| 2018-05-25 15:34:45 | FROM: RAY CARANCI, LANDSCAPE PLANNER 561-822-1462 |
| | PROJECT: CHASE BANK 343 SOUTHERN BLVD Z18020024 |
| | MAY 25, 2018 |
| | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND |
| | PROVIDE THE FOLLOWING COMMENTS: |
| | |
| | |
| | 1. SATISFIED. PLEASE PROVIDE A TREE SURVEY AND A TREE |
| | DISPOSITION LIST IDENTIFYING SPECIES AND TREE CANOPY |
| | DIAMETER OF TREES AND PALMS, AND INDICATE WHETHER THEY |
| | WILL REMAIN, BE RELOCATED OR REMOVED. ALL CALCULATIONS |
| | AND DATA NEEDS TO BE UPDATED WHEN THE LOCATIONS AND |
| | SPECIES OF ANY TREES TO REMAIN ARE DETERMINED. |
| | THE 2 TREES ARE LIVE OAKS, AND CANOPY DIAMETER IS LESS |
| | THAN 20 FEET. |
| | |
| | 2. SATISFIED. PLEASE CORRECT THE REQUIRED OPEN SPACE TO |
| | 40 PERCENT OF THE TOTAL SITE, AND RECALCULATE REQUIRED |
| | TREES AND FLOWERING TREES TO CURRENT CODE OF 1 TREE PER |
| | 1500 SQ FT OF REQUIRED OPEN SPACE OR PORTION THEREOF, |
| | AND FLOWERING TREES TO ONE PER 6000 SQ FT OR PORTION |
| | THEREOF. |
| | |
| | 3. PLEASE PROVIDE THE PERVIOUS LANDSCAPE AREA SQUARE |
| | FOOTAGE ON THE LANDSCAPE PLAN. |
| | |
| | 4. SATISFIED. PLEASE CORRECT THE BUFFER REQUIREMENTS |
| | AND CALCULATIONS SHOWN ON THE PLAN. ACCORDING TO THE |
| | SURVEY, THE EAST AND WEST BUFFER LENGTHS ARE 105 FT, |
| | AND NORTH AND SOUTH ARE 225 FT. RECALCULATE TREE |
| | REQUIREMENTS AND SHOW HOW PROVIDED. |
| | |
| | 5. SATISFIED. PLEASE UPDATE FLORIDA FRIENDLY LANDSCAPE |
| | POINTS FOR THE FOLLOWING ITEMS: |
| | -CURRENT APPLICABLE CODE REQUIRES 40 POINTS. |
| | -PROVIDE AN AREA PLAN SHOWING HIGH, MEDIUM AND LOW |
| | WATER USE ZONES IF POINTS ARE CLAIMED. |
| | |
| | 6. SATISFIED. PALMS SUBSTITUTED FOR REQUIRED BUFFER |
| | TREES MUST BE AT A 3:1 RATIO FOR EACH TREE. |
| | |
| | 7. SATISFIED. PLEASE PROVIDE A TREE AS REQUIRED IN THE |
| | TERMINAL LANDSCAPE ISLAND FOR THE ROW OF PARKING |
| | ADJACENT TO THE DUMPSTER ENCLOSURE. |
| | |
| | 8. SATISFIED. PLEASE EXPLAIN THE REASON FOR THE LONGER |
| | THAN 30 FOOT SPACING FOR THE BUFFER TREES ADJACENT TO |
| | THE ATM. |
| | |
| | 9. SATISFIED. PLEASE SHOW LOCATIONS OF ANY FPL |
| | TRANSFORMERS ON THE LANDSCAPE PLAN. |
| | |
| | 10. SATISFIED. PLEASE SHOW LOCATIONS OF ROOT BARRIERS |
| | TO PROTECT INFRASTRUCTURE AND TREES FROM CONFLICTS. |
| | THIS INCLUDES WATER, SEWER, DRAINAGE, SIDEWALKS AND |
| | CURBS, AND ANY FIELD STRUCTURES THAT COULD BE IMPACTED |
| | BY TREE ROOTS. |
| | |
| | 11. SATISFIED. PLEASE PROVIDE SCREENING FOR ALL GROUND |
| | MOUNTED EQUIPMENT AND UTILITIES. WATER BACKFLOW VALVES |
| | AND FPL TRANSFORMERS MUST HAVE SCREENING HEDGES. PLEASE |
| | PROVIDE LANDSCAPE HEDGE ON THREE SIDES OF DUMPSTER |
| | ENCLOSURE AS REQUIRED. |
| | |
| | 12. SATISFIED. PLEASE PROVIDE THE LOCATIONS OF LIGHTING |
| | ON THE LANDSCAPE PLAN TO PREVENT CONFLICTS WITH TREES. |
| | |
| | CONDITIONS OF APPROVAL |
| | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON |
| | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE |
| | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT |
| | SERVICES DEPARTMENT, PLANNING DIVISION. |
| | |
| |
Print |