| 2018-06-08 11:09:03 | DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION, |
| | COMMENTS: |
| | |
| | 1. THIS REVIEW IS A CURSORY REVIEW AS IT RELATES TO THE |
| | SITE. IT IS NOT A REVIEW FOR FULL COMPLIANCE WITH |
| | FLORIDA BUILDING CODE. THE FOLLOWING COMMENTS ARE TO BE |
| | ADDRESSED FOR THE BUILDING PERMIT APPLICATION. |
| | |
| | 2. LOCATION OF ACCESSIBLE PARKING SPACES. THE RESPONSE |
| | LETTER DATED 5/8/18 FROM ZACH THORNTON, P.E., IS NOTED |
| | BUT DOES NOT ADDRESS THE COMMENT. SITE PLAN SHEET C7 |
| | SHOWS REGULAR PARKING SPACES LOCATED CLOSER TO THE |
| | BUILDING ENTRANCE THAN THE ACCESSIBLE PARKING SPACES. |
| | THE ACCESSIBLE PARKING SPACES SHALL BE RELOCATED SO |
| | THAT THEY ARE THE CLOSEST PARKING SPACES TO THE |
| | BUILDING ENTRANCE. PER SECTION 208.3 OF FLORIDA |
| | ACCESSIBILITY CODE, ACCESSIBLE PARKING SPACES ARE TO BE |
| | LOCATED ON THE SHORTEST POSSIBLE ROUTE OF TRAVEL FROM |
| | ADJACENT PARKING TO AN ACCESSIBLE ENTRANCE FOR EACH |
| | BUILDING. THIS IS A FLORIDA ACCESSIBILITY CODE |
| | REQUIREMENT BASED ON FEDERAL ADA, SO WE DO NOT HAVE |
| | DISCRETIONARY AUTHORITY. THE SUBMITTED COMMENT RESPONSE |
| | EXPLAINS WHY THIS REQUIREMENT HAS NOT BEEN MEET RATHER |
| | THAN OFFERING A SOLUTION THAT WILL MEET THE |
| | REQUIREMENT. THE FOLLOWING OPTION IS JUST A SUGGESTION |
| | SINCE YOU HAVE IMPLIED THAT THERE IS NO SOLUTION THAT |
| | COMPLIES WITH THE CODE REQUIREMENT. ONE OPTION WOULD BE |
| | TO RAISE THE ELEVATION OF THE ACCESS AISLE BETWEEN THE |
| | TWO ACCESSIBLE PARKING SPACES SO THAT THE SLOPE FROM |
| | THAT ACCESS AISLE, ACROSS THE WALKWAY LEADING TO THE |
| | BUILDING ENTRANCE IS NOT STEEPER THAN 1 IN 50 BUT |
| | SUFFICIENT TO DRAIN WATER AWAY FROM THE BUILDING |
| | ENTRANCE. THE SLOPES ACROSS THE PARKING SPACES AND |
| | DRIVE AISLE CAN THEN BE REWORKED TO ACCOMMODATE THIS |
| | ACCESSIBILITY REQUIREMENT. THIS COMMENT HAS BEEN RAISED |
| | NOW BECAUSE, IF NOT RESOLVED BEFORE PERMIT APPLICATION, |
| | IT WILL BECOME A PLAN REVIEW COMMENT THAT COULD |
| | POTENTIALLY AFFECT AN APPROVED SITE PLAN LAYOUT. |
| | |
| | 3. SEPARATE PERMITS REQUIRED. ALL APPLICABLE PERMITS |
| | AND SUB-PERMITS MUST BE OBTAINED BEFORE COMMENCING THE |
| | WORK. SEPARATE PERMITS, PLANS AND FEES, ARE REQUIRED |
| | FOR SIGNS, GAS SYSTEMS, GENERATORS, FIRE ALARM SYSTEMS, |
| | FIRE SPRINKLER AND OTHER FIRE SUPPRESSION SYSTEMS, |
| | GREASE INTERCEPTORS, SITE LIGHTING, SITE LANDSCAPE, |
| | SITE IRRIGATION, ETC. |
| | |
| | |
| | ROBERT BROWN |
| | BUILDING OFFICIAL |
| | TEL: 561 805 6652 |
| | EMAIL: [email protected] |
| | |
| |