Plan Review Notes
Plan Review Notes For Project Z18030023
Project Number Z18030023
Review Stop STORM
Sequence Number 1
Notes
Date Text
2018-05-09 14:49:30THIS IS A CONCEPTUAL LEVEL REVIEW. CONSTRUCTION LEVEL
 DETAILS, DESIGN CALCULATIONS AND THE POLLUTION
 PREVENTION PLAN WILL BE REVIEWED AS PART OF THE
 ENGINEERING DEVELOPMENT APPROVAL AND BUILDING PERMIT
 APPLICATION PROCESSES. THE ENGINEERING DEVELOPMENT
 APPROVAL APPLICATION FORMS CAN BE DOWNLOADED AT HTTP://
 WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS/FORMS,-PER
 MITS-APPLICATIONS
  
 THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO SITE
 PLAN APPROVAL:
  
 1. THE PROPOSED STORM PIPE FROM THE INLET ON THE SOUTH
 SIDE OF BISCAYNE ROAD APPEARS TO CROSS THE ADJOINING
 PROPERTY. THE PIPE SHOULD BE WITHIN THE RIGHT-OF-WAY
 AND/OR APPLICANT?S PROPERTY WITHOUT THE NEED FOR A
 CONSTRUCTION EASEMENT.
  
 2. THE PROPOSED MANHOLE AND STORM PIPE ON FLAMINGO DR.
 NEEDS TO BE RELOCATED TO OUTSIDE THE RIGHT-OF-WAY. IT
 ONLY CONVEYS STORMWATER RUNOFF FROM THE APPLICANT?S
 PROPERTY.
  
 3. SHOW UTILITIES ON THE LANDSCAPE PLANS.
  
 4. ONSITE DRAINAGE SYSTEM TO PROVIDE FOR WATER QUALITY
 TREATMENT AND PEAK FLOW LIMITATION PER SFWMD CRITERIA
 FOR RUNOFF FROM THE PROJECT SITE.
  
 5. PERMIT WILL BE NEEDED TO WORK WITHIN THE F.E.C.
 RIGHT-OF-WAY.
  
 6. 2017 FEMA FIRM MAPS AND TWO FEET OF FREEBOARD ABOVE
 BASE FLOOD ELEVATION FOR STRUCTURES IN SPECIAL FLOOD
 HAZARD AREA ARE NOW IN EFFECT. THE MAPS ARE AVAILABLE
 AT HTTP://MAPS.CO.PALM-BEACH.FL.US/GIS/FLOODZONES.ASPX?
 UPDATE THE FLOOD ZONE INFORMATION ON THE BOUNDARY
 SURVEY.
  
 THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO
 ISSUANCE OF CONSTRUCTION AUTHORIZATION INCLUDING
 BUILDING PERMITS AND ENGINEERING DEVELOPMENT APPROVAL.
  
 1. AN ENGINEERING DEVELOPMENT APPROVAL APPLICATION WILL
 BE REQUIRED FROM THE ENGINEERING SERVICES DEPARTMENT.
 THE ENGINEERING DEVELOPMENT APPROVAL APPLICATION FORMS
 CAN BE DOWNLOADED AT: HTTP://WPB.ORG/DEPARTMENTS/ENGINE
 ERING-PUBLIC-WORKS/FORMS,-PERMITS-APPLICATIONS
  
 2. EROSION CONTROL PLAN AND DETAILS TO BE SUBMITTED
 WITH THE ENGINEERING PERMIT APPLICATION.
  
  
 3. PROVIDE SFWMD ERP FOR THE DEVELOPMENT.
  
 TRACY WARD, PE
 SENIOR STORMWATER ENGINEER
 ENGINEERING SERVICES DEPARTMENT
 561-494-1120