Plan Review Notes
Plan Review Notes For Project Z18030023
Project Number Z18030023
Review Stop L
Sequence Number 2
Notes
Date Text
2019-05-28 11:32:34FROM: RAY CARANCI, LANDSCAPE PLANNER 561-822-1462
 PROJECT: FLAMINGO HEALTH CLUB Z18040023
 MAY 24, 2019
 I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND
 PROVIDE THE FOLLOWING COMMENTS:
  
  
 1. NOT SATISFIED. PROVIDE A TREE SURVEY OF EXISTING
 TREES AND PALMS, INCLUDING ONES LOCATED IN THE EXISTING
 BISCAYNE DRIVE RIGHT OF WAY PROPOSED TO BE ABANDONED
 AND INCLUDED WITH THIS PLAN.
 THE TREES AND PALMS WITHIN THE PROPERTY LINE NEED TO BE
 IDENTIFIED FOR ACCURATE LOCATION.
  
 2. NOT SATISFIED. PROVIDE A TREE DISPOSITION PLAN.
 TREES WITHIN THE PROPERTY MUST BE IDENTIFIED AND SHOWN
 WHETHER THEY WILL REMAIN, BE REMOVED OR RELOCATED.
  
 3. NOT SATISFIED. PLEASE PROVIDE THE REQUIRED 5 FOOT
 LANDSCAPE BUFFER PLANTINGS ALONG THE EAST PROPERTY LINE
 ADJACENT TO THE OUTDOOR COURTS SHOWING THE REQUIRED
 TREES OR NUMBER OF SUBSTITUTE PALMS PER CURRENT CODE
 REQUIREMENTS OF SECTION 94-443(D).
 THE EXCEPTION IN SECTION 94-305 (B)(11) IS RELATED TO
 STRUCTURE SETBACKS OF ZERO FEET. IF BUILDING IS AT
 ZERO, THE REQUIRED LANDSCAPE BUFFER IS NOT POSSIBLE,
 BUT IF THERE IS NOT A BUILDING THE LANDSCAPE BUFFER IS
 REQUIRED.
 THE TENNIS COURTS ARE NOT STRUCTURES AND DO NOT HAVE
 SETBACKS.
  
 4. NOT SATISFIED. PLEASE INCLUDE ALL CALCULATIONS FOR
 THE EAST BUFFER PORTION ON THE LANDSCAPE REQUIREMENT
 CHART.
 SEE #3
  
 5. NOT SATISFIED. PLEASE CORRECT THE FLORIDA FRIENDLY
 LANDSCAPE CHART TO CURRENT CODE AND PROVIDE THE
 REQUIRED 50 POINTS.
 ? THE CHART DOES NOT REFLECT CODE CHANGES FROM 2018
 ? SHRUB POINTS CANNOT BE COUNTED 51% IN 2 CATEGORIES.
 TOTAL MUST BE 100% OR LESS.
  
 6. NOT SATISFIED. PLEASE PROVIDE LOCATIONS OF LIGHTING
 ON THE LANDSCAPE PLAN TO AVOID CONFLICTS WITH
 LANDSCAPING.
  
 7. NOT SATISFIED. PLEASE SHOW LOCATIONS OF WATER AND
 SEWER LINES ON THE LANDSCAPE PLAN AND RESOLVE CONFLICTS
 WITH LANDSCAPING.
  
 8. SATISFIED. CORRECT THE PLANT LIST TO SHOW 12 FOOT
 TREE SIZES PER CURRENT CODE.
  
 9. SATISFIED. SHOW THAT THE REQUIRED PARKING LOT TREES
 MEET THE 75% SHADE TREE REQUIREMENT.
 10. NOT SATISFIED. PLEASE SHOW COMPLIANCE WITH SECTION
 94-445 L. PLANT SPECIES. A MINIMUM OF 60 PERCENT OF
 PLANT MATERIAL ADDED SHALL BE FLORIDA NATIVE OR DROUGHT
 TOLERANT SPECIES SELECTED FROM THE CITY LIST OR THE
 LIST OF SPECIES IN THE MOST RECENT EDITION OF SOUTH
 FLORIDA WATER MANAGEMENT DISTRICT WATERWISE SOUTH
 FLORIDA LANDSCAPES.
 PROVIDE THE ACTUAL PERCENTAGE ON THE PLAN BASED ON THE
 PLANT LIST.
  
 11. PARTIALLY SATISFIED. PLEASE ADD COLUMNS TO THE
 PLANT LIST FOR NATIVE (Y OR N) AND DROUGHT TOLERANCE
 (HIGH, MEDIUM OR LOW), INSTEAD OF NOTES.
 ADD COLUMN FOR NATIVE FOR CLARITY AND EASE OF REVIEW.
  
 12. SATISFIED. LANDSCAPE PLAN, SITE PLAN AND
 ENGINEERING UTILITIES PLAN ARE NOT CONSISTENT FOR THE
 DUMPSTER/LIFT STATION AREA. PLEASE REVISE.
 ADDITIONAL COMMENTS 5/24/19:
  
 13. THERE ARE 12 PARKING SPACES IN A ROW AT THE
 NORTHWEST PORTION OF THE SITE. CODE LIMITS THE NUMBER
 TO MAXIMUM 10 IN A ROW.
 14. THE REQUIRED TREE IN THE TERMINAL LANDSCAPE ISLAND
 AT THE NORTHWEST CORNER MUST BE ADDED.
  
 CONDITIONS OF APPROVAL
 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON
 THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE
 SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT
 SERVICES DEPARTMENT, PLANNING DIVISION.
  