| Plan Review Notes For Project Z17020026 |
| Project Number |
Z17020026 |
|
| Review Stop |
STORM |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2017-05-09 10:52:33 | FOLLOWING COMMENTS FROM APRIL 5, 2017 REVIEW PACKAGE: | | | | | | CONCEPTUAL LEVEL REVIEW. | | | 1. AT SOUTH END OF NARCISSUS AVE IS AN EXISTING STORM | | | MANHOLE WITHIN THE CROSSWALK. THE 15" RCP AT THE NW | | | INVERT SHOULD BE REMOVED AND THE HOLE PLUGGED. | | | | | | 2. WEIRS WILL BE NEEDED IN PROPOSED STORM MANHOLE A1 | | | AND INLET A3 TO RETAIN WATER IN THE EXFILTRATION | | | TRENCH. | | | | | | 3. DRAINAGE STRUCTURE FRAMES THAT WILL NEED TO BE | | | ADJUSTED MORE THAN 6" WILL REQUIRE CONCRETE RISERS TO | | | BE ADDED BELOW THE TOP SLAB. | | | | | | 4. THERE APPEARS TO BE A LOW SPOT AT THE SW CORNER OF | | | NARCISSUS AVE AND 2ND ST. PROPOSED SPOT GRADE OF 7.0 | | | SHOWN AT STOP BAR. CB TO WEST ON 2ND ST. WILL BE AT | | | ELEVATION 7.28. CB TO SOUTH ON NARCISSUS AVE WILL BE AT | | | 7.15. | | | | | | 5. ADD CATCH BASINS ON 2ND ST TO CAPTURE THE RUNOFF | | | BEFORE THE CURB RAMPS NEAR FLAGLER DRIVE. CONNECT TO | | | NEAREST DRAINAGE SYSTEM. | | | | | | TRACY L. WARD, P.E. | | | SENIOR STORMWATER ENGINEER | | | ENGINEERING SERVICES DEPARTMENT | | | [email protected] | | | 561-494-1120 |
| |