2017-07-07 16:59:30CITY OF WEST PALM BEACH
 ENGINEERING SERVICES DEPARTMENT
  
 PROJECT NAME: PALM BEACH TOUR & TRANSPORTATION - 1422
 OKEECHOBEE RD. - Z17060017
  
 RESPONSE: PASSED WITH CONDITION
  
 DATE: JULY 11, 2017
  
 THIS IS AN INITIAL LEVEL REVIEW. CONSTRUCTION LEVEL
 DETAILS, DESIGN CALCULATIONS, AND THE POLLUTION
 PREVENTION PLAN WILL BE REVIEWED AS PART OF THE
 ENGINEERING DEVELOPMENT APPROVAL AND BUILDING PERMIT
 APPLICATION PROCESSES.
  
 THE FOLLOWING GENERAL COMMENTS MUST BE ADDRESSED PRIOR
 TO ISSUANCE OF CONSTRUCTION AUTHORIZATION INCLUDING
 BUILDING PERMITS AND ENGINEERING DEVELOPMENT APPROVAL:
  
 1. AN ENGINEERING DEVELOPMENT APPROVAL APPLICATION WILL
 BE REQUIRED FROM THE ENGINEERING SERVICES DEPARTMENT.
 THE ENGINEERING DEVELOPMENT APPROVAL APPLICATION FORMS
 CAN BE DOWNLOADED FROM THE FOLLOWING WEBSITE LINK:
  
 HTTP://WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS/FOR
 MS,-PERMITS-APPLICATIONS
  
 2. PLEASE SUBMIT THE LATEST VERSION OF THE "AUTO-CALC
 CERTIFIED COST ESTIMATE FORM" FOR SUBMISSION TO CITY OF
 WEST PALM BEACH PUBLIC WORKS DEPARTMENT FOR ADDITIONAL
 WORK PROPOSED. THIS FORM CAN BE DOWNLOADED FROM THE
 FOLLOWING LINK:
  
 HTTP://WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS/FOR
 MS,-PERMITS-APPLICATIONS
  
 3. WHAT IS THE PLAN FOR WATER AND SANITARY SEWER
 SERVICE FOR THE PROPOSED WASH AREA/BAY (AS SHOWN IN THE
 'BUILDING FLOOR PLANS - 3.1')? SUBMIT UTILITY PLAN FOR
 WATER AND SEWER WITH THE FINAL PLANS;
  
 4. WHAT IS THE PLAN FOR FIRE PROTECTION FOR THE
 PROPOSED "BUILDING B"? SHOW PROPOSED FIRE LINE AND
 BACKFLOW PREVENTER, METER ASSEMBLY ETC. IN THE UTILITY
 PLAN DURING FINAL PLANS SUBMITTALS;
  
 5. SHOW ON THE FINAL PLANS ADA ACCESSIBLE RAMP ON THE
 SIDEWALK FOR THE PROPOSED DRIVE/ACCESS AND ADD A DETAIL
 FOR THE SPECIFIC RAMP TYPE;
  
 6. EXISTING WATER SERVICE CONNECTIONS/WATER METERS
 SERVING THE PROPERTY, IF NOT USED, ARE TO BE CUT AND
 CAPPED AT THE MAIN. DE-ACTIVATED/INACTIVE PIPELINES
 LARGER THAN 2" DIAMETER WILL BE REMOVED. PLEASE LABEL
 PIPE SIZE AND MATERIAL AND ADD NOTES TO THE UTILITY
 PLANS ACCORDINGLY;
  
  
  