| Date |
Text |
| 2018-02-13 18:08:34 | DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION, |
| | COMMENTS: |
| | |
| | 1. THIS REVIEW IS A CURSORY REVIEW AS IT RELATES TO THE |
| | SITE. IT IS NOT A REVIEW FOR FULL COMPLIANCE WITH |
| | FLORIDA BUILDING CODE. THE FOLLOWING COMMENTS ARE TO BE |
| | ADDRESSED FOR THE BUILDING PERMIT APPLICATION. |
| | |
| | 2. ACCESSIBLE PARKING. SHEET A1.0, SITE PLAN, SHOWS |
| | THAT 142 PARKING SPACES WILL BE PROVIDED SO 5 |
| | ACCESSIBLE PARKING SPACES ARE REQUIRED. THE SUBMITTED |
| | PLANS DO NOT SHOW 5 ACCESSIBLE PARKING SPACES AND ONLY |
| | SHOW 1 ACCESSIBLE PARKING SPACE ON THE MAIN ENTRY |
| | LEVEL. THE MINIMUM NUMBER OF ACCESSIBLE PARKING SPACES |
| | PROVIDED SHALL BE IN ACCORDANCE WITH SECTION 208.2 OF |
| | FLORIDA ACCESSIBILITY CODE. |
| | |
| | 3. VAN ACCESSIBLE PARKING. THE PLANS DO NOT CALL OUT |
| | THE LOCATION OF A VAN ACCESSIBLE PARKING SPACE. PER |
| | SECTION 208.2.4 OF FLORIDA ACCESSIBILITY CODE, ONE IN |
| | EVERY SIX ACCESSIBLE SPACES (AT LEAST ONE) IN A PARKING |
| | STRUCTURE, SHALL BE ?VAN ACCESSIBLE? AND DESIGNED IN |
| | ACCORDANCE WITH SECTION OF 502 OF FLORIDA ACCESSIBILITY |
| | CODE (VERTICAL CLEARANCE NOT LESS THAN 98 INCHES AT |
| | SPACE AND VEHICULAR ACCESS ROUTE) |
| | |
| | 4. LOCATION OF ACEESIBLE PARKING. CANNOT DETERMINE |
| | WHETHER THE ACCESSIBLE PARKING SPACES ARE CORRECTLY |
| | LOCATED BECAUSE SHEETS A2.1 AND A2.2, LEVEL 2 AND LEVEL |
| | 3 - OVERALL PLAN, DO NOT CLEARLY SHOW THE ENTRANCE TO |
| | THE BUILDING FROM THE PARKING GARAGE OR THE ROUTE TO |
| | THE ELEVATOR. PER SECTION 208.3 OF FLORIDA |
| | ACCESSIBILITY CODE, ACCESSIBLE PARKING SPACES ARE TO BE |
| | LOCATED ON THE SHORTEST POSSIBLE ROUTE OF TRAVEL FROM |
| | ADJACENT PARKING TO AN ACCESSIBLE ENTRANCE FOR EACH |
| | BUILDING. |
| | |
| | 5. BUILDING SIZE. WHEN SUBMITTED FOR BUILDING PERMIT, |
| | THE PLANS SHALL SHOW THAT THE TYPE OF CONSTRUCTION FOR |
| | THE BUILDINGS WILL BE IN ACCORDANCE WITH THE HEIGHT, |
| | AREA AND OCCUPANCY LIMITATIONS IN CHAPTER 5 OF THE |
| | FLORIDA BUILDING CODE. |
| | |
| | 6. BUILDING LOCATION RELATIVE TO THE PROPERTY LINE AND |
| | OTHER STRUCTURES. WHEN SUBMITTED FOR BUILDING PERMIT, |
| | COMPLIANCE WITH ALL BUILDING SEPARATION, PERCENTAGE OF |
| | OPENINGS AND OPENING PROTECTIVE REQUIREMENTS OF |
| | CHAPTERS 6 AND 7 OF THE FLORIDA BUILDING CODE SHALL BE |
| | VERIFIED. |
| | |
| | 7. IS THIS AN ENCLOSED PARKING GARAGE OR AN OPEN |
| | PARKING GARAGE? IF THE PARKING GARAGE DOES NOT HAVE |
| | WALL OPENINGS, OR SUFFICIENT WALL OPENINGS TO MEET THE |
| | DEFINITION OF AN OPEN PARKING GARAGE, IT WILL BE |
| | CONSIDERED AN ENCLOSED PARKING GARAGE AND MUST HAVE |
| | EXHAUST SYSTEMS. THE EXHAUST SYSTEMS SHALL BE DESIGNED |
| | TO MINIMIZE NOISE LEVELS USING INLINE FAN SILENCERS OR |
| | OTHER APPROVED METHODS. |
| | |
| | 8. LEVEL 2 EGRESS FROM PARKING GARAGE. SHEET A2.1, |
| | LEVEL 2 - OVERALL PLAN, DOES NOT SHOW A ROUTE FOR |
| | OCCUPANTS ON LEVEL 2 OF THE PARKING GARAGE TO GET TO |
| | THE EAST STAIR. |
| | |
| | 9. SEPARATE PERMITS REQUIRED. ALL APPLICABLE PERMITS |
| | AND SUB-PERMITS MUST BE OBTAINED BEFORE COMMENCING THE |
| | WORK. SEPARATE PERMITS, PLANS AND FEES, ARE REQUIRED |
| | FOR SIGNS, GAS SYSTEMS, GENERATORS, FIRE ALARM SYSTEMS, |
| | FIRE SPRINKLER AND OTHER FIRE SUPPRESSION SYSTEMS, |
| | GREASE INTERCEPTORS, SITE LIGHTING, SITE LANDSCAPE, |
| | SITE IRRIGATION, ETC. |
| | |
| | 10. THIS PROJECT WILL BE SUBJECT TO ART IN PUBLIC |
| | PLACES (AIPP) ASSESSMENT. FOR ADVICE ON THE PROVISION |
| | OF PUBLIC ARTWORK IN LIEU OF THE AIPP ASSESSMENT, |
| | CONTACT SYBILLE WELTER, ART IN PUBLIC PLACES |
| | COORDINATOR, AT (561) 822-1521, OR BY EMAIL: |
| | [email protected] |
| | |
| | ROBERT BROWN |
| | BUILDING OFFICIAL |
| | TEL: 561 805 6652 |
| | EMAIL: [email protected] |
| | |
| |
Print |