| 2019-08-28 17:15:47 | THE FOLLOWING COMMENTS ARE FROM THE REVIEW OF THE |
| | AUGUST 22, 2019 ROUTED SUBMITTAL PACKAGE. |
| | |
| | 1. CONFIRM THERE WILL NOT BE A RAISED CURB BETWEEN THE |
| | PLANTERS ALONG N. DIXIE HWY AND THE ADJACENT SIDEWALK |
| | AND THAT RUNOFF FROM THE SIDEWALK WEST OF THE PLANTERS |
| | WILL BE ABLE TO FLOW INTO THE PLANTERS. |
| | |
| | 2. PROVIDE VIDEO OF EXISTING STORM PIPES ON 4TH STREET. |
| | SOME PIPES MAY BE VCP. (REPEAT COMMENT) |
| | |
| | 3. ADD THE CONVERSION EQUATION TO NGVD1929 TO GENERAL |
| | NOTE #7 ON THE COVER SHEET. (REPEAT COMMENT) |
| | |
| | 4. CALL OUT THE TYPE OF CURB RAMPS AND ADA MATS FOR |
| | DRIVEWAYS CROSSING THE SIDEWALK ON 4TH STREET.(REPEAT |
| | COMMENT) |
| | |
| | 5. CIVIL PLAN 5 SIGNING AND MARKING PLAN: |
| | A. PARKING DIMENSIONS DO NOT LINE UP WITH THE STRIPING |
| | ON 4TH STREET.(REPEAT COMMENT) |
| | |
| | 6. PROVIDE DIMENSIONS AND ELEVATIONS (TOP AND BOTTOM OF |
| | TRENCH) OF THE EXFILTRATION TRENCHES |
| | |
| | 7. DIFFERENT VERTICAL DATUMS REFERENCED ON THE CIVIL |
| | AND ARCHITECTURAL PLANS AND THE FFE'S VARY: |
| | CIVIL PLANS LIST FFE'S AS: |
| | A. 15.70 FEET NAVD88 FOR PROPOSED OFFICE TOWER |
| | B. 13.95 FEET NAVD88 FOR PROPOSED RESIDENTIAL TOWER |
| | C. 13.20 FEET NAVD88 FOR PROPOSED RETAIL BUILDING. |
| | |
| | THE ELEVATION VIEWS OF THE ARCHITECTURAL PLANS LIST |
| | FFE'S AS: |
| | A. 15 FEET 6 INCHES NGVD29 FOR THE PROPOSED OFFICE |
| | TOWER |
| | B. 13 FEET 9 INCHES NGVD29 FOR THE PROPOSED RESIDENTIAL |
| | TOWER |
| | C. 13 FEET 0 INCHES NGVD29 FOR THE PROPOSED RETAIL |
| | BUILDING. |
| | |
| | 8. EAST ELEVATION ON SHEET A2.01 SHOWS 18 FEET 0 INCHES |
| | FROM THE LEVEL 2 PODIUM TO THE GROUND LEVEL BUT |
| | DIFFERENCE IN ELEVATIONS IS 10.5 FEET (33 FEET 6 INCHES |
| | MINUS 13 FEET 0 INCHES). |
| | |
| | TRACY L. WARD, P.E. |
| | SENIOR STORMWATER ENGINEER |
| | ENGINEERING SERVICES DEPARTMENT |
| | [email protected] |
| | 561-494-1120 |
| | |
| |