Plan Review Notes
Plan Review Notes For Project Z17080018
Project Number Z17080018
Review Stop STORM
Sequence Number 3
Notes
Date Text
2017-12-13 14:59:49THE COOMENTS BELOW ARE FROM THE SET OF PLANS
 DISTRIBUTED THE WEEK OF 12/11/17:
  
 1. THE SITE PLAN STILL SHOWS RETENTION POND WITH BLUE
 COLOR FOR WATER. THE CONCEPTUAL ENGINEERING PLAN SHOWS
 THE FEATURE AS A DRY DETENTION AREA. THE SITE PLAN WILL
 BE CHANGED TO LABEL THE AREA AS DRY DETENTION AND THE
 BLUE COLOR CHANGED.
  
 2. THE CONCEPTUAL ENGINEERING PLAN IS NOT SHOWING THE
 LIMITS OF THE:
 A. UTILITY EASEMENT / RIGHT OF WAY EASEMENT ALONG THE
 NORTH PROPERTY LINE
 B. RIGHT OF WAY EASEMENT ALONG THE EAST PROPERTY LINE.
  
 THE ENGINEER HAS EMAILED TO SAY THE CONCEPTUAL
 ENGINEERING PLAN WILL BE RESUBMITTED WITH THE EASEMENT
 LINES SHOWN.
  
 3. A FIRE HYDRANT IS SHOWN NEAR THE NORTHEAST CORNER OF
 THE PROPERTY. THE FIRE MARSHALL HAS REQUESTED THE FIRE
 DEPARTMENT CONNECTION BE MOVED TO BE NEAR THE FIRE
 HYDRANT NEAR THE ENTRANCE ROAD AT THE SOUTHWEST CORNER
 OF THE SITE. THIS CHANGE IN FDC LOCATION WILL BE MADE
 DURING ENGINEERING PERMIT APPLICATION SUBMITTAL. THE FH
 AT THE NORTHEAST CORNER OF THE SITE WILL NOT BE NEEDED.
 THIS FH WILL NOT BE ON THE PLANS FOR ENGINEERING PERMIT
 APPLICATION.
  
 4. THE CONCEPTUAL ENGINEERING PLAN SHOWS THE EXISTING
 SANITARY SEWER GOING OUTSIDE OF THE 12' EASEMENT ALONG
 THE SOUTH PROPERTY LINE. THE SEWER SYSTEM ACTUALLY
 TURNS SOUTH BEFORE THE END OF THE EASEMENT AND CONNECTS
 TO THE OFFSITE SEWER MANHOLE SHOWN ON THE DRAWING. THIS
 CAN BE CORRECTED ON THE PLANS SUBMITTED FOR ENGINEERING
 PERMIT.
  
 5. THE CONCEPTUAL ENGINEERING PLAN SHOWS A UTILITY
 EASEMENT AROUND THE PROPOSED FIRE HYDRANT AND WATER
 METER NEAR THE NORTHEAST CORNER OF THE PROPERTY. IF THE
 EXISTING 10-UTILITY EASEMENT ALONG THE NORTH PROPERTY
 LINE IS REMAINING THEN ANOTHER UTILITY EASEMENT IS NOT
 NEEDED. THE FIRE HYDRANT AND WATER METER APPEAR TO BE
 WITHIN THE EXISTING UTILITY EASEMENT. THE ENGINEERING
 EMAILED TO SAY THE REVISED ENGINEERING PLAN DRAWING
 WILL NOT SHOW THE PROPOSED UTILITY EASEMENT AROUND THE
 WATER METER AND FIRE HYDRANT.
  
 TRACY L. WARD, P.E.
 SENIOR STORMWATER ENGINEER
 ENGINEERING SERVICES DEPARTMENT
 [email protected]
 561-494-1120
  