| Date |
Text |
| 2017-07-11 11:52:03 | VARIANCE REQUESTED: |
| | |
| | 1.) A VARIANCE FROM ZLDR S. 94-209(2)(J)(1)(M), WHICH |
| | REQUIRES A MINIMUM DWELLING UNIT SIZE OF 550 SQ. FT. |
| | AND A CUMULATIVE AVERAGE OF 800 SQ. FT. FOR ALL |
| | DWELLING UNITS, TO ALLOW FOR A MINIMUM DWELLING UNIT |
| | SIZE OF 502 SQ. FT. AND A CUMULATIVE AVERAGE OF 680 SQ. |
| | FT., SHALL BE APPROVED BY THE ZONING BOARD OF APPEALS |
| | (ZBA) PRIOR TO THE APPROVAL OF THE SITE PLAN. |
| | |
| | 2.) A VARIANCE FROM ZLDR S.94-215(H)(2), WHICH REQUIRES |
| | A MINIMUM BUILDING SETBACK OF 10 FT., TO ALLOW A 0 FT. |
| | SETBACK ON 27TH STREET (SECONDARY A), MUST BE GRANTED |
| | BY THE ZBA PRIOR TO THE APPROVAL OF THE SITE PLAN. |
| | |
| | |
| | GENERAL COMMENTS: |
| | |
| | 1.) THE SITE PLAN MUST BE TECHNICALLY SOUND PRIOR TO |
| | SCHEDULING FOR THE ZONING BOARD OF APPEALS (ZBA). THE |
| | REVISED SITE PLAN IS FURTHER OUT OF COMPLIANCE WITH THE |
| | ZONING AND LAND DEVELOPMENT REGULATIONS. THESE ISSUES |
| | MUST BE ADDRESSED AND/OR ADDITIONAL VARIANCES/WAIVERS |
| | WILL NEED TO BE REQUESTED AS PART OF THE ZBA |
| | APPLICATION. |
| | |
| | 2.) RESPONSES TO THE PPRC'S COMMENTS SHALL BE PROVIDED |
| | WITH THE RESUBMITTAL. |
| | |
| | 3.) JUSTIFICATION LETTER MUST CLEARLY SPECIFY THE |
| | PROPOSED USE FOR THE PROPERTY (I.E. WILL THE RESIDENTS |
| | BE UNDER THE SUPERVISION OF DOCTORS AND/OR NURSES? WHAT |
| | ARE THE OFFICE ON THE GROUND FLOOR FOR? ARE THESE |
| | OFFICES OPEN TO THE PUBLIC, ETC.). THE GROUND LEASE |
| | AGREEMENT PROVIDED WITH THE ORIGINAL SUBMITTAL |
| | INDICATES THAT THE PROJECT WILL ALSO PROVIDE "MENTAL |
| | HEALTH SERVICES TO RESIDENTS." STAFF MUST DETERMINE IF |
| | THIS PROPOSED PROJECT IS A SINGLE USE OR A MIXED USE |
| | PROJECT. |
| | |
| | 4.) PLEASE NOTE THAT IF THE OFFICES ON THE FIRST FLOOR |
| | WILL BE USED TO PROVIDE TREATMENT FOR THE RESIDENTS OF |
| | THE APARTMENT ONLY, THEN THE USE WILL BE CONSIDERED A |
| | GROUP HOME AND WILL REQUIRE A CLASS B SPECIAL USE |
| | PERMIT; HOWEVER, IF THE OFFICES ARE OPEN TO THE GENERAL |
| | PUBLIC, THEN THE USE WILL BE CONSIDERED A MIX USE |
| | PROJECT. THEREFORE, IT IS IMPORTANT TO CLARIFY THE |
| | SPECIFIC USE. |
| | |
| | 5.) A RE-PLAT OF THE PROPERTY IS REQUIRED. |
| | |
| | 6.) PROVIDE A LETTER FROM THE PALM BEACH COUNTY TRAFFIC |
| | DIVISION STATING THAT THE PROJECT COMPLIES WITH THE |
| | TRAFFIC PERFORMANCE STANDARDS (TPS) OF THE COUNTY. |
| | |
| | 7.) PROVIDE A LETTER FROM THE SCHOOL DISTRICT OF PALM |
| | BEACH COUNTY INDICATING THAT THE PROJECT MEETS SCHOOL |
| | CAPACITY STANDARDS. |
| | |
| | |
| | SITE PLAN/ARCHITECTURAL COMMENTS: |
| | |
| | 1.) SCALE SEEMS TO BE INCORRECT; THE DIMENSIONS ARE |
| | INACCURATE WHEN MEASURED. PLEASE ADDRESS. |
| | |
| | 2.) PROVIDE INFORMATION ON THE TOTAL AMOUNT OF OFFICE |
| | SQUARE FOOTAGE IN THE SITE DATA TABULAR ON SHEET G-2. |
| | THE AMOUNT OF OFFICE SQUARE FOOTAGE WILL DETERMINE THE |
| | REQUIREMENT FOR A LOADING ZONE WHICH MUST BE CLEARLY |
| | PROVIDED IN THE DATA. |
| | |
| | 3.) PLEASE MAKE THE FOLLOWING CORRECTIONS IN THE SITE |
| | DATA TABULAR ON SHEET G-2: CLEARLY STATE THE NUMBER OF |
| | DWELLING UNITS PROPOSED FOR THE PROJECT (36 UNITS); |
| | CLEARLY STATE THE SQUARE FOOTAGE OF THE OFFICE |
| | COMPONENT; CHECK ACCURACY OF THE NET LOT AREA AND THE |
| | PROVIDED MINIMUM LOT AREA. THE NUMBERS SHOULD BE |
| | CONSISTENT WITH THE INFORMATION PROVIDED IN THE |
| | SURVEY/PLAT; CHECK THE BUILDING HEIGHT. THE MAXIMUM |
| | HEIGHT OF THE BUILDING SHALL BE MEASURED AT THE TALLEST |
| | POINT OF THE BUILDING. THE HEIGHT OF 42'-8" IS NOT |
| | ACCURATE; THE PARCEL WIDTH PROVIDED IS 92.67 FT. (NOT |
| | 100 FT.); THE PARCEL DEPTH PROVIDED IS 312 FT. (NOT 300 |
| | FT.); CHECK INTERIOR SIDE SETBACK PROVIDED. THE |
| | INTERIOR SIDE SETBACK DOES NOT SEEM TO BE 20'-8"; |
| | PROVIDE IMPERVIOUS SURFACE REQUIREMENTS AND |
| | CALCULATIONS; CHECK PERVIOUS SURFACE CALCULATIONS; |
| | CLEARLY PROVIDE THE PARKING REQUIREMENTS. PARKING |
| | REQUIREMENT FOR THE OFFICE USE MUST ALSO BE INCLUDED IN |
| | THE CALCULATIONS; PROVIDE BICYCLE PARKING CALCULATIONS. |
| | |
| | 4.) EXTEND THE WIDTH OF THE CROSSWALK ON POINSETTIA |
| | AVENUE SO THAT THE CROSSWALK LINES UP WITH THE |
| | SIDEWALK. |
| | |
| | 5.) PER ZLDR S.94-209 2.(D)(2), THE CROSSWALKS ON BOTH |
| | 27TH STREET AND POINSETTIA AVENUE SHALL BE LIGHTED FOR |
| | SAFETY AND SHALL REQUIRE A CHANGE IN TACTILE SURFACE |
| | TEXTURE. PLEASE DEMONSTRATE COMPLIANCE AND PROVIDE |
| | INFORMATION ON THE SURFACE TEXTURE OF THE CROSSWALK. |
| | |
| | 6.) THE STRIPING DETAILS IN SHEET A-0.2 SHALL COMPLY |
| | WITH THE DIMENSIONS PROVIDED IN THE STALL PAINTING |
| | DETAIL IN ZLDR S.94-485(J). THE DETAIL PROVIDED IN |
| | SHEET A-0.2 INDICATES THAT THE STRIPING IS WIDER THAN |
| | NECESSARY AND THE EXCESS SPACE COULD BE UTILIZED TO |
| | PROVIDE ADDITIONAL GREEN SPACE FOR THE TERMINAL |
| | ISLANDS. |
| | |
| | 7.) WHEEL STOPS CANNOT BE UTILIZED FOR COMPACT PARKING |
| | STALLS THAT ARE ONLY 16 FT. DEEP. CONSIDER A 2 FT. CURB |
| | OVERHANG INTO THE LANDSCAPE AREA OR PROVIDE PARKING |
| | STALLS THAT ARE 18 FT. DEEP WITH A WHEEL STOP. |
| | |
| | 8.) ONLY 25 PERCENT OF THE TOTAL NUMBER OF PARKING |
| | SPACES MAY BE DESIGNATED FOR SMALL CAR USE (COMPACT |
| | PARKING STALLS). [ZLDR S.94-485(N)(1)] |
| | |
| | 9.) EACH ROW OF PARKING SPACES SHALL BE TERMINATED BY |
| | LANDSCAPED ISLANDS OF NOT LESS THAN 5 FT. IN WIDTH |
| | (FROM THE INSIDE OF THE CURB). THE PARKING AREA DOES |
| | NOT MEET THIS MINIMUM REQUIREMENT. PLEASE ADDRESS. |
| | [ZLDR S.94-443(C)(3)] |
| | |
| | 10.) ONE INTERIOR LANDSCAPE ISLAND SHALL BE REQUIRED |
| | FOR EVERY TEN (10) PARKING SPACES IN A ROW. INTERIOR |
| | LANDSCAPE ISLANDS SHALL BE AT LEAST 5 FT. WIDE MEASURED |
| | FROM THE INSIDE OF THE CURB AND SHALL CONTAIN AT LEAST |
| | ONE (1) SHADE OR FLOWERING TREE PER ROW OF PARKING. THE |
| | PARKING AREA DOES NOT MEET THIS MINIMUM REQUIREMENT. |
| | PLEASE ADDRESS. [ZLDR S.94-443(C)(3)] |
| | |
| | 11.) THE DETAILS ON SHEET A-0.2 INDICATE THE USE OF A |
| | HANDICAP SIGN ON A POST; HOWEVER, IT IS NOT CLEAR TO |
| | WHERE THE SIGN WILL BE PLACED. PLEASE SHOW IN THE SITE |
| | PLAN WHERE THE SIGN WILL BE LOCATED. |
| | |
| | 12.) BICYCLE PARKING IS REQUIRED PURSUANT TO ZLDR |
| | S.94-209 2.(N). PLEASE ILLUSTRATE THE LOCATION OF THE |
| | BICYCLE PARKING. BICYCLE PARKING IS REQUIRED FOR THE |
| | RESIDENTIAL AND OFFICE COMPONENT FOR THE PROJECT. |
| | |
| | 13.) ON-STREET PARKING DIRECTLY AND WHOLLY ABUTTING THE |
| | SUBJECT PROPERTY MAY BE COUNTED TOWARDS THE PARKING |
| | REQUIREMENT. THIS SHOULD BE CONSIDERED SINCE THE DESIGN |
| | OF THE PARKING AREA IS INADEQUATE AND FAILS TO MEET THE |
| | MINIMUM REQUIREMENTS OF THE ZLDRS (I.E. ADEQUATE BACK |
| | OUT FOR VEHICLES, INSUFFICIENT SPACE PROVIDED TO OPEN |
| | DOORS, REQUIRED TERMINAL/LANDSCAPE ISLANDS, ETC.). |
| | [ZLDR S.94-485(B)(2)] |
| | |
| | 14.) PLEASE PROVIDE DIMENSION AT THE ENTRANCE/EXIT ON |
| | 27TH STREET. THE ENTRANCE/EXIT SHALL NOT EXCEED 24 FT. |
| | MAXIMUM. [ZLDR S.94-209 2.(E)(2)] |
| | |
| | 15.) THE REQUIRED MINIMUM 5 FT. WIDE LANDSCAPE BUFFER |
| | STRIP ALONG THE SIDE AND REAR PROPERTY LINES SHALL BE |
| | MEASURED FROM THE INSIDE OF THE CURB (NOT OUTSIDE). THE |
| | BUFFER STRIP CURRENTLY DOES NOT MEET THIS MINIMUM |
| | REQUIREMENT. PLEASE ADDRESS. [ZLDR S.94-209 2.(F)] |
| | |
| | 16.) STREET TREES ARE REQUIRED AND SHALL BE SPACED AT A |
| | MAXIMUM OF 30 FT. ON CENTER. [ZLDR S.94-209 2.(F)(2)] |
| | |
| | 17.) A LANDSCAPE PLAN WAS NOT INCLUDED AS PART OF THE |
| | SUBMITTAL; THEREFORE, A FORMAL REVIEW OF THE LANDSCAPE |
| | REQUIREMENTS COULD NOT BE COMPLETED. |
| | |
| | 18.) WILL THERE BE ANY SITE LIGHTING? IF SO, PLEASE |
| | PROVIDE A PHOTOMETRIC PLAN. |
| | |
| | 19.) LIGHT POLES SHALL COMPLY WITH THE FOLLOWING |
| | STANDARDS PER ZLDR S.94-209 2.(I): LIGHT POLE FIXTURES |
| | SHALL NOT EXCEED AN OVERALL HEIGHT OF 17.5 FT. ABOVE |
| | GRADE; NO COBRA HEAD LIGHTS ARE PERMITTED; ALL LIGHTING |
| | SHALL BE LED OR LIGHT-EMITTING DIODE; ALL LIGHTING |
| | SHALL BE WEATHER AND VANDAL RESISTANT (I.E. RESISTANT |
| | TO GRAFFITI, SHATTERING, ETC.) |
| | |
| | 20.) THE COLONNADE SHALL BE GUTTERED, AND DRAINAGE |
| | SHALL BE DEPOSITED ON SITE. [ZLDR S.94-209 2.(J)] |
| | |
| | 21.) IF THE GROUND FLOOR OFFICES ARE CONSIDERED AN |
| | ACTIVE USE, THEN THESE OFFICES SHALL COMPLY WITH THE |
| | ACTIVE USE STANDARDS OF ZLDR S.94-209 2.(J), INCLUDING, |
| | BUT NOT LIMITED TO: MUST HAVE A TRANSPARENT CLEAR |
| | GLAZED AREA OF NOT LESS THAN 70 PERCENT OF THE FACADE |
| | AREA. PROVIDE CALCULATIONS; GROUND FLOOR WINDOW SILLS |
| | SHALL BE PLACED AT A MAXIMUM HEIGHT OF 24 INCHES ABOVE |
| | GRADE. PROVIDE ILLUSTRATIONS WITH DIMENSIONS. |
| | |
| | 22.) ACTIVE USE LINER MUST HAVE A MINIMUM DEPTH OF 20 |
| | FT. THE DEPTH OF THE CURRENT ACTIVE LINER USE SEEMS TO |
| | FALL SHORT OF THIS MINIMUM REQUIREMENT. ALSO, PLEASE |
| | PROVIDE DIMENSIONS. [ZLDR S.94-209 2.(J)] |
| | |
| | 23.) PROVIDE DIMENSIONS TO DEMONSTRATE THAT THE |
| | COLONNADE COLUMN SPACING, WINDOWS AND DOORS ARE |
| | PROPORTIONED SUCH THAT THE HEIGHT OF EACH OPENING IS |
| | GREATER THAN ITS WIDTH. [ZLDR S.94-209 2.(J)(1)] |
| | |
| | 24.) ARE THE INDIVIDUAL UNITS EQUIPPED WITH KITCHENS |
| | AND BATHROOMS? IF SO, PLEASE ILLUSTRATE IN THE FLOOR |
| | PLAN. |
| | |
| | 25.) HOW DO THE RESIDENTS GET ACCESS TO THE GYM? THERE |
| | DOES NOT SEEM TO BE AN OPENING TO THE GYM ROOM. PLEASE |
| | ADDRESS. |
| | |
| | 26.) THE SITE PLAN REFERENCES A 10 FT. WIDE ARCADE; |
| | HOWEVER, THE DESIGN INDICATES THAT IT IS A COLONNADE. |
| | PLEASE CORRECT. |
| | |
| | 27.) COLONNADE COLUMN SPACING, WINDOWS AND DOORS SHALL |
| | BE PROPORTIONED SUCH THAT THE HEIGHT OF EACH OPENING IS |
| | GREATER THAN ITS WIDTH. [ZLDR S.94-209 2.(J)] |
| | |
| | 28.) THE COLONNADE SHALL HAVE A MINIMUM 10 FT. VERTICAL |
| | CLEARANCE FROM THE SIDEWALK. [ZLDR S.94-209 2.(J)] |
| | |
| | 29.) THE BALCONIES SHALL NOT PROJECT MORE THAN 4 FT. OF |
| | THE BACK OF CURB. PLEASE PROVIDE DIMENSIONS TO |
| | DEMONSTRATE COMPLIANCE. [ZLDR S.94-209 2.(J)(3)] |
| | |
| | 30.) THE REQUIRED BUILDING FRONTAGE ALONG POINSETTIA |
| | AVENUE AND 27TH STREET IS 80 PERCENT. PLEASE PROVIDE |
| | CALCULATIONS TO DEMONSTRATE COMPLIANCE. [ZLDR |
| | S.94-215(H)] |
| | |
| | 31.) THE COLONNADE SHALL MEET THE BUILDING SETBACK |
| | REQUIREMENT IF THE PORTION OF THE COLONNADE IS TO BE |
| | CONSIDERED PART OF THE BUILDING FRONTAGE, AND SHALL |
| | CONTAIN ACTIVE USE. [ZLDR S.94-215(O)] |
| | |
| | 32.) THE MINIMUM OPEN SPACE REQUIREMENT FOR THE PROJECT |
| | IS 10 PERCENT. PLEASE PROVIDE CALCULATIONS TO |
| | DEMONSTRATE COMPLIANCE. [ZLDR S.94-215(J)] |
| | |
| | |
| | INSTRUCTIONS FOR RESUBMITTAL: |
| | |
| | * PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN |
| | WRITTEN FORMAT. |
| | |
| | * WHEN RESUBMITTING, PLEASE PROVIDE A MINIMUM OF SIX |
| | (6) PAPER COPIES, ONE (1) REDUCED COPY IN 8.5 INCHES X |
| | 11 INCHES AND ONE (1) SET IN 11 INCHES X 17 INCHES, AND |
| | AN ELECTRONIC COPY OF ALL PLANS. PLEASE NOTE THAT |
| | CHANGES ON THE RESUBMITTED PLANS MAY RESULT IN |
| | ADDITIONAL COMMENTS. |
| | |
| | * PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1) |
| | RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY-ISSUED |
| | COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE |
| | APPLICANT WILL BE ASSESSED A RESUBMITTAL FEE. SUCH FEE |
| | WILL BE 20 PERCENT OF THE ORIGINAL APPLICATION FEE. |
| | |
| | * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE |
| | QUESTIONS. |
| | |
| | |
| |
Print |