2020-10-23 16:44:581. SATISFIED- / SHEET A0.102 LIST BUILDING FOOTPRINT
 REQUIREMENT AS MINIMUM PERCENTAGE, IT IS A MAXIMUM
 PERCENTAGE. PLEASE CORRECT DATA TO ACCURATELY REFLECT
 REQUIREMENT.
 2. PARTIALLY SATISFIED - PLEASE LIST THE REQUIRED GUEST
 PARKING FOR THE MICROUNITS.- / SHEET A0.102 STILL LIST
 328 RESIDENTIAL UNITS WITHIN THE PROJECT DESCRIPTION
 AND THE REQUIRED PARKING DATA. PLEASE ADJUST TO THE
 CURRENT PROPOSAL OF 230 UNITS. TABLE IN THE SAME SHEET
 LIST 202 REGULAR RESIDENTIAL UNITS AND 23 MICRO UNITS
 FOR A TOTAL OF 205 NOT THE NEW 230 LISTED. PLEASE
 CORRECT AND ADJUST ALL RELATED CALCULATIONS. SHEET
 A0.06 OF SITE PLAN PACKET ALSO HAS DISCREPANCIES.
 AVERAGE UNIT SIZE IS LISTED BUT NOT LEGIBLE.
 3. SATISFIED/ IN SHEET A1.500, THE HOTEL UNITS
 DESCRIPTION AND AREAS SUITE 1.3C AND 1.3W UNIT AREA IS
 NOT LISTED. PLEASE UPDATE TABLE AND INCLUDE INFORMATION
 TO CONFIRM COMPLIANCE WITH MINIMUM 350SF UNITS SIZE.
 4. SATISFIED/ PLEASE PROVIDE INFORMATION TO CONFIRM
 THAT REGULAR RESIDENTIAL UNITS COMPLY WITH THE AVERAGE
 800SF UNIT SIZE.
 5. SATISFIED/ PLEASE SUBMIT COLORED ELEVATIONS WITH
 CALL OUT MATERIALS.
 6. PARTIALLY SATISFIED- PLEASE CHECK THE FAR TABLE
 LISTED IN A0.06 AS THE FAR BY USE IN EVENT +RESTAURANT
 IS LESS THAN HOTEL RESTAURANT AND PUBLIC MEETING.-/
 PLEASE SUBMIT THE FAR DETAIL INFORMATION PER FLOOR AS
 SUBMITTED FOR SITE PLAN APPROVAL. SHEET A0.08 IN SITE
 PLAN APPROVAL HAS A TYPO IN THE LEVEL NUMBERS.
 7. NOT SATISFIED- MORE DETAIL IS NEEDED FOR THE GREEN
 SCREEN. PLEASE INDICATE PROPOSED PLANT MATERIAL FOR
 GREEN SCREEN AND INCLUDE A MAINTENANCE PLAN-/.PLEASE
 EXPLAIN HOW THE PLANTS PROPOSED FOR THE GARAGE
 SCREENING WILL GROW AND STILL MAINTAIN THE AIR FLOW
 REQUIRED FOR GARAGE VENTILATION.
 8. SATISFIED.-PLEASE CONFIRM THE GLASS UTILIZED FOR
 THIS PROJECT AT THE GROUND FLOOR IS NOT DARK TINTED OR
 REFLECTIVE TO THE POINT THAT THE INTERIOR IS NOT
 VISIBLE FROM OUTSIDE.
 9. SATISFIED.-FURTHER DISCUSSION IS NECESSARY FOR THE
 SELECTION OF THE LANDSCAPE MATERIAL TO BE LOCATED ON
 THE QUADRILLE BLVD MEDIAN.
 10. PARTIALLY SATISFIED-PLEASE INDICATE THE NEW
 LOCATION OF THE TROLLEY SHELTER -PLEASE CONFIRM PALM
 TRAM APPROVED THE RELOCATION OF THE EXISTING SHELTER TO
 THE PROPOSED LOCATION.
 11. SATISFIED- DUE TO THE PROPOSED MICROUNITS PROJECT
 IS REQUIRED TO PROVIDE 1 CAR SHARING STATION PER EVERY
 13 MICROUNITS. IF PARKING IS PROVIDED FOR THE
 MICROUNITS THERE MUST BE AT LEAST ONE CAR SHARING
 STATION ON SITE. PLEASE IDENTIFY LOCATION OF CAR
 SHARING STATION INSIDE PARKING GARAGE.
 12. SATISFIED- DUE TO THE PROPOSED MICROUNITS, PROJECT
 IS REQUIRED TO CONTRIBUTE A FEE INTO THE TROLLEY
 OPERATION FUND. FEE IS EQUAL TO $10 PER UNIT/MONTH. AN
 AGREEMENT WILL BE REQUIRED WITH THE PROPERTY OWNER
 BEFORE FINAL CO.
 13. SATISFIED- PLEASE IDENTIFY THE LOCATION FOR
 MICRO-MOBILITY STATION WITHIN THE PROJECT PUBLIC REALM
 AREA.
 14. SATISFIED - MINIMUM ACTIVE USE REQUIREMENT ALONG
 DIXIE HWAY IS 80% NOT 79%. PLEASE ADJUST TO CONFIRM
 COMPLIANCE. SITE PLAN INFORMATION SHOWS 80% NOT THE
 79%. IN ADDITION, USES BEHIND THE CURB CUT (OUTLINED IN
 RED) CANNOT BE COUNTED AS ACTIVE USES FOR THE PURPOSE
 OF CALCULATING MINIMUM ACTIVE USE REQUIRED AS THEY ARE
 BEHIND THE MINIMUM SETBACK AND NOT ADJACENT TO A PUBLIC
 OPEN SPACE. YOU MAY NEED TO EXTEND THE RETAIL A LITTLE
 BIT TO THE NORTH TO REDUCE THE GAP.
 15. SATISFIED- THE VARIANCE APPROVED BY THE DAC TO
 REDUCE ACTIVE USES ABOVE THE FIRST FLOOR ALONG
 QUADRILLE BLVD ALLOWED A REDUCTION FROM 60% TO 47%.
 PROPOSED PROJECT LISTS ACTIVE USES ONLY ALONG 31.9%.
 PLEASE INCREASE AMOUNT OF ACTIVE USES TO COMPLY WITH
 VARIANCE APPROVED. SITE PLAN INFORMATION SHOWS 47%
 ACTIVE USES BUT BUILDING PERMIT PACKET SHOWS 31.9%.
 PLEASE IDENTIFY WHERE THE DISCREPANCY EXISTS.
 16. SATISFIED- PLEASE PROVIDE A PEDESTRIAN CROSSING
 ACROSS DIXIE HWAY FROM THE SE CORNER OF THE PROJECT.
 17. SATISFIED- PLEASE RELOCATE AT LEAST 3 BIKE RACKS
 CLOSER TO THE OFFICE TOWER OPEN SPACE, AND RELOCATE AT
 LEAST 2 BIKE RACKS TO THE AREA CLOSER TO THE PROPOSED
 RETAIL.
 18. SATISFIED- GRADING PLAN SHEET 4 HAS LABELS BLACKED
 OUT.
 19. SATISFIED- A SEPARATE LANDSCAPE PERMIT WILL BE
 REQUIRED FOR THIS PERMIT.
 20. NOT SATISFIED-/PLEASE PROVIDE INFORMATION TO
 CONFIRM COMPLIANCE WITH PLANAR BREAK REQUIREMENT ALONG
 ALL FRONTAGES.
 FOR ADDITIONAL INFORMAITON PLEASE CONTACT ANA MARIA
 APONTE AT 561-822-1439.