| 2018-08-30 13:03:23 | GENERAL COMMENTS: |
| | |
| | 1.) AS DISCUSSED AT THE 6/13 PPRC MEETING, THE |
| | APPLICANT INTENDS TO PROVIDE THE CROSS ACCESS AT A |
| | FUTURE DATE. STAFF WILL REQUIRE THE FOLLOWING: 1.) AN |
| | ALTERNATIVE SITE PLAN WITHOUT THE CROSS ACCESS (AS THE |
| | SUBMITTED PLANS SHOW A CROSS ACCESS POINT) PRIOR TO |
| | SITE PLAN APPROVAL, AND 2.) A CROSS ACCESS AGREEMENT |
| | BETWEEN PROPERTY OWNERS WILL BE REQUIRED PRIOR TO THE |
| | SUBMITTAL OF ANY BUILDING PERMITS ASSOCIATED TO |
| | DEVELOPING THE CROSS ACCESS. |
| | |
| | 2.) THE TWO (2) EXISTING POLE SIGNS ON THE SUBJECT |
| | PROPERTY ARE CONSIDERED LEGAL NONCOMPLYING SIGNS. THESE |
| | SIGNS SHALL BE REGULATED BY SECTION 94-404 OF THE |
| | ZONING AND LAND DEVELOPMENT REGULATIONS (ZLDRS), SHOULD |
| | THESE SIGNS BECOME OBSOLETE. |
| | |
| | 3.) ALL PRIVATE DEVELOPMENT PROJECTS, INCLUDING NEW |
| | CONSTRUCTION, OR THE RENOVATION OR IMPROVEMENT OF AN |
| | EXISTING BUILDING, WHERE THE TOTAL CONSTRUCTION COSTS |
| | ARE EQUAL TO OR GREATER THAN $750,000.00 IS SUBJECT TO |
| | THE ART IN PUBLIC PLACES REQUIREMENTS OF CHAPTER 78, |
| | ARTICLE V, OF THE CITY'S CODE OF ORDINANCES. |
| | |
| | 4.) ANY CHANGES TO THE PLANS SHALL BE REFLECTED IN ALL |
| | PLANS FOR CONSISTENCY. |
| | |
| | SITE PLAN COMMENTS: |
| | |
| | 1.) IT WAS NOTED BY STAFF AT THE 6/13 PPRC MEETING THAT |
| | THE CROSS ACCESS WOULD BE PROVIDED IN THE FUTURE. THE |
| | APPLICANT WAS REQUESTED TO PROVIDE ADDITIONAL PLANS |
| | WITH NO CROSS ACCESS, AS IT IS UNCERTAIN AT THIS TIME |
| | TO WHEN A CROSS ACCESS AGREEMENT WITH THE ADJACENT |
| | PROPERTY OWNER WOULD BE ESTABLISHED. THIS COMMENT HAS |
| | NOT BEEN ADDRESSED. [6/13/18 REPEAT COMMENT FROM PPRC] |
| | |
| | 2.) IDENTIFY THE LOCATION OF THE ANY MECHANICAL |
| | EQUIPMENT PROPOSED FOR THE PROJECT (I.E. A/C UNIT(S), |
| | GENERATORS, ETC.). MECHANICAL EQUIPMENT MAY NOT PROJECT |
| | MORE THAN 4 FT. INTO A SETBACK; ANY ROOFTOP EQUIPMENT |
| | SHALL BE SCREENED FROM PUBLIC VIEW BY A PARAPET OR WALL |
| | [ZLDR S.94-305(B)(4)]. [6/13/18 REPEAT COMMENT FROM |
| | PPRC] |
| | |
| | 3.) LIGHT FIXTURE PLACEMENT IN THE SITE PLAN DOES NOT |
| | MATCH THE LIGHT FIXTURE PLACEMENT IN THE PHOTOMETRIC |
| | AND CIVIL PLANS. PLEASE ADDRESS. |
| | |
| | 4.) THE MAXIMUM BUILDING HEIGHT (21'-2") SHALL BE |
| | INCLUDED IN THE SITE DATA TABULAR. |
| | |
| | LANDSCAPE PLAN COMMENTS: |
| | |
| | 1.) LIGHT FIXTURE PLACEMENT IN THE LANDSCAPE PLAN DOES |
| | NOT MATCH THE LIGHT FIXTURE PLACEMENT IN THE |
| | PHOTOMETRIC PLAN AND CIVIL PLANS. PLEASE ADDRESS. |
| | |
| | ARCHITECTURAL (FLOOR PLANS AND ELEVATIONS) COMMENTS: |
| | |
| | 1.) NEW STRUCTURES ALONG SOUTH DIXIE HIGHWAY SHOULD BE |
| | DESIGNED TO PROMOTE AND ENCOURAGE WALKABILITY ALONG THE |
| | SOUTH DIXIE CORRIDOR. BUILDING DESIGN ELEMENTS THAT CAN |
| | BE INCORPORATED TO IMPROVE PEDESTRIAN ACCESSIBILITY, |
| | INCLUDE: LOCATING STOREFRONTS/CUSTOMER ACCESS ALONG |
| | DIXIE HIGHWAY AND SOUTHERN BOULEVARD; MAXIMIZING |
| | BUILDING FRONTAGE ALONG STREET(S), AND BY PROVIDING |
| | GLAZING/TRANSPARENCY INTO STOREFRONTS. THE LAYOUT |
| | (FLOOR PLAN AND ELEVATIONS) OF THE PROPOSED BUILDING |
| | DOES NOT SEEM TO EXHIBIT DESIGN QUALITIES THAT PROMOTE |
| | PEDESTRIAN-ACTIVITY ALONG THESE STREETS. PLEASE |
| | ADDRESS. [NOTE: STAFF BELIEVES THAT THE NORTH (SOUTHERN |
| | BOULEVARD) AND WEST (S. DIXIE HWY) ELEVATIONS COULD BE |
| | IMPROVED TO FURTHER ENHANCE THE PEDESTRIAN SCALE. |
| | CONSIDER ADDITIONAL ARCHITECTURAL FEATURES (I.E. |
| | FENESTRATION, WINDOWS/OPENINGS, ETC.). |
| | |
| | 2.) ARCHITECTURAL PLANS SHALL BE SIGNED, DATED AND |
| | SEALED BY A FL REGISTERED ARCHITECT. REVISED |
| | ARCHITECTURAL PLANS HAVE NOT BEEN SIGNED, DATED AND |
| | SEALED. |
| | |
| | LIGHTING PLAN COMMENTS: |
| | |
| | 1.) ALL OUTDOOR LIGHTING SHALL BE SHIELDED TO REDUCE |
| | GLARE AND SHALL BE ARRANGED TO REFLECT LIGHT OR GLARE |
| | AWAY FROM ALL ADJACENT RESIDENTIAL DISTRICTS, ADJACENT |
| | RESIDENCES, OR PUBLIC THOROUGHFARES. A NOTE SHALL BE |
| | PROVIDED IN THE PLAN TO DEMONSTRATE COMPLIANCE [ZLDR |
| | S.94-309(A)]. [6/12/18 REPEAT COMMENT][NOTE: |
| | APPLICANT'S RESPONSE DATED 8/14/18 STATES THAT A NOTE |
| | HAS BEEN PROVIDED IN SHEET LP-1; HOWEVER, THAT COMMENT |
| | IS NOWHERE TO BE FOUND. ADDITIONALLY, THE NOTE SHOULD |
| | ALSO BE INCLUDED IN THE SITE AND PHOTOMETRIC PLANS] |
| | |
| | 2.) THE PLACEMENT OF THE LIGHT FIXTURES IN THE |
| | PHOTOMETRIC PLAN DOES NOT MATCH THE PLACEMENT OF THE |
| | LIGHT FIXTURES IN THE SITE AND LANDSCAPE PLANS. PLEASE |
| | ADDRESS FOR CONSISTENCY. |
| | |
| | INSTRUCTIONS FOR RESUBMITTAL: |
| | |
| | * PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN |
| | WRITTEN FORMAT. |
| | |
| | * WHEN RESUBMITTING, PLEASE PROVIDE A MINIMUM OF |
| | FIFTEEN (15) PAPER COPIES, ONE (1) REDUCED COPY IN 8.5 |
| | INCHES X 11 INCHES AND ONE (1) SET IN 11 INCHES X 17 |
| | INCHES, AND AN ELECTRONIC COPY OF ALL PLANS. |
| | |
| | * PLEASE NOTE THAT CHANGES ON THE RESUBMITTED PLANS MAY |
| | RESULT IN ADDITIONAL COMMENTS. |
| | |
| | * A $200 (20% OF THE ORIGINAL APPLICATION FEE) |
| | RESUBMITTAL FEE HAS BEEN ASSESSED FOR THE NEXT |
| | RESUBMITTAL. |
| | |
| | * CONTACT LINDA LOUIE @ (561) 822-1458 OR |
| | [email protected] IF THERE ARE QUESTIONS. |
| | |
| |