2018-06-22 14:54:40FROM: RAY CARANCI, LANDSCAPE PLANNER 561-822-1462
 PROJECT: OKEECHOBEE COMMERCIAL Z18020044
 JUNE 22, 2018
 I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND
 PROVIDE THE FOLLOWING COMMENTS:
  
  
 1. SATISFIED. PLEASE CORRECT THE TREE DISPOSITION LIST
 IDENTIFYING SPECIES AND TREE CANOPY DIAMETER OF TREES
 TO UPDATE TO CURRENT CODE REQUIREMENTS OF TREES LESS
 THAN 20 FOOT CANOPY ARE 1:1 REPLACEMENT, AND 20 FEET OF
 MORE MUST SHOW SQUARE FOOTAGE OF CANOPY REMOVED.
 PROVIDE A MITIGATION CHART SHOWING TOTAL CANOPY REMOVED
 AND REPLACED WITH PROPOSED PLAN. PLEASE SHOW MITIGATION
 PROVIDED ON THE SITE OF REMOVAL ONLY.
 THE DISPOSITION PLAN WAS NOT CORRECTED FOR CANOPY
 DIAMETER. PLEASE CORRECT AND SUPPLY A TOTAL FOR THE
 CANOPY PROPOSED TO BE REMOVED, AND TOTAL CANOPY
 PROVIDED.
 STAFF DOES NOT SUPPORT DESTRUCTION OF EXISTING SABAL
 PALMS. PLEASE USE THEM ON SITE.
  
 2. SATISFIED. PLEASE SHOW THE PROPERTY LINE DIVIDING
 THE PARCELS CLEARLY ON THE LANDSCAPE PLAN.
  
 3. SATISFIED. PLEASE PROVIDE SEPARATE LANDSCAPE
 CALCULATIONS FOR EACH PARCEL.
  
 4. SATISFIED. PLEASE CORRECT THE REQUIRED OPEN SPACE TO
 40 PERCENT OF THE TOTAL SITE, AND RECALCULATE REQUIRED
 TREES AND FLOWERING TREES TO CURRENT CODE OF 1 TREE PER
 1500 SQ FT OF REQUIRED OPEN SPACE OR PORTION THEREOF,
 AND FLOWERING TREES TO ONE PER 6000 SQ FT OR PORTION
 THEREOF.
  
 5. SATISFIED. PLEASE PROVIDE THE PERVIOUS LANDSCAPE
 AREA SQUARE FOOTAGE ON THE LANDSCAPE PLANS FOR BOTH
 PARCELS.
  
 6. SATISFIED. PLEASE CORRECT THE BUFFER REQUIREMENTS
 AND CALCULATIONS SHOWN ON THE PLAN. ONE TREE PER 30 LF
 OR PORTION THEREOF IS REQUIRED, SO SOUTH BUFFER IS 15
 TREES, AND EAST BUFFER IS 8 TREES.
  
 7. SATISFIED. PLEASE UPDATE FLORIDA FRIENDLY LANDSCAPE
 POINTS TO SHOW CURRENT APPLICABLE CODE REQUIRES 40
 POINTS, AND LIST HOW PROVIDED.
  
 8. SATISFIED. PLEASE SHOW CALCULATION OF PERCENTAGE OF
 PALMS SUBSTITUTED FOR REQUIRED TREES, NOT TO EXCEED 35
 PERCENT.
  
 9. SATISFIED. PLEASE SHOW CALCULATIONS FOR EACH
 BUILDING INDIVIDUALLY FOR COMPLIANCE WITH 30 PERCENT
 PERIMETER LANDSCAPING IN LINEAR FEET.
  
 10. SATISFIED. PLEASE EXPLAIN THE REASON FOR THE LONGER
 THAN 30 FOOT SPACING FOR THE BUFFER TREES ADJACENT TO
 THE ENTRANCE DRIVE FROM SKEES RD.
  
 11. SATISFIED. PLEASE SHOW LOCATIONS OF ANY FPL
 TRANSFORMERS ON THE LANDSCAPE PLAN.
  
 12. SATISFIED. PLEASE PROVIDE SCREENING FOR ALL GROUND
 MOUNTED EQUIPMENT AND UTILITIES. WATER BACKFLOW VALVES
 AND FPL TRANSFORMERS MUST HAVE SCREENING HEDGES.
  
 13. SATISFIED. PLEASE PROVIDE THE LOCATIONS OF LIGHTING
 ON THE LANDSCAPE PLAN TO PREVENT CONFLICTS WITH TREES.
 ADDITIONAL COMMENTS 5/1/18:
 14. SATISFIED. REQUIRED TREE IS MISSING IN TERMINAL
 ISLAND FOR ROW OF PARKING NORTH OF SKEES ROAD ENTRANCE.
  
 15. SATISFIED. WATER LINES NEED TO BE SHIFTED TO ALLOW
 REQUIRED TREES ADEQUATE ROOM IN THE LANDSCAPE ISLANDS.
  
 16. SATISFIED. BUFFER TREES FOR THE RESIDENTIAL PARCEL
 ON THE SOUTH SIDE OF THE FENCE NEED TO BE GRAYED OUT TO
 REPRESENT THAT THEY ARE NOT PART OF THE BUFFER FOR THIS
 PROJECT.
  
 CONDITIONS OF APPROVAL
 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON
 THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE
 SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT
 SERVICES DEPARTMENT, PLANNING DIVISION.
  