Plan Review Notes
Plan Review Notes For Project Z18050029
Project Number Z18050029
Review Stop L
Sequence Number 2
Notes
Date Text
2018-12-14 16:10:21FROM: RAY CARANCI, LANDSCAPE PLANNER 561-822-1462
 PROJECT: CLEAR LAKE ESTATES RESIDENTIAL Z18050029
 DECEMBER 14, 2018
 I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND
 PROVIDE THE FOLLOWING COMMENTS:
  
 1. PARTIALLY SATISFIED. PROVIDE A TREE SURVEY, PROVIDE
 A PLAN WITH LOCATIONS OF EXISTING TREES, AND PROVIDE A
 TREE DISPOSITION CHART TO SHOW IF THEY WILL BE
 PRESERVED IN PLACE, RELOCATED OR REMOVED.
 TREE SURVEY NOT FOUND.
 CORRECTIONS TO TREE DISPOSITION PLAN ARE LISTED IN NEW
 COMMENTS.
  
 2. PARTIALLY SATISFIED. PROVIDE THE LANDSCAPE PLAN IN A
 MINIMUM SCALE OF 1:20.
 PLAN WAS SUBMITTED IN 1:30 SCALE AND IS STILL DIFFICULT
 TO DISCERN DETAILS. 1:20 WILL EXPAND THE NUMBER OF
 SHEETS BUT WILL BE EASIER TO READ DETAILS.
  
 3. SATISFIED. PROVIDE THE AMOUNT OF PROVIDED OPEN SPACE
 AND LANDSCAPE AREA ON THE LANDSCAPE PLAN.
  
 4. SATISFIED. SHOW THE CALCULATIONS FOR MINIMUM SHADE
 TREE AND FLOWERING TREE REQUIREMENTS PER SECTION
 94-443(C)(2)B. AND ADD REQUIRED TREES PER UNIT TO
 ESTABLISH THE MINIMUM TREES REQUIRED FOR THE SITE. OPEN
 SPACE REQUIRED FOR RESIDENTIAL ZONING INCLUDES
 SETBACKS, PARKING, SIDEWALKS, LANDSCAPE ISLANDS AND
 BUILDING PERIMETER PLANTINGS.
  
 5. PARTIALLY SATISFIED. SUBSTITUTION OF PALMS REQUIRES
 3:1 RATIO FOR COCONUT PALMS, REVISE ON CHART. PALMS
 SUBSTITUTION IS 102 NOT 132, REVISE ON CHART.
 PALMS ARE 3:1 OR 1:1. ADD UP ALL TRUNKS AT 3:1 AND THEN
 DIVIDE BY 3 TO GET TREE COUNT AND ADD 1:1 PALMS. IN MY
 REVIEW, THE COUNT CAME OUT TO PALMS SUBSTITUTED FOR 180
 TREES.
  
 6. SATISFIED. LIGUSTRUM DOES NOT QUALIFY AS A SHADE
 TREE. REVISE SHADE TREE COUNT.
  
 7. SATISFIED. PROVIDE THE REQUIRED 5 FOOT LANDSCAPE
 BUFFER PLANTINGS ALONG THE EAST PROPERTY LINE ADJACENT
 TO THE LAKE WITH THE REQUIRED TREES OR NUMBER OF
 SUBSTITUTE PALMS PER CURRENT CODE REQUIREMENTS OF
 SECTION 94-443(D).
  
 8. PARTIALLY SATISFIED. PLEASE INCLUDE ALL CALCULATIONS
 FOR THE EAST BUFFER AND NORTH BUFFER SEGMENTS ADJACENT
 TO THE ENTRANCE ON THE PERIMETER BUFFER REQUIREMENT
 CHART SO THAT LINEAR FOOTAGE OF ALL PROPERTY LINE
 SEGMENTS ARE INCLUDED.
 BUFFER SEGMENT ADJACENT TO THE ROAD NEEDS TO BE LISTED
 SEPARATELY, AS THIS HAS A REQUIRED 10 FOOT BUFFER,
 DIFFERENT FROM THE 5 FOOT REQUIRED BUFFER ON ALL OTHER
 SEGMENTS AND NEEDS TO INCLUDE REQUIRED TREES.
  
 9. PARTIALLY SATISFIED. PLEASE PROVIDE THE TREE AS
 REQUIRED IN THE TERMINAL LANDSCAPE ISLAND AT THE ENDS
 OF THE ROWS OF PARKING SPACES ADJACENT TO THE ENTRANCE
 TO BUILDING 4.
 TERMINAL ISLAND TREE IS REQUIRED AT THE SOUTH SIDE OF
 THE BUILDING, CANNOT BE DISPLACED BY A FIRE HYDRANT.
  
 10. SATISFIED. PLEASE CORRECT THE FLORIDA FRIENDLY
 LANDSCAPE CHART SO THAT TREES AND SHRUBS ARE NOT
 COUNTED TWICE FOR EACH CATEGORY OF NATIVE AND DROUGHT
 TOLERANT, AND CORRECT THE POINTS AWARDED FOR MULCH TO
 5. PROVIDE THE MINIMUM 50 POINTS.
  
 11. SATISFIED. PLEASE PROVIDE LOCATIONS OF LIGHTING ON
 THE LANDSCAPE PLAN TO AVOID CONFLICTS WITH LANDSCAPING.
  
 12. PARTIALLY SATISFIED. PLEASE SHOW LOCATIONS OF WATER
 AND SEWER LINES ON THE LANDSCAPE PLAN AND RESOLVE
 CONFLICTS WITH LANDSCAPING.
 THERE APPEAR TO BE CONFLICTS IN MULTIPLE LOCATIONS.
 EXPLAIN HOW THE 12 FOOT UTILITY EASEMENT ALONG THE WEST
 AND SOUTH PROPERTY LINE WILL ALLOW THE PLANTING OF
 BUFFER TREES AS PROPOSED.
 13. PARTIALLY SATISFIED. PROVIDE LOCATIONS AND
 SCREENING FOR ALL ABOVE GROUND UTILITY VALVES, BACKFLOW
 PREVENTERS, A/C UNITS, ETC.
 HEDGE SCREENING NOT SHOWN FOR BACKFLOWS AND VALVES, FPL
 TRANSFORMER LOCATIONS NOT SHOWN.
  
 14. PARTIALLY SATISFIED. SHOW LOCATIONS OF ANY ROOT
 BARRIERS REQUIRED TO PROTECT UTILITY LINES.
 SOME ROOT BARRIER LOCATIONS ARE SHOWN, BUT OTHERS
 APPEAR TO REQUIRE ROOT BARRIER DUE TO PROXIMITY.
  
 15. SATISFIED. PLEASE SHOW CALCULATIONS FOR EACH
 RESIDENTIAL BUILDING FOR COMPLIANCE WITH 40 PERCENT
 PERIMETER LANDSCAPE PER SECTION 94-443(E), AND 30
 PERCENT REQUIREMENT FOR THE PARKING DECK.
  
 16. SATISFIED. PLEASE SHOW COMPLIANCE WITH SECTION
 94-445 L. PLANT SPECIES. A MINIMUM OF 60 PERCENT OF
 PLANT MATERIAL ADDED SHALL BE FLORIDA NATIVE OR DROUGHT
 TOLERANT SPECIES SELECTED FROM THE CITY LIST OR THE
 LIST OF SPECIES IN THE MOST RECENT EDITION OF SOUTH
 FLORIDA WATER MANAGEMENT DISTRICT WATERWISE SOUTH
 FLORIDA LANDSCAPES.
 ADDITIONAL COMMENTS 12/14/18:
 17. THE FOLLOWING CORRECTIONS NEED TO BE MADE TO THE
 TREE DISPOSITION PLAN:
 ? 1:1 REPLACEMENT FOR SABAL PALMS IS CATEGORY 3 AT 100
 SQ FT. FOR EACH PALM TRUNK.
 ? #21 FICUS IS CATEGORY 1 AT 300 SQ FT.
 ? STAFF REVIEW OF CHART SHOWS TOTAL MITIGATION DUE IS
 9130 SQ FT.
 ? GIVE THE CONDITION OF SEAGRAPE TREE #31, AS ALL
 NATIVE TREES IN GOOD CONDITION MUST BE PRESERVED OR
 RELOCATED.
  
 CONDITIONS OF APPROVAL
 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON
 THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE
 SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT
 SERVICES DEPARTMENT, PLANNING DIVISION.
  
  Print