2017-05-05 17:10:53CITY OF WEST PALM BEACH
 ENGINEERING SERVICES DEPARTMENT
  
 DATE: 05/05/2017
  
 Z17040019: 2331 NORTHWOOD UNIVERSITY DR. - KEISER
 UNIVERSITY ATHLETIC FIELD ADDITION (PB CASE NO. 1069U)
  
 THIS IS AN INITIAL LEVEL REVIEW. CONSTRUCTION LEVEL
 DETAILS, DESIGN CALCULATIONS, AND THE POLLUTION
 PREVENTION PLAN WILL BE REVIEWED AS PART OF THE
 ENGINEERING DEVELOPMENT APPROVAL AND BUILDING PERMIT
 APPLICATION PROCESSES.
  
 FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO SITE PLAN
 APPROVAL:
  
 1. PLEASE SUBMIT ENGINEERING PLANS SHOWING HOW THE
 ATHLETIC BUILDING WILL BE SERVED FOR WATER, SEWER AND
 FIRE PROTECTION. ON THE REVISED PLANS SHOW ALL EXISTING
 UTILITIES IN THE VICINITY OF THE SITE AND LABEL THEIR
 SIZE AND MATERIALS.
  
 2. PLEASE SUBMIT ESTIMATES FOR THE PEAK POTABLE WATER
 AND FIRE DEMAND; AND SANITARY SEWER FLOW FOR THE
 PROPOSED ATHLETIC BUILDING.
  
 3. SHOW ON THE PLANS ANY EXISTING FIRE HYDRANT CLOSEST
 TO THE BUILDING AND ITS DISTANCE. ALL PROPOSED FIRE
 DEPARTMENT CONNECTIONS SHALL BE WITHIN 150 FEET OF A
 FIRE HYDRANT AND SHALL BE WITHIN AN EASEMENT WITHIN THE
 PROPERTY.
  
 4. PLEASE SUBMIT ESTIMATES FOR THE SOLID WASTE
 COLLECTION YARDAGE AT THIS STAGE. AS PART OF THE FINAL
 DESIGN, THIS SOLID WASTE ESTIMATE WILL NEED TO BE
 VERIFIED TO VALIDATE APPROPRIATE NUMBER AND SIZE OF
 DUMPSTERS/GARBAGE RECEPTACLES.
  
 5. FOR SANITATION/GARBAGE COLLECTION CONTACT THE CITY'S
 PUBLIC WORKS DEPARTMENT. SUBMIT A LETTER OF APPROVAL
 FOR SANITATION PLANS, SIZE OF GARBAGE BINS AND LOCATION
 OF THE PROPOSED DUMPSTER ENCLOSURE FROM PETER BIENIEK,
 PUBLIC WORKS DIRECTOR PRIOR TO SITE PLAN APPROVAL.
 PLEASE INCLUDE THE CITY OF WEST PALM BEACH STANDARD
 DETAIL FOR THE DUMPSTER ENCLOSURE ON THE PLANS. MINIMUM
 DIMENSIONAL (E.G. THE GATE WIDTH MUST BE A MINIMUM OF
 12.5 FEET) REQUIREMENTS FOR THE ENCLOSURE ARE LISTED IN
 CODE OF ORDINANCES, SECTION 94-444(B) OF THE CODE OF
 ORDINANCES. CITY STANDARD DETAIL GC-8 MAY BE DOWNLOADED
 AT:
  
 HTTP://WPB.ORG/ENGINEERING/ENGINEERING-SERVICES/ENGINEE
 RING-STANDARDS/
  
 6. PROVIDE AN AUTOTURN ANALYSIS DEMONSTRATING THE SOLID
 WASTE COLLECTION VEHICLE CAN ACCESS AND MANEUVER WITHIN
 THE SITE/PROPOSED DEVELOPMENT.
 AFTER THE SITE PLAN IS APPROVED, IN THE NEXT PHASE, THE
 FOLLOWING GENERAL COMMENTS MUST BE ADDRESSED PRIOR TO
 ISSUANCE OF CONSTRUCTION AUTHORIZATION INCLUDING
 BUILDING PERMITS AND ENGINEERING DEVELOPMENT APPROVAL:
  
 7. AN ENGINEERING DEVELOPMENT APPROVAL APPLICATION WILL
 BE REQUIRED FROM THE ENGINEERING SERVICES DEPARTMENT.
 THE ENGINEERING DEVELOPMENT APPROVAL APPLICATION FORMS
 CAN BE DOWNLOADED FROM THE FOLLOWING WEBSITE LINK:
  
 HTTP://WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS/FOR
 MS,-PERMITS-APPLICATIONS
  
 8. PLEASE SUBMIT THE LATEST VERSION OF THE 'AUTO-CALC
 CERTIFIED COST ESTIMATE FORM' FOR SUBMISSION TO CITY OF
 WEST PALM BEACH PUBLIC WORKS DEPARTMENT FOR ADDITIONAL
 WORK PROPOSED. THIS FORM CAN BE DOWNLOADED FROM THE
 FOLLOWING LINK:
  
 HTTP://WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS/FOR
 MS,-PERMITS-APPLICATIONS
  
 9. FIRE HYDRANT FLOW TEST DATA FROM THE CLOSEST
 EXISTING FIRE HYDRANT WILL BE REQUIRED PART OF THE PLAN
 SUBMITTAL;
  
 10. IN THE FINAL WATER AND SEWER PLANS, INCLUDE A NOTE
 THAT: AS OF DECEMBER 20, 2015 THE CITY OF WEST PALM
 BEACH CROSS-CONNECTION CONTROL MANUAL HAS BEEN REVISED,
 MAKING KNOWN THAT "ALL BACKFLOW DEVICES MUST BE LEAD
 FREE." FOR MORE INFORMATION REFER TO THE LINK BELOW:
  
 HTTP://WPB.ORG/DEPARTMENTS/PUBLIC-UTILITIES/FORMS-PUBLI
 CATIONS/BACKFLOW-CROSS-CONNECTION-CONTROL-MANUAL
  
 MOSTAQUE KHAN, P.E.
 LAND DEVELOPMENT ENGINEER
 [email protected]
 561-494-1124 (OFFICE)
  
  Print