| Date |
Text |
| 2018-06-12 11:01:51 | SUNSET LOUNGE SITE PLAN (DATED 5-30-18) |
| | - THE COMMENTS ARE PRELIMINARY AS THE PLANS ARE MISSING |
| | KEY DIMENSIONS SUCH AS RADIUSES OF CURB RETURNS AND |
| | WIDTHS OF LANES ON STREETS. |
| | - LABEL RADIUSES OF CURB RETURNS. |
| | - PROVIDE TYPICAL SECTIONS FOR PUBLIC STREETS WITH |
| | DIMENSIONS |
| | - PROVIDE SIGNED AND SEALED SURVEY |
| | - REVISE SITE PLAN TO SHOW NORTH CURB LINE AND ANY CURB |
| | CUTS ON NORTH SIDE OF NINTH STREET |
| | - ON SITE ANGLE PARKING APPEARS TO BE 60 DEGREES. AISLE |
| | WIDTH IS TOO NARROW FOR 60 DEGREES. |
| | - LABEL ANGLE OF ANGLE PARKING WITH RESUBMITTAL |
| | - LIVE OAKS ARE PROPOSED UNDER POWER LINE ON NORTH |
| | ROSEMARY AVE. CHECK FPL REQUIREMENTS. |
| | - INTERNAL PARKING LOT. AISLE WIDTH DOESN?T MEET CITY |
| | STANDARD 24 FOOT. |
| | - INTERNAL PARKING LOT, SPACES ARE 9? WIDE. CITY CODE |
| | IS 8.5 FOOT WIDE. |
| | - EIGHT FOOT WIDE SIDEWALKS ARE REQUIRED FOR |
| | NON-RESIDENTIAL IN THE DOWNTOWN MASTER PLAN. |
| | - SHEET A0.04 COUNT OF ON-STREET PARALLEL PARKING |
| | SPACES IN PLAN VIEW IS INCORRECT. |
| | - ON-SITE, PROVIDE SIGHT TRIANGLE EXHIBIT FOR SIGHT |
| | LINE WITH DUMPSTER. |
| | - NINTH STREET. ON STREET PARKING SPACE IS TOO CLOSE TO |
| | FIRE HYDRANT. FLORIDA STATUTES 15? NO PARKING FROM |
| | HYDRANT. |
| | - SHEET A0.04 EIGHT ST. IS NOTED AS 60? ROW, BUT 50? |
| | PLOTTED. CLARIFY WHY THERE ARE TWO RIGHT OF WAY WIDTHS. |
| | - WHY ARE BIKE LANES PROPOSED ON 8TH STREET? |
| | - APPEARS ROSEMARY AVENUE IS SHIFTING THROUGH |
| | INTERSECTION OF EIGHT STREET TO ALLOW FOR PARALLEL |
| | PARKING ON WEST SIDE OF ROSEMARY AVE. PROVIDE DETAILS |
| | FOR ROADWAY TRANSITION. |
| | - ROSEMARY AVE. ON STREET PARKING SPACE IS 8? 8 INCHES |
| | WIDE. IT CAN BE REDUCED TO 8?. |
| | - ROSEMARY IS SHOWN WITH NINE FOOT LANES. PROVIDE 10 |
| | FOOT WIDE LANES. |
| | - WE DON'T SUPPORT SHIFTING OF ROSEMARY TO PROVIDE |
| | PARALLEL PARKING ON ONE SIDE AS THIS WILL MAKE IT |
| | DIFFICULT FOR THE OTHER SIDE OF THE STREET TO PROVIDE |
| | PARALLEL PARKING IN THE FUTURE. SUGGEST HOLDING ROADWAY |
| | CENTERLINE AND WIDEN ONSITE FOR PARALLEL PARKING. |
| | - WHO IS THE ENGINEER OF RECORD FOR THE ROADWAY |
| | IMPROVEMENTS? |
| | - CONSIDER ON-STREET ANGLED PARKING AROUND BUILDING AND |
| | PARK TO PROVIDE ADDITIONAL PARKING |
| | - SUGGEST ELIMINATING SOME ON-STREET PARKING ON 8TH |
| | STREET TO PROVIDE A PEDESTRIAN CONNECTION AT MIDBLOCK |
| | FROM THE SUNSET TO THE PARK |
| | - ARE STREET LIGHTS BEING PROPOSED? WHO WILL MAINTAIN |
| | THE STREET LIGHTS? |
| | - CODE OF ORDINANCES 94-305, TABLE X-1 ROSEMARY IS A |
| | THOROUGHFARE WITH A 30 FOOT RIGHT OF WAY SETBACK AND IS |
| | REQUIRED TO HAVE FOUR LANES. |
| | |
| | ERIK D. FERGUSON, P.E. |
| | CITY TRANSPORTATION ENGINEER |
| | 561-494-1092 |
| | [email protected] |
| | |
| |