Date Text
2018-05-22 13:40:43PASSED WITH CONDITIONS:
  
 1) AN INADEQUATE QUEING DISTANCE OF APPROXIMATELY 15'
 IS PROVIDED BETWEEN THE BACK OF SIDEWALK AND THE
 ROLLING GATE. SEC. 94-111. - PARKING AND LOADING
 REQUIREMENTS (P) QUEUING. NOT LESS THAT 20 LINEAR FEET
 SHALL BE PROVIDED FOR CAR QUEING, SHALL OCCUR INTERNAL
 TO THE LOT, AND SHALL NOT INTERFERE WITH PEDESTRIAN
 CIRCULATION ON A PUBLIC SIDEWALK. PROVIDE 20' OF
 STACKING DISTANCE OR LIMIT GATE OPERATION TO
 NON-BUSINESS EVENING HOURS. (REPEAT COMMENT)
  
 2) RECONSTRUCT DRIVEWAY APRON TO ONE LANE WIDTH.
  
 3) PROPOSED DRIVEWAY APRON TO HAVE LEVEL SIDEWALK AREA
 ADJACENT TO PROPERTY LINE.
  
 ERIK D. FERGUSON, PE
 CITY TRANSPORTATION ENGINEER
 561-494-1092
 [email protected]