THERE ARE CORRECTIONS TO BE MADE TO THE TREE |
| | DISPOSITION PLAN: |
| | ? SATISFIED. TREES AND PALMS BELOW 103111 ARE MISSING |
| | FROM THE DISPOSITION CHART. |
| | ? SATISFIED. 103304 AND 103308 ARE LISTED AS PRESERVE, |
| | BUT MARKED ON PLAN AS REMOVED. |
| | ? SATISFIED. ALL TREES TO BE REMOVED MUST LIST THE |
| | CANOPY DIAMETER TO CALCULATE THE MITIGATION REQUIRED. |
| | |
| | 2. PARTIALLY SATISFIED. UPDATE THE FLORIDA FRIENDLY |
| | LANDSCAPE DESIGN OPTIONS CHART TO CURRENT CODE SECTION |
| | 94-446 (G) AND PROVIDE 50 POINTS AS REQUIRED. |
| | CORRECT THE FOLLOWING: |
| | ? #8 MULCH IS ONLY 5 POTENTIAL POINTS. |
| | ? #3 CANNOT COUNT 51% NATIVE AND 51% DROUGHT TOLERANT. |
| | ? NOTE SHOULD READ: PLANTS MAY ONLY BE COUNTED ONCE FOR |
| | CREDIT TOWARD DROUGHT TOLERANT OR FLORIDA NATIVE |
| | PLANTS. |
| | |
| | 3. SATISFIED. PLEASE SHOW LOCATIONS OF FIRE LINES AND |
| | ON THE LANDSCAPE PLAN AND RESOLVE CONFLICTS WITH |
| | LANDSCAPING. THERE ARE SEVERAL LANDSCAPE ISLANDS THAT |
| | HAVE LINES CONFLICTING WITH REQUIRED TREES. |
| | |
| | 4. PARTIALLY SATISFIED. PLEASE PROVIDE THE REQUIRED |
| | TREES IN THE TWO TERMINAL LANDSCAPE ISLANDS IN THE ROW |
| | OF PARKING ADJACENT TO THE ENTRANCE TO THE NEW |
| | BUILDING, AND THE TWO TERMINAL ISLANDS AT THE NORTH END |
| | OF THE PARKING ROWS WEST OF THE DOME BUILDING. |
| | NON-CONFORMING PARKING ROW ON THE NORTH SIDE OF THE NEW |
| | BUILDING MAY ALSO HAVE TREES ADDED IN TERMINAL ISLANDS. |
| | ANY MODIFICATIONS TO ANY PARKING AREAS REQUIRES |
| | COMPLIANCE WITH CURRENT CODE. |
| | |
| | LANDSCAPE ISLANDS ADJACENT TO THE NEW BUILDING AND AT |
| | THE SOUTHEAST CORNER OF THE DOME BUILDING ARE SHOWN |
| | WITH SINGLE ALEXANDER PALMS THAT DO NOT MEET THE CODE |
| | REQUIREMENT. THERE IS SUFFICIENT PLANTING AREA TO |
| | INSTALL ROOT BARRIERS TO PROTECT THE LINES AND ADD THE |
| | REQUIRED TREE. |
| | |
| | 5. SATISFIED. SHOW COMPLIANCE WITH SECTION 94-445 L. |
| | PLANT SPECIES. A MINIMUM OF 60 PERCENT OF PLANT |
| | MATERIAL ADDED SHALL BE FLORIDA NATIVE OR DROUGHT |
| | TOLERANT SPECIES SELECTED FROM THE CITY LIST OR THE |
| | LIST OF SPECIES IN THE MOST RECENT EDITION OF SOUTH |
| | FLORIDA WATER MANAGEMENT DISTRICT WATERWISE SOUTH |
| | FLORIDA LANDSCAPES. |
| | |
| | 6. PARTIALLY SATISFIED. THE REMOVAL AND MITIGATION OF |
| | TREES FOR THE DRAINAGE AREA RELOCATION WAS APPROVED |
| | WITH A TREE ALTERATION PERMIT. A LANDSCAPE PERMIT WAS |
| | NOT APPLIED FOR OR ISSUED FOR THE INSTALLATION OF THE |
| | NEW TREES. A LANDSCAPE PERMIT WITH AN AS BUILT PLAN |
| | MUST BE SUBMITTED FOR THE NEW DRAINAGE AREA TO CONFIRM |
| | THAT ALL REQUIRED MITIGATION HAS BEEN COMPLETED. |
| | |
| | A LANDSCAPE PERMIT WAS SUBMITTED, REVIEWED AND APPROVED |
| | AS THE AS BUILT, BUT I WAS INFORMED IS NOT ACCURATE TO |
| | THE AS BUILT PRIOR TO IT BEING ISSUED. THE CORRECTED |
| | PLAN MUST BE SUBMITTED, REVIEWED, APPROVED AND |
| | INSPECTED TO VERIFY IT IS ACCURATE. AT THAT TIME THE |
| | PLAN CAN BE INCLUDED WITH THE SUBMITTAL PLAN SET WITH |
| | ANY CORRECTIONS MADE TO THE OVERALL SITE CALCULATIONS. |
| | |
| | 7. SATISFIED. THE PROPOSED INSTALLATION OF NEW PARKING |
| | CONFIGURATION NORTH OF THE DOME BUILDING ELIMINATES AN |
| | EXISTING LANDSCAPE AREA WITH PALMS THAT IS FUNCTIONING |
| | AS A BUFFER BETWEEN THE BUILDING AND THE ADJACENT |
| | PROPERTY. MOVING THE DRIVE AISLE CLOSER TO THE BUILDING |
| | WOULD ALLOW THE REQUIRED BUFFER TO BE CREATED ALONG THE |
| | PROPERTY LINE. |
| | |
| | 8. SATISFIED. THE LOCATIONS PROPOSED FOR THE TEMPORARY |
| | TRAILERS WOULD REQUIRE THE REMOVAL OF TWO BLACK OLIVE |
| | SHADE TREES. THE TREES PROPOSED TO BE ADDED NEAR THE |
| | TRAILERS ARE SMALL SCALE TREES. |
| | STAFF RECOMMENDS LOOKING AT TRAILER PLACEMENT OPTIONS |
| | THAT WOULD AVOID REMOVING THE TREES, AND PROPOSED TREES |
| | TO BE LARGE SPECIES. |
| | |
| | 9. SATISFIED. PLEASE PROVIDE COMPLIANCE WITH THE 30 |
| | PERCENT REQUIREMENT FOR PERIMETER LANDSCAPING FOR THE |
| | TRAILERS. |
| | |
| | 10. PARTIALLY SATISFIED. PLEASE SUPPLY A COMPREHENSIVE |
| | LANDSCAPE PLAN FOR THE SITE, WITH AN ACCOUNTING OF THE |
| | TREES ON SITE AND INCLUDE ALL CURRENTLY APPROVED PLANS |
| | SO THAT STAFF CAN EVALUATE THE COMPARISON BETWEEN THE |
| | OVERALL REQUIRED TREES AS APPROVED WITH THE CSPD AND |
| | WHAT IS PROPOSED FOR THE FINAL DESIGN. |
| | |
| | SEE COMMENT #6. |
| | |
| | ADDITIONAL COMMENTS 8/20/18: |
| | 11. TEMPORARY TRAILERS DETAIL INCLUDES TREES AND HEDGE. |
| | IF TREES AND HEDGE ARE TO STAY AFTER TRAILER REMOVAL, |
| | SHOW IT ON SHEET LP-2 AS PERMANENT. THE 4 CE2 ARE |
| | CURRENTLY COUNTED TOWARD SITE TREE CREDITS ON THE PLANT |
| | LIST. |
| | |
| | 12. SHOW THE TREES AND SHRUBS IN THE BUFFER ALONG |
| | MILITARY TRAIL ON SHEET LP-2 THAT ARE WITHIN THE LIMITS |
| | OF AFFECTED AREA. THEY CAN BE NOTED AS APPROVED AS |
| | SHOWN ON OTHER SHEETS, BUT THE BUFFER MUST BE SHOWN |
| | ACCURATELY FOR THE NEW BUILDING. |
| | |
| | 13. SHOW THE BUFFER HEDGE ALONG THE NORTH PROPERTY LINE |
| | FOR ALL AREAS NOT SUBJECT TO THE WAIVER REQUEST, AS |
| | THERE ARE PORTIONS NOT SHOWN ON THE SUBMITTED PLANS. |
| | CONDITIONS OF APPROVAL |
| | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON |
| | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE |
| | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT |
| | SERVICES DEPARTMENT, PLANNING DIVISION. |
| | |
| |