Plan Review Notes
Plan Review Notes For Project Z17070020
Project Number Z17070020
Review Stop FIRE
Sequence Number 1
Notes
Date Text
2017-08-01 11:16:58THE FOLLOWING COMMENTS WERE SUBMITTED BY PETER LEDUC,
 FIRE MARSHAL, BUREAU OF FIRE PREVENTION, WEST PALM
 BEACH FIRE RESCUE.
  
 THIS REVIEW CAN ONLY BE CONSIDERED PRELIMINARY AS THE
 DRAWINGS THAT WERE REVIEWED WERE NOT COMPLETE.
 ADDITIONAL COMMENTS CAN BE EXPECTED WHEN FULL DRAWINGS
 ARE SUBMITTED FOR PERMIT.
  
 THE FIRE PREVENTION BUREAU HAS NO OBJECTIONS TO THE
 PROPOSED PROJECT.
  
 1. CONSTRUCTION, DEMOLITION, AND RENOVATION TO COMPLY
 WITH NFPA 241. EXTRA ATTENTION SHALL BE GIVEN TO THE
 PERMITTING AND LOCATION OF CONSTRUCTION TRAILERS. A
 PERMIT IS REQUIRED FOR ANY CONSTRUCTION TRAILER RELATED
 TO THIS PROJECT. SEPARATION DISTANCES FROM MAIN
 STRUCTURES AS WELL AS OTHER TRAILERS SHALL BE CLOSELY
 MONITORED FOR THE REQUIREMENTS OF FIRE SPRINKLER
 PROTECTION.
  
  
 2. SITE ACCESS AND EXIT POINTS ARE TO BE CLEARLY
 IDENTIFIED AND MAINTAINED FOR EMERGENCY VEHICLES DURING
 ALL CONSTRUCTION ACTIVITIES.
  
  
 3. THE BUILDING ADDRESS SHALL BE CLEARLY VISIBLE FROM
 ALL ACCESS ROADWAYS, INCLUDING DURING CONSTRUCTION.
 ADDRESS NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND
 AND SHALL NOT BE LESS THAN SIX (6) INCHES IN HEIGHT
 WITH A ONE (1) INCH STROKE FOR ALL BUILDINGS.
  
  
 4. DURING CONSTRUCTION, TRASH AND DEBRIS IS TO BE
 REMOVED FROM THE SITE DAILY OR MORE OFTEN TO REDUCE THE
 ACCUMULATION OF POTENTIAL LIFE AND FIRE SAFETY HAZARDS.
  
  
 5. THE CONSTRUCTION OF THE BUILDING SHALL COMPLY WITH
 THE 5TH EDITION OF THE FLORIDA FIRE PREVENTION CODE,
 INCLUDING NFPA 1 & 101, AND ALL ASSOCIATED FIRE CODES.
  
  
 6. THERE ARE INDICATIONS OF EXISTING FUEL TANKS AND/OR
 FUEL LINES UNDER THE PROPOSED PARKING AREA.
  
 PLEASE ENSURE THAT THE DEPTH OF COVER MEETS THE
 REQUIREMENTS OF THE APPLICABLE CODE AS WELL FOR THE
 SIZE AND WEIGHT OF VEHILCES.
  
  
 7. 12' WIDE IS INDICATED FOR THE PARKING SPACES ON THE
 WEST SIDE.
  
 I AM NOT SURE THAT THIS DIMENSION WILL FACILTATE
 PARKING OF THE VARIOUS RESCUE VEHICLES. MANY OF THE
 EMERGENCY VEHICLES HAVE LIMITED TURNING RADIUS AND MAY
 NOT BE ABLE TO NAVIGATE INTO, OR OUT OF A PARKING SPACE
 AS PROPOSED.
  
  
 8. FOR PLAN REVIEW PURPOSES COMPLETE LIFE SAFETY PLANS
 FOR THE ER SHALL BE PROVIDED THAT ILLUSTRATE OCCUPANT
 LOADS, TRAVEL DISTANCES, COMMON PATHS OF TRAVEL,
 DEAD-END CORRIDORS, EXIT SIGNS, EMERGENCY LIGHTING,
 EXITS LEADING TO A PUBLIC WAY, FIRE EXTINGUISHER
 LOCATIONS, AND ALL FIRE SAFETY FEATURES AND EQUIPMENT.
  
 BE SURE TO INCLUDE HOW ALL EGRESS ROUTES AND REQUIRED
 EXITS WILL BE MAINTAINED DURING ALL PHASES OF
 CONSTRUCTION.
  
  
  
 9. THE BUREAU'S APPROVAL OF THIS SUBMITTED PROJECT DOES
 NOT CONSTITUTE IT'S FINAL REVIEW OR APPROVAL.
  
  
  
 10. THE BUREAU SHALL REVIEW ALL SUBMITTED BUILDING
 PLANS AT THE APPROPRIATE TIME AND IN ACCORDANCE WITH
 THE REQUIREMENTS OF ALL APPLICABLE CODES AND STANDARDS.
  
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  
  
  