Plan Review Notes
Plan Review Notes For Project Z18060022
Project Number Z18060022
Review Stop Z
Sequence Number 2
Notes
Date Text
2018-09-26 16:14:08CASE NO. PB 1799 & 1799A
 PROJECT NAME: 1309 SOUTH FLAGLER -1ST RESUBMITTAL
 1309 SOUTH FLAGLER
  
 - CONTACT ERIC SCHNEIDER @ (561) 822-1446
  
 - PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN
 WRITTEN FORMAT.
  
 - WHEN RESUBMITTING, PLEASE PROVIDE A MINIMUM OF ELEVEN
 (11) PAPER COPIES AND AN ELECTRONIC COPY IN .PNG FORMAT
 OF ALL PLANS. PLEASE NOTE THAT CHANGES ON THE
 RESUBMITTED PLANS OR THE SUBMITTAL OF INFORMATION/PLANS
 TO ADDRESS THE COMMENTS MAY RESULT IN ADDITIONAL
 COMMENTS.
  
 - THE PPRC COMMENTS SHALL BE SUFFICIENTLY ADDRESSED AND
 SUBMITTED TO THE PLANNING DIVISION BY 5 PM ON FRIDAY,
 OCTOBER 5, 2018, TO BE ELIGIBLE TO BE SCHEDULED FOR THE
 NOVEMBER 20, 2018 PLANNING BOARD MEETING.
  
 - PLEASE NOTE THAT IF THE PLANNING DIVISION HAS NOT
 RECEIVED A RESPONSE TO THE COMMENTS WITHIN 60 DAYS FROM
 THE DATE OF THE COMMENTS (BY NOVEMBER 26, 2018), THE
 CASE SHALL BE CONSIDERED WITHDRAWN. ANY FURTHER ACTION
 SHALL REQUIRE A NEW DEVELOPMENT APPLICATION.
  
 - PLEASE NOTE THAT SINCE PREVIOUSLY-ISSUED COMMENTS
 WERE NOT BE SUFFICIENTLY ADDRESSED, THE APPLICANT IS
 ASSESSED A RESUBMITTAL FEE. SUCH FEE IS BE 20% OF THE
 ORIGINAL RPD APPLICATION FEE ($600).
  
 - PUBLIC HEARING NOTIFICATION SIGNAGE SHALL BE POSTED
 IN ACCORDANCE WITH THE REQUIREMENTS OF SECTION
 94-39(I)(5) OF THE ZONING AND LAND DEVELOPMENT
 REGULATIONS.
  
 1) REVISED COMMENT: THE BASE MEASURE POINT REQUIRES
 FURTHER DISCUSSION BASED ON THE SUBMITTED PLANS.
  
 2) REPEAT COMMENT: THE PROPOSED IMPROVEMENTS TO ACACIA
 ROAD NEED TO MEET THE ENGINEERING SERVICES DIVISION
 REQUIREMENTS PRIOR TO SCHEDULING THE CASE BEFORE THE
 PLANNING BOARD. ** THE RESPONSE THAT THIS IS TO BE
 SHOWN ON A SEPARATE RIGHT-OF-WAY PERMIT IS NOT
 ACCEPTABLE. THE ACACIA ROAD IMPROVEMENTS ARE BEING USED
 AS AN INNOVATIVE LAND PLANNING AND DEVELOPMENT
 TECHNIQUE TO CREATE MORE DESIRABLE AND ATTRACTIVE
 DEVELOPMENT IN ORDER TO RELAX THE HEIGHT/SETBACK
 REQUIREMENTS; THEREFORE, YOU NEED TO PROVIDE A DESIGN
 THAT MEETS ALL THE ENGINEERING SERVICES DIVISION
 CRITERIA PRIOR TO STAFF MAKING A RECOMMENDATION ON IF
 IT IS APPROPRIATE AS A MITIGATION MEASURE. FOR EXAMPLE,
 IF THE EXISTING UTILITIES, BELOW AND ABOVE GROUND, DO
 NOT PERMIT THE INSTALLATION OF TREES, THEN THE ACACIA
 ROAD IMPROVEMENTS PROVIDE A MINIMAL AMOUNT TO THE
 ATTRACTIVENESS OF THE DEVELOPMENT.
  
 A. PROVIDE A CROSS SECTION AND MORE DETAILS OF THE
 PROPOSED IMPROVEMENTS. THE CURRENT ELEVATION OF ACACIA
 ROAD IS SHOWN ON THE SURVEY SLOPING FROM APPROXIMATELY
 SIX (6) FEET TO 10 FEET ALONG THE NORTHERN PROPERTY
 BOUNDARY OF THE 1309 S. FLAGLER DEVELOPMENT SITE. THE
 SAME LOCATION IS SHOWN HAVING AN ALMOST CONSISTENT 10
 FOOT ELEVATION. HOW IS THIS FOUR (4) FOOT GRADE CHANGE
 BEING INTEGRATED WITH THE PROPERTIES TO THE NORTH AND
 SOUTH OF THE SITE AS WELL AS TOWARD FLAGLER DRIVE. **
 NOT PROVIDED.
 B. PROVIDE DETAILS OF THE PEDESTRIAN PERMEABLE PAVING
 AND THE BENCHES THAT ARE PROPOSED. ** NOT PROVIDED -THE
 ENGINEERING SERVICES DIVISION MUST AGREE WITH THE
 PROPOSED PAVERS.
 C. PROVIDE DETAILS ON ADA ACCESSIBILITY. ** THIS NEEDS
 TO BE PROVIDED ON THE PLANS. NOT ONLY SLOPE, BUT ADA
 COMPLIANT MATERIALS.
 D. THE SKY BIKE CONTRACT IS WITH THE DDA AND DOES NOT
 EXTEND OUTSIDE OF DOWNTOWN. ALL OF THE BICYCLE SHARE
 FACILITIES NEED TO BE LOCATED ON THE 1309 S. FLAGLER
 PROPERTY. PLEASE NOTE THAT NO ADVERTISING FACILITIES
 WILL BE PERMITTED. SINCE THE BICYCLE SHARE IS BEING
 USED AS AN INNOVATIVE LAND PLANNING AND DEVELOPMENT
 TECHNIQUE TO CREATE MORE DESIRABLE AND ATTRACTIVE
 DEVELOPMENT IN ORDER TO RELAX THE HEIGHT/SETBACK
 REQUIREMENTS, THEN YOU WILL NEED TO PROVIDE
 DOCUMENTATION FROM SKY BIKE THAT THIS LOCATION IS
 ACCEPTABLE TO THEM (WITHOUT ADVERTISING), TO INCLUDE A
 PRELIMINARY AGREEMENT TO LOCATE THEIR FACILITIES OFF
 CURRIE CRESCENT PRIOR TO SCHEDULING THE CASE BEFORE THE
 PLANNING BOARD. ** NO WRITTEN RESPONSE PROVIDED.
 E. THE 1309 SOUTH FLAGLER HOMEOWNER' ASSOCIATION WILL
 NEED TO MAINTAIN ALL IMPROVEMENTS WITHIN THE ACACIA
 ROAD ROW AS WELL AS PROVIDE THE ELECTRICITY FOR THE
 LIGHTING. ** CONDITION
  
 3) REVISED COMMENT: THE SURVEY SHOWS A SIX (6) FOOT
 WIDE UTILITY EASEMENT ALONG THE SOUTH PROPERTY LINE.
 THE LANDSCAPE BUFFER IS NOT PERMITTED TO BE PLANTED
 WITHIN THIS EASEMENT. ** THE COMMENT RESPONSE STATES
 THAT THE EASEMENT WILL BE VACATED AND THE UTILITIES
 RELOCATED. PLEASE PROVIDE A PRELIMINARY APPROVAL FROM
 FPL, THE EASEMENT HOLDER, THAT THEY DO NOT OBJECT TO
 THE PROPOSED VACATION AND RELOCATION.
  
 4) REPEAT COMMENT: IN ORDER TO MAINTAIN THE OPEN
 CHARACTER OF SOUTH FLAGLER DRIVE, THE RECENT
 REDEVELOPMENT PROJECTS (LA CLARE AND BRISTOL) HAVE BEEN
 REQUIRED TO PROVIDE OPEN SPACE THAT IS PUBLICLY
 ACCESSIBLE AND THAT DOES NOT HAVE BARRIERS SUCH AS
 WALLS OR FENCES ALONG THEIR FLAGLER DRIVE FRONTAGES. **
 STAFF DOES NOT SUPPORT THE REVISED PLAN AS IT DOES NOT
 PROVIDE FOR THE EXPECTATION OF OPEN SPACE ALONG FLAGLER
 DRIVE.
  
 5) REPEAT COMMENT: STAFF DOES NOT SUPPORT THE 40 FOOT
 DRIVEWAY OPENING ALONG FLAGLER DRIVE. THIS CREATES AN
 UNNECESSARILY WIDE CROSSING POINT FOR PEDESTRIANS,
 WHICH DOES NOT PROMOTE SAFETY. ADDITIONALLY, USING MORE
 THAN A THIRD OF THE PROPERTY FRONTAGE FOR VEHICULAR
 ACCESS DOES NOT PROMOTE THE CITY'S AESTHETIC VISION FOR
 FLAGLER DRIVE.
  
 6) PARKING
  
 A. CONSTRUCTION SERVICES DEPARTMENT VERIFICATION THAT
 THE PROVISION OF PARKING SPACES AT THIS LOCATION DOES
 NOT REQUIRE THE PROVISION OF ADA SPACES AS WELL. **
 CONDITION - SIGNED "VALET ONLY" SO NO ADA REQUIRED.
 B. REPEAT COMMENT: INCLUDE PARKING SPACE WIDTH
 DIMENSIONS ON THE SITE PLAN FOR GARAGE PARKING. ** NOT
 PROVIDED.
 C. REVISED COMMENT: THE PARKING TABLE NEEDS TO BE
 UPDATED TO REMOVE THE TWO TOWN CAR SPACES FROM THE
 "REQUIRED" COLUMN.
 D. REPEAT COMMENT: THE PARKING TABLE NEEDS TO HAVE LINE
 ITEMS FOR THE NUMBER OF ADA SPACES REQUIRED AND
 PROVIDED.
 E. NEW COMMENT: WHAT ARE THE "3 CAR GARAGE SPACES"?
 F. NEW COMMENT: PROVIDE THE DEPTH OF COMPACT SPACE NO.
 9 ON BASEMENT 2. IT APPEARS SHORT.
 G. NEW COMMENT: HOW WILL THE RESIDENT PARKING SPACES BE
 ASSIGNED? STAFF HAS CONCERNS ABOUT THE VEHICLE CHARGING
 STATION ASSIGNMENT. IF RESIDENTS ARE BUYING SPECIFIC
 INDIVIDUAL SPACES, IT MAY BE BETTER TO PRE-WIRE THE
 ENTIRE GARAGE AND THEN THE RESIDENTS CAN PAY FOR A
 CHARGING INSTALL IF THEY HAVE AN ELECTRIC VEHICLE.
  
 7) REVISED COMMENT: THE B1 VENTILATION MAY NOT BE IN
 THE REQUIRED TURN AROUND SPACE AS THIS WILL MAKE THE
 SPACE NONE FUNCTIONING TO USE FOR TURN AROUND.
  
 8) BICYCLE FACILITIES.
  
 A. REPEAT COMMENT: PROVIDE DETAILS OF THE BICYCLE
 STORAGE ROOM SO THAT STAFF CAN EVALUATE IF THE TYPE OF
 RACKS THAT ARE PROVIDED ARE APPROPRIATE FOR THE NUMBER
 OF SPACES. ** INADEQUATE DETAIL PROVIDED.
 B. REVISED COMMENT - PROVIDE A CITY COMPLIANT BICYCLE
 RACK DETAIL. ** THE SITE PLAN DOES NOT VERIFY THAT THE
 PROVIDED EMPLOYEE BICYCLE PARKING COMPLIES WITH CITY
 CODE. PROVIDE A DETAIL THAT SPECIFICALLY SHOWS HOW THE
 BICYCLE RACK WITH THE TWO BICYCLES WILL FUNCTION WHERE
 IT IS SHOWN AGAINST THE WALL. INCLUDE DIMENSIONS TO
 SHOW THAT THE EGRESS PATH IS NOT BLOCKED.
  
 9) WHAT ARE THE AREAS LABELED SUITE 1 AND 2? CONDITION
 - NO KITCHEN FACILITIES.
  
 10) SHEET A3-02 SHOWS THE GENERATOR BELOW THE HEIGHT OF
 THE SCREENING. PLEASE BE AWARE THAT THE GENERATOR NEEDS
 TO BE SCREENED FOR ITS FULL HEIGHT, SO ENSURE THAT THE
 GENERATOR THAT IS USED IS NOT TOO LARGE TO AVOID ISSUES
 AT THE TIME OF PERMITTING. CONDITION - GENERATOR
 COMPLETE HEIGHT SCREENED.
  
 11) REPEAT COMMENT: PROVIDE ANY OUTSTANDING UTILITY
 LETTERS.
  
 12) PROVIDE DETAILS ON HOW THE GARBAGE/RECYCLING
 PICK-UP WILL WORK. CONDITION - GARBAGE RECEPTACLES MUST
 BE READY BEHIND THE GATE A HALF HOUR PRIOR TO THE
 SCHEDULED PICK-UP TIME. GARBAGE RECEPTACLES ARE THEN
 ROLLED OUT BY BUILDING MAINTENANCE PERSONNEL ONCE THE
 TRUCK ARRIVES. THE GARBAGE RECEPTACLES NEED TO BE MOVED
 BACK BEHIND THE GATE WITHIN A HALF HOUR OF PICK-UP BY
 BUILDING MAINTENANCE PERSONNEL.
  
 13) NEW COMMENT: PROVIDE ELEVATION DRAWINGS OF THE
 PROPOSED FENCES/WALLS WITHIN THE FRONT SETBACK.
  
 14) NEW COMMENT: PLEASE EXPLAIN WHAT IS OCCURRING ON
 THE PENTHOUSE ROOF DECK. THERE SEEMS TO BE A
 DISCREPANCY BETWEEN THE ELEVATION DRAWINGS AND THE
 "OPEN TO THE SKY" MECHANICAL AREAS.
  
 REQUIRED WAIVERS
  
 1) CURRIE CRESCENT SB
  
 2) WALL HEIGHTS:
  
 RETAINING WALL WEST OF NASSER IS 15 FOOT ABOVE HIS
 GRADE AT HIGHEST POINT
 ACACIA COURT RETAINING WALL + SAFETY RAIL IS 10+ FEET
 TALL IN SETBACK
 COLUMNS FOR FLAGLER DRIVE - 8 FEET --- STAFF DOES NOT
 SUPPORT
 WALLS ALONG CURRIE CRESCENT
  
 3) CURRIE CRESCENT ACCESS
 A. NUMBER
 B. SEPARATION
 C. ON-SITE MANEUVERING
  
 4) LANDSCAPE
 A. REQUIRED TREES
 B. BUFFER INTERRUPTION ALONG FLAGLER DRIVE.
  
  Print


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved