Plan Review Notes
Plan Review Notes For Project Z18020044
Project Number Z18020044
Review Stop L
Sequence Number 2
Notes
Date Text
2018-05-01 14:46:55FROM: RAY CARANCI, LANDSCAPE PLANNER 561-822-1462
 PROJECT: OKEECHOBEE COMMERCIAL Z18020044
 MAY 1, 2018
 I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND
 PROVIDE THE FOLLOWING COMMENTS:
  
  
 1. NOT SATISFIED. PLEASE CORRECT THE TREE DISPOSITION
 LIST IDENTIFYING SPECIES AND TREE CANOPY DIAMETER OF
 TREES TO UPDATE TO CURRENT CODE REQUIREMENTS OF TREES
 LESS THAN 20 FOOT CANOPY ARE 1:1 REPLACEMENT, AND 20
 FEET OF MORE MUST SHOW SQUARE FOOTAGE OF CANOPY
 REMOVED. PROVIDE A MITIGATION CHART SHOWING TOTAL
 CANOPY REMOVED AND REPLACED WITH PROPOSED PLAN. PLEASE
 SHOW MITIGATION PROVIDED ON THE SITE OF REMOVAL ONLY.
 THE DISPOSITION PLAN WAS NOT CORRECTED FOR CANOPY
 DIAMETER. PLEASE CORRECT AND SUPPLY A TOTAL FOR THE
 CANOPY PROPOSED TO BE REMOVED, AND TOTAL CANOPY
 PROVIDED.
 STAFF DOES NOT SUPPORT DESTRUCTION OF EXISTING SABAL
 PALMS. PLEASE USE THEM ON SITE.
  
 2. NOT SATISFIED. PLEASE SHOW THE PROPERTY LINE
 DIVIDING THE PARCELS CLEARLY ON THE LANDSCAPE PLAN.
  
 3. NOT SATISFIED. PLEASE PROVIDE SEPARATE LANDSCAPE
 CALCULATIONS FOR EACH PARCEL.
  
 4. NOT SATISFIED. PLEASE CORRECT THE REQUIRED OPEN
 SPACE TO 40 PERCENT OF THE TOTAL SITE, AND RECALCULATE
 REQUIRED TREES AND FLOWERING TREES TO CURRENT CODE OF 1
 TREE PER 1500 SQ FT OF REQUIRED OPEN SPACE OR PORTION
 THEREOF, AND FLOWERING TREES TO ONE PER 6000 SQ FT OR
 PORTION THEREOF.
  
 5. NOT SATISFIED. PLEASE PROVIDE THE PERVIOUS LANDSCAPE
 AREA SQUARE FOOTAGE ON THE LANDSCAPE PLANS FOR BOTH
 PARCELS.
  
 6. NOT SATISFIED. PLEASE CORRECT THE BUFFER
 REQUIREMENTS AND CALCULATIONS SHOWN ON THE PLAN. ONE
 TREE PER 30 LF OR PORTION THEREOF IS REQUIRED, SO SOUTH
 BUFFER IS 15 TREES, AND EAST BUFFER IS 8 TREES.
  
 7. NOT SATISFIED. PLEASE UPDATE FLORIDA FRIENDLY
 LANDSCAPE POINTS TO SHOW CURRENT APPLICABLE CODE
 REQUIRES 40 POINTS, AND LIST HOW PROVIDED.
  
 8. NOT SATISFIED. PLEASE SHOW CALCULATION OF PERCENTAGE
 OF PALMS SUBSTITUTED FOR REQUIRED TREES, NOT TO EXCEED
 35 PERCENT.
  
 9. NOT SATISFIED. PLEASE SHOW CALCULATIONS FOR EACH
 BUILDING INDIVIDUALLY FOR COMPLIANCE WITH 30 PERCENT
 PERIMETER LANDSCAPING IN LINEAR FEET.
  
 10. NOT SATISFIED. PLEASE EXPLAIN THE REASON FOR THE
 LONGER THAN 30 FOOT SPACING FOR THE BUFFER TREES
 ADJACENT TO THE ENTRANCE DRIVE FROM SKEES RD.
  
 11. NOT SATISFIED. PLEASE SHOW LOCATIONS OF ANY FPL
 TRANSFORMERS ON THE LANDSCAPE PLAN.
  
 12. NOT SATISFIED. PLEASE PROVIDE SCREENING FOR ALL
 GROUND MOUNTED EQUIPMENT AND UTILITIES. WATER BACKFLOW
 VALVES AND FPL TRANSFORMERS MUST HAVE SCREENING HEDGES.
  
 13. NOT SATISFIED. PLEASE PROVIDE THE LOCATIONS OF
 LIGHTING ON THE LANDSCAPE PLAN TO PREVENT CONFLICTS
 WITH TREES.
 ADDITIONAL COMMENTS 5/1/18:
 14. REQUIRED TREE IS MISSING IN TERMINAL ISLAND FOR ROW
 OF PARKING NORTH OF SKEES ROAD ENTRANCE.
  
 15. WATER LINES NEED TO BE SHIFTED TO ALLOW REQUIRED
 TREES ADEQUATE ROOM IN THE LANDSCAPE ISLANDS.
  
 16. BUFFER TREES FOR THE RESIDENTIAL PARCEL ON THE
 SOUTH SIDE OF THE FENCE NEED TO BE GRAYED OUT TO
 REPRESENT THAT THEY ARE NOT PART OF THE BUFFER FOR THIS
 PROJECT.
  
 CONDITIONS OF APPROVAL
 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON
 THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE
 SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT
 SERVICES DEPARTMENT, PLANNING DIVISION.
  
  Print