| Date |
Text |
| 2018-07-05 10:31:57 | CASE NO. PB 1799 & 1799A |
| | PROJECT NAME: 1309 SOUTH FLAGLER |
| | 1309 SOUTH FLAGLER |
| | |
| | - CONTACT ERIC SCHNEIDER @ (561) 822-1446 |
| | |
| | - PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN |
| | WRITTEN FORMAT. |
| | |
| | - WHEN RESUBMITTING, PLEASE PROVIDE A MINIMUM OF ELEVEN |
| | (11) PAPER COPIES AND AN ELECTRONIC COPY IN .PNG FORMAT |
| | OF ALL PLANS. PLEASE NOTE THAT CHANGES ON THE |
| | RESUBMITTED PLANS OR THE SUBMITTAL OF INFORMATION/PLANS |
| | TO ADDRESS THE COMMENTS MAY RESULT IN ADDITIONAL |
| | COMMENTS. |
| | |
| | - THE PPRC COMMENTS SHALL BE SUFFICIENTLY ADDRESSED AND |
| | SUBMITTED TO THE PLANNING DIVISION BY 5 PM ON FRIDAY, |
| | JULY 27, 2018, TO BE ELIGIBLE TO BE SCHEDULED FOR THE |
| | SEPTEMBER 20, 2018 PLANNING BOARD MEETING. |
| | |
| | - PLEASE NOTE THAT IF THE PLANNING DIVISION HAS NOT |
| | RECEIVED A RESPONSE TO THE PPRC COMMENTS WITHIN 60 DAYS |
| | FROM THE DATE OF THE PPRC MEETING (BY SEPTEMBER 11, |
| | 2018), THE CASE SHALL BE CONSIDERED WITHDRAWN. ANY |
| | FURTHER ACTION SHALL REQUIRE A NEW DEVELOPMENT |
| | APPLICATION. |
| | |
| | - PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1) |
| | RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY-ISSUED |
| | COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE |
| | APPLICANT WILL BE ASSESSED A RESUBMITTAL FEE. SUCH FEE |
| | WILL BE 20% OF THE ORIGINAL RPD APPLICATION FEE ($600). |
| | |
| | - PUBLIC HEARING NOTIFICATION SIGNAGE SHALL BE POSTED |
| | IN ACCORDANCE WITH THE REQUIREMENTS OF SECTION |
| | 94-39(I)(5) OF THE ZONING AND LAND DEVELOPMENT |
| | REGULATIONS. |
| | |
| | 1) PLANNING STAFF IS NOT SUPPORTING BUILDINGS IN EXCESS |
| | OF 300 FEET IN TOTAL HEIGHT, INCLUDING MECHANICAL |
| | EQUIPMENT, ALONG SOUTH FLAGLER DRIVE, SOUTH OF |
| | OKEECHOBEE BOULEVARD AS THIS IS NOT THE CHARACTER OF |
| | DEVELOPMENT IN THE AREA. THIS IS EVEN MAGNIFIED WHEN |
| | THE BUILDING REQUIRES WAIVERS TO THE SETBACKS BASED ON |
| | THE HEIGHT OF THE BUILDING. |
| | |
| | 2) THE FLOOR THAT IS LABELED AS BASEMENT LEVEL 1 IS |
| | ACTUALLY THE GROUND FLOOR; THEREFORE, THE BUILDING |
| | HEIGHT NEEDS TO BEGIN ITS MEASUREMENT FROM THE 3'8" |
| | NAVD SHOWN ON SECTION SHEET A3-02, NOT FROM CURRIE |
| | CRESCENT. |
| | |
| | 3) THE PROPOSED IMPROVEMENTS TO ACACIA ROAD NEED TO |
| | MEET THE ENGINEERING SERVICES DIVISION REQUIREMENTS |
| | PRIOR TO SCHEDULING THE CASE BEFORE THE PLANNING BOARD. |
| | |
| | A. PROVIDE A CROSS SECTION AND MORE DETAILS OF THE |
| | PROPOSED IMPROVEMENTS. THE CURRENT ELEVATION OF ACACIA |
| | ROAD IS SHOWN ON THE SURVEY SLOPING FROM APPROXIMATELY |
| | SIX (6) FEET TO 10 FEET ALONG THE NORTHERN PROPERTY |
| | BOUNDARY OF THE 1309 S. FLAGLER DEVELOPMENT SITE. THE |
| | SAME LOCATION IS SHOWN HAVING AN ALMOST CONSISTENT 10 |
| | FOOT ELEVATION. HOW IS THIS FOUR (4) FOOT GRADE CHANGE |
| | BEING INTEGRATED WITH THE PROPERTIES TO THE NORTH AND |
| | SOUTH OF THE SITE AS WELL AS TOWARD FLAGLER DRIVE. |
| | B. PROVIDE DETAILS OF THE PEDESTRIAN PERMEABLE PAVING |
| | AND THE BENCHES THAT ARE PROPOSED. |
| | C. PROVIDE DETAILS ON ADA ACCESSIBILITY. |
| | D. THE SKY BIKE CONTRACT IS WITH THE DDA AND DOES NOT |
| | EXTEND OUTSIDE OF DOWNTOWN. ALL OF THE BICYCLE SHARE |
| | FACILITIES NEED TO BE LOCATED ON THE 1309 S. FLAGLER |
| | PROPERTY. PLEASE NOTE THAT NO ADVERTISING FACILITIES |
| | WILL BE PERMITTED. SINCE THE BICYCLE SHARE IS BEING |
| | USED AS AN INNOVATIVE LAND PLANNING AND DEVELOPMENT |
| | TECHNIQUE TO CREATE MORE DESIRABLE AND ATTRACTIVE |
| | DEVELOPMENT IN ORDER TO RELAX THE HEIGHT/SETBACK |
| | REQUIREMENTS, THEN YOU WILL NEED TO PROVIDE |
| | DOCUMENTATION FROM SKY BIKE THAT THIS LOCATION IS |
| | ACCEPTABLE TO THEM (WITHOUT ADVERTISING), TO INCLUDE A |
| | PRELIMINARY AGREEMENT TO LOCATE THEIR FACILITIES OFF |
| | CURRIE CRESCENT PRIOR TO SCHEDULING THE CASE BEFORE THE |
| | PLANNING BOARD. |
| | E. THE 1309 SOUTH FLAGLER HOMEOWNER?S ASSOCIATION WILL |
| | NEED TO MAINTAIN ALL IMPROVEMENTS WITHIN THE ACACIA |
| | ROAD ROW AS WELL AS PROVIDE THE ELECTRICITY FOR THE |
| | LIGHTING. |
| | F. BOLLARD LIGHTING NEEDS TO BE USED ALONG THE PATH, |
| | NOT POLE MOUNTED LIGHTS. |
| | |
| | 4) THIS PROPERTY HAS DOUBLE FRONTAGE SO THE FRONT |
| | SETBACK IS MEASURED FROM BOTH FLAGLER DRIVE AND CURRIE |
| | CRESCENT. |
| | |
| | A. CURRIE CRESCENT IS A FRONT PROPERTY LINE AND THUS |
| | REQUIRES A 25 FOOT SETBACK. THE PLANS SHOW A 15 FOOT 4 |
| | INCH SETBACK FROM CURRIE CRESCENT. |
| | B. THE MAXIMUM WALL/FENCE HEIGHT WITHIN THE 25 FOOT |
| | FRONT SETBACK FROM CURRIE CRESCENT IS FOUR (4) FEET. |
| | |
| | 5) SHOW THE SETBACKS FROM THE PROPERTY LINES ON THE |
| | ELEVATION AND SECTION DRAWINGS. |
| | |
| | 6) THE SETBACK WAIVER TABLE PROVIDED IN THE |
| | JUSTIFICATION LETTER HAS ERRORS AND IS CONFUSING. EX. |
| | THE FRONT SETBACK IS 25 FEET BASED ON THE MF32 ZONING |
| | DESIGNATION; THEREFORE, NO FRONT SETBACK WAIVER IS |
| | NEEDED FROM FLAGLER DRIVE TO THE FRONT OF THE GROUND |
| | FLOOR (BASEMENT LEVEL 1 AND ITS OVERLOOK). |
| | |
| | 7) THE SURVEY SHOWS A SIX (6) FOOT WIDE UTILITY |
| | EASEMENT ALONG THE SOUTH PROPERTY LINE. THE LANDSCAPE |
| | BUFFER IS NOT PERMITTED TO BE PLANTED WITHIN THIS |
| | EASEMENT. THE REQUIRED BUFFER NEEDS TO BE LOCATED TO |
| | THE NORTH OF THE EASEMENT. PLEASE NOTE THAT THERE IS A |
| | STROMWATER LINE IN THIS AREA THAT THERE APPEAR TO BE |
| | TREES PLANTED ON TOP OF. |
| | |
| | 8) THE NUMBER OF REQUIRED BUFFER TREES WITHIN THE |
| | CURRIE CRESCENT BUFFER ARE NOT PROVIDED. |
| | |
| | 9) IN ORDER TO MAINTAIN THE OPEN CHARACTER OF SOUTH |
| | FLAGLER DRIVE, THE RECENT REDEVELOPMENT PROJECTS (LA |
| | CLARE AND BRISTOL) HAVE BEEN REQUIRED TO PROVIDE OPEN |
| | SPACE THAT IS PUBLICLY ACCESSIBLE AND THAT DOES NOT |
| | HAVE BARRIERS SUCH AS WALLS OR FENCES ALONG THEIR |
| | FLAGLER DRIVE FRONTAGES. THE PROPOSAL FAILS TO PROVIDE |
| | THIS OPEN SPACE, WHICH STAFF WILL NOT SUPPORT. |
| | |
| | 10) PROVIDE A PLAN WHICH DESCRIBES THE MATERIALS WHICH |
| | WILL BE USED ON THE BUILDING FACADES. |
| | |
| | 11) STAFF DOES NOT SUPPORT THE PROPOSED PROVISION OF |
| | INACTIVE/SERVICE USES THAT WILL BE AT THE ENTIRE |
| | PEDESTRIAN LEVELS ALONG CURRIE CRESCENT AND ACACIA |
| | ROAD. |
| | |
| | 12) STAFF DOES NOT SUPPORT THE 40 FOOT DRIVEWAY OPENING |
| | ALONG FLAGLER DRIVE. THIS CREATES AN UNNECESSARILY WIDE |
| | CROSSING POINT FOR PEDESTRIANS, WHICH DOES NOT PROMOTE |
| | SAFETY. ADDITIONALLY, USING MORE THAN A THIRD OF THE |
| | PROPERTY FRONTAGE FOR VEHICULAR ACCESS DOES NOT PROMOTE |
| | THE CITY'S AESTHETIC VISION FOR FLAGLER DRIVE. |
| | |
| | 13) THE REQUEST IS TO PERMIT TWO VEHICULAR ACCESS |
| | POINTS ALONG CURRIE CRESCENT. |
| | |
| | A. THE TWO ACCESS POINTS DO NOT MEET THE REQUIRED 125 |
| | FOOT SEPARATION DISTANCE BETWEEN ACCESS POINTS. |
| | B. WHY DO THERE NEED TO BE TWO CURB ACCESS POINTS? THE |
| | TWO ACCESS POINTS SHOULD BE CONSOLIDATED. |
| | C. WHY IS A VEHICULAR EXIT PROPOSED FROM THE LOBBY |
| | ENTRY TO CURRIE CRESCENT? PLEASE NOTE THAT YOUR TURNING |
| | RADIUS DRAWING SHOWS VEHICLES DRIVING IN FROM CURRIE |
| | CRESCENT. THIS IS NOT PERMITTED ON A ONE-WAY EXIT |
| | DRIVE. |
| | D. THE ZONING AND LAND DEVELOPMENT REGULATIONS REQUIRE |
| | THAT ALL VEHICULAR MOVEMENT AND MANEUVERING THAT MAY BE |
| | REQUIRED TO UTILIZE OFF-STREET PARKING FACILITIES SHALL |
| | BE RETAINED ON-SITE. PUBLIC RIGHTS-OF-WAY SHALL NOT BE |
| | UTILIZED TO ALLOW OR ENHANCE MOVEMENT OR MANEUVERING, |
| | WHICH IS THE REQUIRED BY THE WAY YOU ARE SHOWING YOUR |
| | LOADING AREA. |
| | |
| | 14) THE PLANS DO NOT CLEARLY SHOW THAT THE LANDSCAPE |
| | AREAS ARE BEING PROTECTED FROM VEHICULAR ENCROACHMENT |
| | BY A TYPE D CURB. |
| | |
| | 15) PROVIDE THE PHOTOMETRIC VALUES AT THE CURRIE |
| | CRESCENT PROPERTY LINE AND ALONG THE PROPERTY LINE |
| | ADJACENT TO THE RESIDENTIAL UNITS FOR PALM BEACH |
| | ATLANTIC UNIVERSITY AND 1301 SOUTH FLAGLER. THE |
| | LIGHTING LEVEL SHALL NOT EXCEED 1 FOOT CANDLE. |
| | |
| | 16) THE PHOTOMETRIC PLAN SHOWS AN EXCESS OF 1 FOOT |
| | CANDLE AT THE FLAGLER DRIVE PROPERTY LINE. |
| | |
| | 17) THE LIGHT POLES (TYPE V) NEED TO MEET THE 25 FOOT |
| | FRONT AND 15 FOOT SIDE SETBACKS. |
| | |
| | 18) PARKING |
| | |
| | A. THE VALET PARKING SPACE DETAIL DOES NOT CONFORM TO |
| | CITY STRIPING STANDARDS. ADDITIONALLY, YOU WILL NEED TO |
| | PROVIDE APPROVAL FROM THE CONSTRUCTION SERVICES |
| | DEPARTMENT THAT THE PROVISION OF PARKING SPACES AT THIS |
| | LOCATION DO NOT REQUIRE THE PROVISION OF ADA SPACES AS |
| | WELL. |
| | B. INCLUDE PARKING SPACE WIDTH DIMENSIONS ON THE SITE |
| | PLAN FOR GARAGE PARKING. |
| | C. SOME OF THE PARKING SPACES ARE VERY CLOSE TO THE |
| | SUPPORT COLUMNS. IN A FEW INSTANCES THERE IS ROOM TO |
| | SHIFT THE PARKING SPACE AWAY FROM THE COLUMN TO GIVE |
| | MORE ROOM, WHICH YOU SHOULD DO. THE SPACES BY THE RAMP |
| | IN BASEMENT 1 AND 2 AND ON BASEMENT 1 ACROSS FROM THE |
| | ADA SPACE (ADJACENT TO STORAGE) DO NOT APPEAR TO HAVE |
| | THE REQUIRED 8.5 FEET IN WIDTH (PLEASE DIMENSION) AND |
| | TWO SPACES HAVE THE COLUMN AT THE LOCATION WHERE A CAR |
| | DOOR WOULD OPEN, AND THUS REQUIRE EXTRA WIDTH. PLEASE |
| | NOTE THAT IF THESE COLUMNS HAVE NOT BEEN PROPERLY SIZED |
| | AS PART OF THIS SUBMITTAL AND GET LARGER AT THE TIME OF |
| | BUILDING PERMIT, IT MAY CAUSE A SUBSTANTIAL NUMBER OF |
| | PARKING SPACES TO BE IMPACTED, WHICH COULD LEAD TO |
| | PARKING DEFICIENCIES. |
| | D. PROVIDE VERIFICATION FROM THE CONSTRUCTION SERVICES |
| | DIVISION THAT THE LOCATION OF THE ADA SPACES IN THE |
| | GARAGE LEVELS CONFORM TO THE STANDARD THAT THEY ARE ON |
| | THE CLOSEST ACCESSIBLE ROUTE. |
| | E. THERE IS A DEAD END AISLE ON BASEMENT 1 THAT DOES |
| | NOT HAVE A FUNCTIONAL TURN AROUND SPACE - IT HAS A |
| | COLUMN IN IT. |
| | F. YOU WILL NEED TO PROVIDE ON-SIGHT EMPLOYEE PARKING |
| | FOR THE CONCIERGE, VALET, PERSONAL TRAINER, SPA |
| | ATTENDANT, ETC. |
| | G. PLEASE LABEL ON THE PLAN HOW THE PARKING WILL BE |
| | ASSIGNED ? EX. UNIT OWNER, GUEST, VALET, AND EMPLOYEE. |
| | H. THE PARKING TABLE NEEDS TO BE CORRECTED TO SEPARATE |
| | THE PARKING PROVIDED LINE INTO THE VARIOUS CATEGORIES |
| | AND THEN PROVIDE A TOTAL. PLEASE NOTE THAT TANDEM |
| | PARKING SPACES ONLY COUNT AS ONE SPACE TOWARD MEETING |
| | CITY CODE REQUIREMENTS. |
| | I. THE PARKING TABLE NEEDS TO HAVE LINE ITEMS FOR THE |
| | NUMBER OF ADA SPACES REQUIRED AND PROVIDED. |
| | |
| | 19) WHERE IS THE GARAGE VENTING? |
| | |
| | 20) BICYCLE FACILITIES. |
| | |
| | A. PLEASE NOTE THAT THE BICYCLE PARKING REQUIREMENT IS |
| | 1 SPACE PER 20 OF REQUIRED PARKING. WHILE STAFF |
| | ENCOURAGES THE PROVISION OF EXTRA BICYCLE PARKING, YOU |
| | ARE ONLY REQUIRED TO PROVIDE 5 BICYCLE PARKING SPACES. |
| | PLEASE SHOW THE REQUIRED AND THE PROVIDE NUMBERS AS |
| | SEPARATE LINE ITEMS ON THE PARKING TABLE. |
| | B. PROVIDE DETAILS OF THE BICYCLE STORAGE ROOM SO THAT |
| | STAFF CAN EVALUATE IF THE TYPE OF RACKS THAT ARE |
| | PROVIDED ARE APPROPRIATE FOR THE NUMBER OF SPACES |
| | C. AT LEAST ONE BICYCLE RACK NEEDS TO BE PROVIDE AT A |
| | GUEST OR EMPLOYEE ENTRANCE TO THE BUILDING FOR |
| | NON-RESIDENT USERS. PROVIDE A CITY COMPLIANT BICYCLE |
| | RACK DETAIL. |
| | |
| | 21) WHAT ARE THE AREAS LABELED SUITE 1 AND 2? |
| | |
| | 22) SHEET A3-02 SHOWS THE GENERATOR BELOW THE HEIGHT OF |
| | THE SCREENING. PLEASE BE AWARE THAT THE GENERATOR NEEDS |
| | TO BE SCREENED FOR ITS FULL HEIGHT, SO ENSURE THAT THE |
| | GENERATOR THAT IS USED IS NOT TOO LARGE TO AVOID ISSUES |
| | AT THE TIME OF PERMITTING. |
| | |
| | 23) THE JUSTIFICATION STATEMENT MENTIONS A TRAFFIC |
| | IMPACT STUDY, BUT STAFF DID NOT SEE ONE IN THE |
| | SUBMITTED MATERIAL. PLEASE PROVIDE THIS DOCUMENT. |
| | |
| | 24) PROVIDE ANY OUTSTANDING UTILITY LETTERS. |
| | |
| | 25) PLEASE EXPLAIN THE AREAS SHOWN AS STORAGE IN THE |
| | BASEMENT LEVELS. SOME APPEAR TO HAVE WALLS AND DOORS |
| | WHILE OTHERS JUST A DASHED LINE. |
| | |
| | 26) PROVIDE DETAILS ON HOW THE GARBAGE/RECYCLING |
| | PICK-UP WILL WORK. HOW HIGH IS THE CEILING IN THIS |
| | LOCATION? HOW WILL BULK ITEMS BE HANDLED? |
| | |
| | 27) PRIOR TO SUBMITTING FOR BUILDING PERMIT PLANS, YOU |
| | WILL NEED TO CONTACT MICHAEL ORIO, GIS SUPPORT |
| | SPECIALIST, AT (561) 494-1080, TO VERIFY THE SITE AND |
| | UNIT NUMBER ADDRESSING. |
| | |
| |
Print |