| Date |
Text |
| 2017-04-12 10:10:32 | THIS IS A CONCEPTUAL LEVEL REVIEW. CONSTRUCTION LEVEL |
| | DETAILS, DESIGN CALCULATIONS AND THE POLLUTION |
| | PREVENTION PLAN WILL BE REVIEWED AS PART OF THE |
| | ENGINEERING DEVELOPMENT APPROVAL AND BUILDING PERMIT |
| | APPLICATION PROCESSES. THE ENGINEERING DEVELOPMENT |
| | APPROVAL APPLICATION FORMS CAN BE DOWNLOADED AT HTTP:// |
| | WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS/FORMS,-PER |
| | MITS-APPLICATIONS |
| | |
| | THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO SITE |
| | PLAN APPROVAL: |
| | 1. NO ENGINEERING PLANS WERE SUBMITTED FOR REVIEW. |
| | |
| | 2. PRELIMINARY, UPDATED FEMA FLOOD INSURANCE MAPS ARE |
| | AVAILABLE AT |
| | HTTP://MAPS.CO.PALM-BEACH.FL.US/GIS/FLOODZONES.ASPX?. |
| | PLEASE REVIEW THE MAPS AND VERIFY THAT THE NEW MAPS |
| | WILL NOT IMPACT THE PROPOSED PROJECT. |
| | |
| | 3. THE FREEBOARD REQUIREMENT FOR STRUCTURES IN A |
| | SPECIAL FLOOD HAZARD AREA IS ONE FOOT ABOVE BASE FLOOD |
| | ELEVATION. |
| | |
| | 4. LOCATION OF WEST PROPERTY LINE SHOWN ON SITE PLAN |
| | (I.E. 32' 7" FROM CENTERLINE OF POINSETTIA AVE) DOES |
| | NOT AGREE WITH THE PROPOSED LOCATION OF THE PROPERTY |
| | LINE SHOWN ON THE PROPOSED PLAT (I.E. 49' FROM |
| | CENTERLINE OF POINSETTIA AVE) |
| | |
| | 5. LOCATION OF SOUTH PROPERTY LINE SHOWN ON SITE PLAN |
| | (I.E. 34' 6" FROM CENTERLINE OF 27TH ST.) DOES NOT |
| | AGREE WITH THE PROPOSED LOCATION OF THE PROPERTY LINE |
| | SHOWN ON THE PROPOSED PLAT (I.E. 22' 4" FROM CENTERLINE |
| | OF 27TH ST.) |
| | |
| | 6. DRAINAGE DESIGN TO MEET SFWMD CRITERIA FOR WATER |
| | QUALITY AND STORMWATER RUNOFF FROM THE SITE. |
| | |
| | 7. CITY'S VERTICAL DATUM IS THE NATIONAL GEODETIC |
| | VERITCAL DATUM OF 1929. USE OF ANY OTHER VERTICAL DATUM |
| | WILL REQUIRE APPROVAL OF THE ENGINEERING SERVICES |
| | DEPARTMENT AND THE RELATIONSHIP BETWEEN THE DATUM USED |
| | AND NGVD 1929 SHOWN ON THE PLANS. |
| | |
| | 8. PUBLIC SIDEWALKS OUTSIDE THE RIGHT-OF-WAY MAY |
| | REQUIRE THE LAND OWNER PROVIDE AN EASEMENT TO THE CITY. |
| | |
| | THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO |
| | ISSUANCE OF CONSTRUCTION AUTHORIZATION INCLUDING |
| | BUILDING PERMITS AND ENGINEERING DEVELOPMENT APPROVAL. |
| | |
| | 1. AN ENGINEERING DEVELOPMENT APPROVAL APPLICATION WILL |
| | BE REQUIRED FROM THE ENGINEERING SERVICES DEPARTMENT. |
| | THE ENGINEERING DEVELOPMENT APPROVAL APPLICATION FORMS |
| | CAN BE DOWNLOADED AT: HTTP://WPB.ORG/DEPARTMENTS/ENGINE |
| | ERING-PUBLIC-WORKS/FORMS,-PERMITS-APPLICATIONS |
| | |
| | 2. PROVIDE A COPY OF THE SFWMD ERP FOR THIS PROPOSED |
| | DEVELOPMENT. |
| | |
| | 3. DEMOLITION AND CONSTRUCTION PLANS WILL REQUIRE |
| | DEVELOPMENT OF A STORMWATER POLLUTION PREVENTION PLAN. |
| | |
| | TRACY WARD, PE |
| | SENIOR STORMWATER ENGINEER |
| | ENGINEERING SERVICES DEPARTMENT |
| | 561-494-1120 |
| | [email protected] |
| | |
| |
Print |