| Plan Review Notes For Project Z18060022 |
| Project Number |
Z18060022 |
|
| Review Stop |
SURVEY |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2018-07-09 10:49:37 | 1. PROVIDE FULL SIZE ORIGINAL OF SURVEY. | | | 2. ADJOINING SANITARY AND STORM NEEDS TO BE TELEVISED | | | BY APPLICANT. NEED PROPOSED AVERAGE AND PEAK WATER AND | | | SEWER FLOWS. | | | 3. NO EXFILTRATION TRENCHES WILL BE ALLOWED IN CURRIE | | | CRESCENT. | | | 4. NEED COPIES OF U.E.'S AND AGREEMENTS SHOWN ON | | | SURVEY. | | | 5. PROPERTY WILL NEED TO BE REPLATTED. | | | 6. PROPOSED STORM LINE IN FLAGLER NEEDS TO BE MOVED | | | ON-SITE. | | | 7. PROPOSED 8" WATER MAIN MAY NEED TO BE LOOPED BACK TO | | | OLIVE AVE. | | | 8. SEPARATE SUBMITTAL TO ENGINEERING FOR DEVELOPMENT | | | APPLICATION. | | | 9. WILL NEED MAINTENANCE AGREEMENT FOR ACACIA ROAD AND | | | CURRIE CRESCENT. | | | 10. SURVEY INCLUDES PROPERTY TO NORTH OF ACACIA WHICH | | | IS NOT INCLUDED IN SITE PLAN. |
| |
Print |
|