2017-12-11 11:19:11FROM: RAY CARANCI, LANDSCAPE PLANNER 561-822-1462
 MEMO TO FILE
 PROJECT: PALM BEACH GARAGE Z17070013
 DECEMBER 7, 2017
 I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND
 PROVIDE THE FOLLOWING COMMENTS:
  
 1. NOT SATISFIED. THE APPROVED LANDSCAPE PLAN SHOWS THE
 PREVIOUSLY APPROVED TREES AND PALMS ON SITE. PLEASE
 ACCOUNT FOR ALL EXISTING TREES AND PALMS THAT MATCH THE
 APPROVED PLAN, AND LABEL THEM ON THE PROPOSED LANDSCAPE
 PLAN BY SPECIES.
  
 IDENTIFY ALL EXISTING TREES WITH SPECIES TAGS AND
 INCLUDE IN THE PLANT LIST AS PART OF THE PROPOSED
 LANDSCAPE PLAN.
  
 2. SATISFIED. PLEASE PROVIDE A TREE DISPOSITION LIST
 SHOWING TREES AND PALMS TO REMAIN, BE RELOCATED OR
 REMOVED.
  
 3. SATISFIED. PLEASE UPDATE THE OVERALL LANDSCAPE
 REQUIREMENT CHART TO CURRENT CODE REQUIREMENTS FOR
 SHADE TREES AND FLOWERING TREES FOR THE SITE.
  
 4. NOT SATISFIED. THE LANDSCAPE BUFFER TREE REQUIREMENT
 CALCULATIONS ARE NOT MET ON THE PLAN FOR THE EAST
 BUFFER. PALMS MAY ONLY BE SUBSTITUTED AT A 3 TO 1 RATIO
 FOR REQUIRED TREES.
  
 DRIVEWAY WIDTHS ARE TO BE COUNTED TOWARD THE BUFFER
 LENGTH AND REQUIRED BUFFER TREE COUNT CALCULATION AS
 MEASURED ALONG THE CENTER LINE OF THE BUFFER. PLEASE
 REVISE. SEE SECTION 94-443(B)(5).
  
 5. PARTIALLY SATISFIED. PLEASE PROVIDE AN UPDATED CHART
 SHOWING COMPLIANCE WITH FLORIDA FRIENDLY LANDSCAPING
 PER SECTION 94-442 (G). THIS INCLUDES SHOWING DROUGHT
 TOLERANCE LEVEL AND NATIVE SPECIES ON THE PLANT LIST
 AND PROVIDING THE REQUIRED 40 POINTS.
  
 TREE AND SHRUB CATEGORIES MAY NOT BE COUNTED TWICE FOR
 DROUGHT TOLERANT AND NATIVE OPTIONS AND CANNOT ADD UP
 TO MORE THAN 100%. 51% AND 25-50% ARE MAXIMUM.
  
 6. SATISFIED. PLEASE SHOW LOCATIONS OF ROOT BARRIERS TO
 PROTECT INFRASTRUCTURE AND TREES FROM CONFLICTS. THIS
 INCLUDES WATER, SEWER, DRAINAGE, SIDEWALKS AND CURBS,
 AND ANY FIELD STRUCTURES THAT COULD BE IMPACTED BY TREE
 ROOTS.
  
 7. SATISFIED. PLEASE PROVIDE SCREENING FOR ALL GROUND
 MOUNTED EQUIPMENT AND UTILITIES. WATER BACKFLOW VALVES
 AND FPL TRANSFORMERS MUST HAVE SCREENING HEDGES.
  
 8. SATISFIED. TREE HEIGHTS NEED TO MEET THE REQUIRED 12
 FEET HEIGHT SPECIFIED IN SECTION 94-445(4).
  
 9. PARTIALLY SATISFIED. PARKING LOT LANDSCAPE AREAS
 MUST MEET THE REQUIREMENTS OF SECTION 94-443(C)(3) AND
 (4). PLEASE SHOW ALL CALCULATIONS AND PROVIDE A DIAGRAM
 SHOWING THE AREAS COUNTED TOWARD THIS REQUIREMENT.
  
 PLEASE PROVIDE CALCULATIONS FOR SECTION 94-443(C)(4).
  
 10. SATISFIED. PLEASE PROVIDE THE LOCATIONS OF LIGHTING
 ON THE LANDSCAPE PLAN.
  
 11. SATISFIED. PLEASE PROVIDE CALCULATIONS FOR THE
 REQUIRED BUILDING PERIMETER PLANTING OF 30 PERCENT FOR
 THE EXISTING BUILDING AND PROPOSED BUILDING PER SECTION
 94-444(E)(1).
  
 12. SATISFIED. PALM IN THE TERMINAL LANDSCAPE ISLAND AT
 THE NORTHEAST CORNER OF THE PROPERTY DOES NOT MEET THE
 SHADE TREE REQUIREMENT OR THE BUFFER TREE REQUIREMENT.
 ADDITIONAL COMMENTS 12/7/17:
 13. PLEASE CHANGE TO LARGER TREE SPECIES IN THE BUFFER
 TO THE SOUTH OF THE PROPOSED BUILDING TO PROVIDE MORE
 SUBSTANTIAL BUFFERING RATHER THAN THE SMALL TREE
 SPECIES PROPOSED.
  
 14. PLEASE PROVIDE THE WEST BUFFER IN THE BUFFER
 CALCULATION CHART, AND PROVIDE THE REQUIRED TREES OR
 PALMS FOR BUFFERING OF THE PROPOSED BUILDING.
  
 15. PLEASE PROVIDE ONLY ONE PLANT LIST FOR THE ENTIRE
 SITE. PLAN MAY HAVE ENLARGED DETAIL OF THE EAST
 LANDSCAPE AREA, BUT PLANT LIST MUST BE CONSOLIDATED.
  
 16. PLEASE PROVIDE THE REQUIRED TREE IN THE TERMINAL
 LANDSCAPE ISLAND AT THE NORTHEAST CORNER OF THE
 PROPOSED BUILDING NEXT TO THE ADA PARKING SPACE.
  
 CONDITIONS OF APPROVAL
 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON
 THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE
 SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT
 SERVICES DEPARTMENT, PLANNING DIVISION.
  