| Date |
Text |
| 2018-03-12 11:17:04 | GENERAL COMMENTS: |
| | 1. WRITTEN APPROVAL FROM THE LWDD WILL BE REQUIRED AS |
| | ONE OF THE PREREQUISITES FOR SITE PLAN APPROVAL. |
| | |
| | 2. A TPS LETTER STATING THAT THE PROPOSED COMMERCIAL |
| | PROJECT MEETS THE TRAFFIC PERFORMANCE STANDARDS (TPS) |
| | OF THE COUNTY WILL BE REQUIRED PRIOR TO SITE PLAN |
| | APPROVAL. |
| | |
| | SITE PLAN COMMENTS: |
| | |
| | 1. THE PARKING LOT AUTOMOBILE INTERNAL CIRCULATION |
| | INCLUDES A SERIES OF ONE-WAY DRIVES, TWO-WAY DRIVES AND |
| | DEAD END PARKING LOTS. PLEASE REVISE CIRCULATION FOR |
| | SAFETY AND PROVIDE TURN AROUNDS IN ANY DEAD END PARKING |
| | AREA. |
| | |
| | 2. THE PEDESTRIAN CONNECTION FROM THE RESIDENTIAL |
| | DEVELOPMENT TO THE COMMERCIAL PARCEL AT THE SOUTH END |
| | OF THE PROPERTY SHOULD PROVIDE A DIRECT CONNECTION TO |
| | THE COMMERCIAL BUILDINGS ENTRIES. |
| | |
| | 3. STRIPPING FOR PEDESTRIAN CROSSING AREAS SHOULD BE |
| | ADDED. |
| | |
| | 4. PEDESTRIAN CIRCULATION FROM SOUTH PARKING LOTS |
| | SHOULD BE ADDED. |
| | |
| | 5. CLEARLY IDENTIFY EXISTING AND PROPOSED SIDEWALK |
| | CONNECTIONS AND WIDTHS TO BOTH OKEECHOBEE AND SKEES |
| | ROAD. |
| | |
| | 6. IDENTIFY THE LOCATION OF ANY MECHANICAL EQUIPMENT |
| | (INCLUDING A/C UNITS). PLEASE NOTE THAT MUST MEET |
| | LANDSCAPE REQUIREMENTS (IF LOCATED ON THE GROUND). ANY |
| | ROOFTOP EQUIPMENT SHALL BE SCREENED FROM VIEW BY THE |
| | BUILDING?S PARAPET. [ZLDR S.94-305(A)(4)] |
| | |
| | 7. STRUCTURAL OVERHANGS SHALL NOT PROJECT EXTEND |
| | FARTHER THEN 3 FOOT INTO FRONT SETBACK. [ZLDR |
| | S.94-305(B)(2)]. PLEASE SHOW ON NORTH PROPERTY LINE. |
| | |
| | 8. A MINIMUM OF EIGHT (8) BICYCLE PARKING SPACES IS |
| | REQUIRED FOR THE PROJECT. PROVIDE BICYCLE PARKING AND A |
| | DETAIL THAT MATCHES THE PLAN. [ZLDR S.94-485(Q)] |
| | |
| | 9. NUMBER OF PARKING SPACES ON PLAN DIFFER FROM SITE |
| | DATA. PLEASE PROVIDE CALCULATION FOR NUMBER OF PARKING |
| | SPACES REQUIRED. |
| | |
| | 10. PROVIDE SEPARATE SITE DATA FOR BOTH THE DEVELOPMENT |
| | PARCEL AND THE LWDD TO MEET THE MINIMUM DEVELOPMENT |
| | REGULATIONS OF THE ZONING AND LAND DEVELOPMENT |
| | REGULATIONS (ZLDRS). |
| | |
| | 11. DETAIL OF THE DUMPSTER ENCLOSURE(S) SHALL MATCH THE |
| | DUMPSTER ENCLOSURE(S) ILLUSTRATED IN THE SITE PLAN DOES |
| | NOT MATCH ARCHITECTURAL PLAN. |
| | |
| | 12. IDENTIFY 6 FT. HIGH WALL AND GATE LOCATION ON THE |
| | RESIDENTIAL PARCEL THAT ABUTS THE COMMERCIAL PROPERTY. |
| | |
| | 13. SIGNAGE LOCATED ON LWDD WILL HAVE A CONDITION OF |
| | APPROVAL TO BE REMOVED IF AGREEMENT IS TERMINATED. |
| | |
| | 14. PROVIDE HIGH AND LOW FREE STANDING SIGN DETAILS AND |
| | SIGNAGE CALCULATIONS AND DIMENSIONS TO MEET ZLDR |
| | S.94-408(D). |
| | |
| | 15. PROVIDE DIMENSIONS FOR ALL WALL MOUNTED SIGNAGE ON |
| | BUILDINGS. |
| | |
| | LANDSCAPE PLAN COMMENTS: |
| | 1. BUILDING AND FRONT BUFFER LANDSCAPE REQUIREMENTS ARE |
| | SHALL BE PROVIDED. |
| | |
| | SITE LIGHTING: |
| | 1. PROVIDE A PHOTOMETRIC PLAN. ALL OUTDOOR LIGHTING |
| | SHALL BE SHIELDED TO REDUCE GLARE AND SHALL BE ARRANGED |
| | TO REFLECT LIGHT OR GLARE AWAY FROM THE ADJACENT |
| | RESIDENTIAL ZONING DISTRICT AND PUBLIC THOROUGHFARE. |
| | ANY GLARE SHALL BE CONDUCTED SO THAT DIRECT OR INDIRECT |
| | LIGHT FROM THE SOURCE SHALL NOT CAUSE ILLUMINATION IN |
| | EXCESS OF 0.5 FOOT CANDLES WHEN MEASURED IN A |
| | RESIDENTIAL DISTRICT. [ZLDR S.94-309(A) AND |
| | S.94-310(D)] |
| | |
| | INSTRUCTIONS FOR RESUBMITTAL: |
| | PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN WRITTEN |
| | FORMAT. |
| | |
| | WHEN RESUBMITTING, PLEASE PROVIDE A MINIMUM OF SIX (6) |
| | PAPER COPIES, ONE (1) REDUCED COPY IN 8.5 INCHES X 11 |
| | INCHES AND ONE (1) SET IN 11 INCHES X 17 INCHES, AND AN |
| | ELECTRONIC COPY OF ALL PLANS. PLEASE NOTE THAT CHANGES |
| | ON THE RESUBMITTED PLANS MAY RESULT IN ADDITIONAL |
| | COMMENTS. |
| | |
| | PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1) |
| | RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY-ISSUED |
| | COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE |
| | APPLICANT WILL BE ASSESSED A RESUBMITTAL FEE. SUCH FEE |
| | WILL BE 20 PERCENT OF THE ORIGINAL APPLICATION FEE |
| | ($200). |
| | |
| |
Print |