| Date |
Text |
| 2018-06-13 07:14:23 | THIS IS A CONCEPTUAL LEVEL REVIEW. CONSTRUCTION LEVEL |
| | DETAILS, DESIGN CALCULATIONS AND THE POLLUTION |
| | PREVENTION PLAN WILL BE REVIEWED AS PART OF THE |
| | ENGINEERING DEVELOPMENT APPROVAL AND BUILDING PERMIT |
| | APPLICATION PROCESSES. THE ENGINEERING DEVELOPMENT |
| | APPROVAL APPLICATION FORMS CAN BE DOWNLOADED AT HTTP:// |
| | WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS/FORMS,-PER |
| | MITS-APPLICATIONS |
| | |
| | THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO SITE |
| | PLAN APPROVAL: |
| | |
| | 1. ON PAVING, GRADING & DRAINAGE PLANS, REDUCE THE SIZE |
| | OF THE PROPERTY CORNER SYMBOLS SO AS TO NOT BE CONFUSED |
| | WITH THE CATCH BASIN SYMBOL. |
| | |
| | 2. CONSIDER REDUCING THE LENGTH OF THE PARKING SPACES |
| | AND PROVIDE TWO FEET OF OVERHANG IN THE LANDSCAPE |
| | AREAS. THIS WILL REDUCE THE AMOUNT OF ASPHALT AND |
| | INCREASE THE PERVIOUS AREA. |
| | |
| | 3. CONSIDER GRADING THE PARKING LOT TO DRAIN TO THE |
| | GREEN AREAS, ESPECIALLY IF THE LENGTH OF THE PARKING |
| | SPACES WILL BE REDUCED. |
| | |
| | 4. CONSIDER INCORPORATING LOW IMPACT DESIGN (LID) |
| | LANDSCAPING IN THE GREEN AREAS BETWEEN THE PARKING |
| | ROWS, ESPECIALLY IF #2 AND #3 ABOVE ARE ADOPTED. |
| | CONSIDER LID WITHIN THE DRY DETENTION AREA. |
| | |
| | 5. LABEL THE DRY RETENTION AREA AS DRY DETENTION AREA |
| | SINCE IT WILL HAVE AN OUTLET PIPE. |
| | THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO |
| | ISSUANCE OF CONSTRUCTION AUTHORIZATION INCLUDING |
| | BUILDING PERMITS AND ENGINEERING DEVELOPMENT APPROVAL. |
| | |
| | 1. AN ENGINEERING DEVELOPMENT APPROVAL APPLICATION WILL |
| | BE REQUIRED FROM THE ENGINEERING SERVICES DEPARTMENT. |
| | THE ENGINEERING DEVELOPMENT APPROVAL APPLICATION FORMS |
| | CAN BE DOWNLOADED AT: HTTP://WPB.ORG/DEPARTMENTS/ENGINE |
| | ERING-PUBLIC-WORKS/FORMS,-PERMITS-APPLICATIONS |
| | |
| | 2. PROVIDE SFWMD ERP MODIFICATION FOR THE DEVELOPMENT. |
| | |
| | 3. EROSION CONTROL PLAN AND DETAILS TO BE SUBMITTED |
| | WITH THE ENGINEERING PERMIT APPLICATION. |
| | |
| | |
| | TRACY WARD, PE |
| | SENIOR STORMWATER ENGINEER |
| | ENGINEERING SERVICES DEPARTMENT |
| | 561-494-1120 |
| | [email protected] |
| | |
| |
Print |