| Date |
Text |
| 2018-02-13 17:19:04 | FROM: RAY CARANCI, LANDSCAPE PLANNER 561-822-1462 |
| | PROJECT: 3111 S DIXIE Z18010012 |
| | FEBRUARY 13, 2018 |
| | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND |
| | PROVIDE THE FOLLOWING COMMENTS: |
| | |
| | 1. PLEASE CORRECT THE TREE DISPOSITION PLAN SHEET TS-2 |
| | FOR THE FOLLOWING: |
| | ? IDENTIFY ALL TREES CORRECTLY FOR SPECIES. REFERENCE |
| | THE PREVIOUS PLAN. |
| | ? AS A SIGNIFICANT NUMBER OF EXISTING TREES ON SITE |
| | WERE PREVIOUSLY GOOD CANDIDATES FOR RELOCATION, PROVIDE |
| | ALL INFORMATION ON CONDITION OF EXISTING TREES. |
| | ? TREES TO BE RELOCATED NEED TO BE TAGGED WITH THEIR |
| | IDENTIFYING NUMBER, AND LOCATION SHOWN BY NUMBER ON THE |
| | PROPOSED LANDSCAPE PLAN. |
| | ? PROVIDE THE TREE CANOPY DIAMETER FOR EACH TREE ON THE |
| | DISPOSITION CHART. |
| | ? CORRECT THE MITIGATION CHART AFTER ALL CORRECTIONS |
| | ABOVE ARE MADE. |
| | |
| | 2. PLEASE PROVIDE A SEPARATE PLAN SHOWING THE LANDSCAPE |
| | BUFFER WIDTHS PROPOSED AND WHAT IS REQUIRED BY CODE IN |
| | ORDER TO CLEARLY DEFINE THE BUFFER REQUESTS. |
| | |
| | 3. REQUIRED LANDSCAPE BUFFER WIDTHS ARE 10 FEET FOR THE |
| | EAST AND SOUTH BUFFER, AND 5 FEET FOR THE WEST AND |
| | NORTH BUFFER. PLEASE CORRECT WAIVER #1 ON THE SITE PLAN |
| | AND NARRATIVE. |
| | |
| | 4. PLEASE ACCOUNT FOR THE REQUIRED TREES ON ALL 4 |
| | BUFFER LENGTHS, AND INDICATE IF ANY WILL BE ELIMINATED |
| | THROUGH THE WAIVER REQUESTS. |
| | |
| | 5. CPD ZONING REQUIRES 20% LANDSCAPE AREA. PERVIOUS |
| | PAVERS CANNOT BE COUNTED AS LANDSCAPE AREA. CURBS MAY |
| | BE RELOCATED WITHIN THE PARKING SPACE TO A LOCATION TO |
| | PROVIDE A LANDSCAPED PERVIOUS OVERHANG AREA, AND |
| | ELIMINATE WHEEL STOPS. |
| | |
| | 6. PLEASE CORRECT CALCULATIONS FOR THE BUFFER TREES |
| | REQUIRED FOR THE SOUTH BUFFER TO 14 REQUIRED. |
| | |
| | 7. THE DATA PROVIDED IN THE LANDSCAPE CALCULATIONS |
| | CHART ON SHEET LP-6 NEEDS TO BE CORRECTED TO REFLECT |
| | CURRENT CODE REQUIREMENTS FOR THE REQUIRED TREES FOR |
| | OPEN SPACE AND THE FLORIDA FRIENDLY POINTS |
| | REQUIREMENTS. PLEASE PROVIDE THE REQUIRED NUMBER OF |
| | TREES ON THE LANDSCAPE PLAN. |
| | 8. PLEASE CORRECT THE OPEN SPACE AREA USED FOR |
| | CALCULATING TREE AND SHRUB REQUIREMENTS TO 40% OF THE |
| | TOTAL SITE AREA. THIS IS 163223 SQ. FT. NOT 81021 AS |
| | LISTED. |
| | |
| | 9. PLEASE SHOW THE TOTAL INTERIOR LANDSCAPE AREA |
| | REQUIRED FOR SECTIONS 94-443(C)3 AND (C)4 AND INCLUDE A |
| | PLAN SHOWING LOCATIONS OF PROVIDED AREA. |
| | |
| | 10. PLEASE SHOW COMPLIANCE WITH 40 PERCENT BUILDING |
| | LANDSCAPING PER SECTION 94-443(D)(2)B FOR EACH OF THE |
| | RESIDENTIAL BUILDINGS, AND 30 PERCENT PER SECTION |
| | 94-443(E)(1) FOR EACH OF THE COMMERCIAL BUILDINGS. |
| | |
| | 11. PLEASE PROVIDE A CONTINUOUS HEDGE AROUND THE THREE |
| | NON-ACCESS SIDES OF ALL DUMPSTER ENCLOSURES. |
| | |
| | 12. PLEASE PROVIDE THE REQUIRED TERMINAL LANDSCAPE |
| | ISLAND FOR THE ROWS OF PARKING TO THE NORTH OF THE |
| | DUMPSTER ENCLOSURE AT THE SOUTHWEST CORNER OF THE SITE, |
| | SHEET LP-2. |
| | |
| | 13. PLEASE PROVIDE THE REQUIRED TERMINAL LANDSCAPE |
| | ISLAND FOR THE ROW OF PARKING ADJACENT TO THE ADA |
| | SPACE, SHEET LP-3. |
| | |
| | 14. STREET TREES LOCATED IN TREE GRATES IN A SIDEWALK |
| | OR PAVED AREA SHALL HAVE STRUCTURAL SOIL EXTENDING 5 |
| | FEET IN ALL DIRECTIONS AND UP TO THE CURB. INDICATE |
| | STRUCTURAL SOIL LOCATIONS ON THE LANDSCAPE PLAN AND |
| | PROVIDE A TYPICAL STRUCTURAL SOIL DETAIL ON THE |
| | LANDSCAPE DETAIL PAGE. |
| | |
| | 15. PLEASE ADJUST THE REQUIRED SIZE OF THE LIGUSTRUM, |
| | CORDIA, CALYPTRANTHES, LAGERSTROEMIA MUSKOGEE AND |
| | STEMMADENIA TO 12 FEET OR PROVIDE DOCUMENTATION THAT |
| | THIS SIZE IS NOT AVAILABLE. |
| | |
| | 16. DURANTA ERECTA IS NOT DOCUMENTED AS A FLORIDA |
| | NATIVE PLANT. PLEASE REVISE ON PLANT LIST. |
| | |
| | 17. PHILODENDRON ROJO CONGO AND STENOTAPHRUM DO NOT |
| | HAVE THE NATIVE OR DROUGHT TOLERANT COLUMNS COMPLETE ON |
| | THE PLANT LIST. PLEASE REVISE. |
| | |
| | 18. PLEASE SHOW LOCATIONS OF ROOT BARRIERS TO PROTECT |
| | INFRASTRUCTURE AND TREES FROM CONFLICTS. THIS INCLUDES |
| | WATER, SEWER, DRAINAGE, SIDEWALKS AND CURBS, AND ANY |
| | FIELD STRUCTURES THAT COULD BE IMPACTED BY TREE ROOTS. |
| | |
| | 19. PLEASE SHOW LOCATIONS OF ALL GROUND MOUNTED |
| | EQUIPMENT INCLUDING FPL TRANSFORMERS, A/C UNITS, ETC., |
| | AND PROVIDE SCREENING FOR ALL GROUND MOUNTED EQUIPMENT |
| | AND UTILITIES. |
| | |
| | PLEASE UNDERSTAND THAT ADDITIONAL INFORMATION MAY BE |
| | REQUESTED, AND STAFF MAY HAVE ADDITIONAL COMMENTS AS |
| | THE REVIEW PROCESS CONTINUES. |
| | CONDITIONS OF APPROVAL |
| | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON |
| | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE |
| | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT |
| | SERVICES DEPARTMENT, PLANNING DIVISION. |
| | 2. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE |
| | RESPONSIBLE FOR THE PERMITTING AND INSTALLATION OF THE |
| | STREET TREES, TREE GRATES, RIGHT OF WAY LANDSCAPING AND |
| | IRRIGATION APPROVED WITH THIS PETITION. |
| | 3. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE |
| | RESPONSIBLE FOR THE MAINTENANCE OF THE ROAD RIGHT OF |
| | WAY LANDSCAPING, TREE GRATES AND IRRIGATION ADJACENT TO |
| | THE PROPERTY. THIS WILL BE THROUGH A SEPARATE |
| | MAINTENANCE AGREEMENT WITH THE CITY. |
| | |
| |