Plan Review Notes
Plan Review Notes For Project Z17120025
Project Number Z17120025
Review Stop Z
Sequence Number 2
Notes
Date Text
2018-03-23 12:21:30CASE NUMBER: PB 1773, 1773A, 1773B
 PROJECT NAME: 1701 CLARE AVE
  
 ZONING CONTACT: HEATHER M. TRIBOU
  (561) 822-1562
  [email protected]
  
 PROCESS COMMENTS
  
 - PLEASE PROVIDE RESPONSES TO ALL REVIEW COMMENTS IN
 WRITTEN FORMAT.
  
 - WHEN RESUBMITTING, PLEASE PROVIDE AN ELECTRONIC
 COPIES IN PDF FORMAT OF ALL PLANS. NUMBER OF PAPER
 COPIES TO BE RESUBMITTED WILL DEPEND ON REVIEWER
 COMMENTS. PLEASE NOTE THAT CHANGES ON THE RESUBMITTED
 PLANS OR THE SUBMITTAL OF INFORMATION/PLANS TO ADDRESS
 THE COMMENTS MAY RESULT IN ADDITIONAL COMMENTS.
  
 - THE PPRC COMMENTS SHALL BE SUFFICIENTLY ADDRESSED AND
 SUBMITTED TO THE PLANNING DIVISION BY 5 PM ON FRIDAY,
 APRIL 27, 2018, TO BE SCHEDULED FOR THE JUNE 19, 2018
 PLANNING BOARD MEETING.
  
 - PLEASE NOTE THAT IF THE PLANNING DIVISION HAS NOT
 RECEIVED A RESPONSE TO THE PPRC COMMENTS WITHIN 60 DAYS
 FROM THE DATE OF THESE COMMENTS (BY MAY 22, 2018), THE
 CASE SHALL BE CONSIDERED WITHDRAWN. ANY FURTHER ACTION
 SHALL REQUIRE A NEW DEVELOPMENT APPLICATION.
  
 - PLEASE NOTE THAT YOU HAVE BEEN PERMITTED ONE (1)
 RESUBMITTAL AT NO ADDITIONAL COST. PREVIOUSLY ISSUED
 COMMENTS HAVE NOT BEEN SUFFICIENTLY ADDRESSED,
 THEREFORE THE APPLICANT WILL BE ACCESSED A RESUBMITTAL
 FEE. SUCH FEE WILL BE 20% OF THE ORIGINAL APPLICATION
 FEE ($600).
  
 - PUBLIC HEARING NOTIFICATION SIGNAGE SHALL BE POSTED
 IN ACCORDANCE WITH THE REQUIREMENTS OF SECTION
 94-39(I)(5) OF THE ZONING AND LAND DEVELOPMENT
 REGULATIONS.
  
 GENERAL COMMENTS
  
 -- THE SCHOOL DISTRICT OF PALM BEACH COUNTY? SCHOOL
 CAPACITY AVAILABILITY DETERMINATION RECOMMENDS THE
 FOLLOWING CONDITION.
  
 ?IN ORDER TO ADDRESS THE SCHOOL CAPACITY DEFICIENCY
 CREATED BY THIS PROPOSED DEVELOPMENT AT THE DISTRICT
 MIDDLE AND HIGH SCHOOL LEVEL, THE PROPERTY OWNER IS
 REQUIRED TO CONTRIBUTE A TOTAL OF $27,740 TO THE SCHOOL
 DISTRICT OF PALM BEACH COUNTY PRIOR TO ISSUANCE OF
 FIRST BUILDING PERMIT. THIS SCHOOL CAPACITY
 CONTRIBUTION IS INTENDED TO SUPPLEMENT THE REQUIRED
 SCHOOL IMPACT FEE (IMPACT FEE CREDIT HAS ALREADY BEEN
 APPLIED).?
  
 --COMPREHENSIVE PLAN TRAFFIC IMPACT STUDY TABLES ARE
 INCORRECTLY LABELED AS DWELLING UNITS FOR SQUARE
 FOOTAGE TOTALS. (PG. 2)
  
 --PARKING STUDY RECOMMENDS 290 PARKING SPACES, WHICH IS
 LESS THEN CODE. PLANS ONLY PROVIDE 253 SPACES WHICH IS
 LESS THEN PARKING STUDY. PLEASE ADDRESS.
  
 -- PHASE 1 ENVIRONMENTAL REPORT- REC?S STATED MUST BE
 ADDRESSED BEFORE ISSUANCE OF BUILDING PERMIT.
  
 --WORKFORCE HOUSING- THE VOLUNTARY WORKFORCE HOUSING
 COMMITMENT IS COMMENDABLE IN THE BURGEONING NEW AREA,
 BUT NEEDS FURTHER DEVELOPMENT/ DISCUSSION. TOPICS
 INCLUDE HOW LONG THE WORKFORCE HOUSING WILL BE
 MAINTAINED. HOW THE COMMITMENT RELATES TO CURRENT
 MARKET RATES AND THE NUMBER OF UNITS. A TRUE COMMITMENT
 WOULD BE 20% AT 140% AMI FOR 15 YEARS OR 10% AT 120%
 AMI FOR 15 YEARS. THIS WILL BE A RECORDED RESTRICTION.
  
 SPECIFIC COMMENTS
  
 --FSP-1- PROVIDE MORE DETAIL ON TRASH SERVICE.
 CURRENTLY THE PLANS INDICATE ROLLING THE TRASH OUT OF
 THE FRONT ENTRY OF MULTIPLE UNITS. PLEASE CHECK SIZING
 OF DUMPSTERS AND VERIFY LOCATION SIZE IS ADEQUATE AND
 IF EXTRA SCREENING WILL BE NEEDED TO BLOCK THE VIEW
 FROM THE FRONT DOOR OF THE RESIDENTIAL UNITS.
  
 --FSP-1- PROVIDE SIDEWALK WIDTH DIMENSIONS FOR
 PEDESTRIAN EXIT LOCATIONS.
  
 --FSP-1- SIDEWALK AT WILKINS AVE AND CLARE PINCHES DOWN
 IN SIZE. PLEASE UPDATE RADIUS AT CORNER.
  
 --FSP-1 & ARCHITECTURAL PLANS- THE ACCESS DRIVE TO THE
 PARKING GARAGE DOES NOT MEET MINIMUM STANDARDS WHICH IS
 24 FEET. (SEC. 94-846)
  
 --FSP-1 & ARCHITECTURAL PLANS- PARKING COMPUTATIONS ON
 SITE PLAN DIFFER THEN ACTUAL SPACES. STAFF COUNTED 35
 ON-STREET PARKING SPACES AND 219 IN THE PARKING GARAGE.
  
 --FSP-1-LOCATE SIGNAGE ON SITE PLAN.
  
 --FSP-1- PLEASE PROVIDE SITE AMENITIES IN RESIDENTIAL
 SIDE PARK.
  
 --FSP-2- PROVIDE DETAILS FOR FENCES.
  
 --ARCHITECTURAL PLANS- PLANS FOR AMENITIES ON 3RD LEVEL
 ARE JUST A SET OF UNLABELED BOXES.
  
 --ARCHITECTURAL PLANS- LABEL PLANTERS TO INDICATE
 RELATIONSHIP WITH CONCEPTUAL RENDERINGS
  
 --ARCHITECTURAL PLANS- TWO GROUND FLOOR UNITS DO NOT
 HAVE ACCESS FROM THE PARKING GARAGE.
  
 --ROADWAY BEATIFICATION PLAN- PROVIDE LANDSCAPE IN BULB
 OUTS ON CLARE. IF UTILITY CONFLICT EXISTS PROVIDE
 TYPICAL INDUSTRY STANDARD ROOT BARRIER DETAIL WITH
 PLANT SELECTIONS WITH SHALLOW ROOT SYSTEMS.
  
 --ROADWAY BEATIFICATION PLAN-PROVIDE DOOR ZONES ON
 SIDEWALK FOR CLARE AVE. FOR SAFETY.
  
 --PHOTOMETRIC PLAN-TWENTY-FIVE FEET TALL STREET LIGHTS
 PROPOSED ON CLARE AVE AND ELIZABETH WILL GLARE INTO
 RESIDENTIAL UNITS, PEDESTRIAN SCALE LIGHTING IS
 RECOMMENDED.
  
 --MASTER SIGN PLAN- PLAN REQUESTS ALLOWANCE OF ONE 10
 FOOT TALL, THREE 6 FOOT TALL AND ONE 4 FOOT TALL
 SIGNAGE PER FRONTAGE. THIS NEEDS SOME REFINEMENT FOR
 HIERARCHY AND CONTEXTUAL INTEGRATION.
  
 --MASTER SIGN PLAN - UNDER SIGNAGE INTENT PLEASE ADD
 WORD ?INTERNAL? IN FRONT OF PLAZA FOR CLARITY.
  
 --MASTER SIGN PLAN- CONSISTENT WITH THE DOWNTOWN
 MASTERPLAN CODE PLEASE PROHIBIT INTERNALLY LIT BOX
 SIGNS.
  
 --MASTER SIGN PLAN- WALL AND BLADE SIGNS ARE NOT
 CONSISTENT WITH ARCHITECTURE OF STORE FRONTS.
  