2017-02-07 08:59:57FROM: RAY CARANCI, LANDSCAPE PLANNER
 PROJECT: BANYAN CAY PD AMENDMENT Z17010007
 FEBRUARY 7, 2017
 I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND
 PROVIDE THE FOLLOWING COMMENTS:
  
 1. PLEASE PROVIDE A COMPARISON COUNT FOR TREE AND SHRUB
 QUANTITIES COMPARING THE PROPOSED PLAN TO THE APPROVED
 LANDSCAPE PLAN.
  
 2. SHEETS L-1 AND L-2 GUARDHOUSE DO NOT SHOW WATER,
 SEWER, DRAINAGE LINES OR LIGHTING LOCATIONS. PLEASE
 SHOW THESE SYSTEMS ON THE LANDSCAPE PLAN AND MAKE ANY
 ADJUSTMENTS NECESSARY TO AVOID CONFLICTS.
  
 3. PLEASE PROVIDE WATER NEEDS CATEGORY FOR EACH SPECIES
 ON ALL PLANT LISTS FROM THE SFWMD WATERWISE GUIDE AND
 SHOW COMPLIANCE WITH THE FLORIDA FRIENDLY LANDSCAPE
 CHART SECTION 94-442 (G).
  
 4. PLEASE SHOW LOCATIONS OF ROOT BARRIERS TO PROTECT
 INFRASTRUCTURE AND TREES FROM CONFLICTS. THIS INCLUDES
 WATER, SEWER, DRAINAGE, SIDEWALKS AND CURBS, AND ANY
 FIELD STRUCTURES THAT COULD BE IMPACTED BY TREE ROOTS.
  
 5. LANDSCAPING FOR LOT 1 WILL BE SEPARATE FROM THE
 COMMON AREA LANDSCAPING. PLEASE CLEARLY SHOW THE LOT
 LINES FOR THE SINGLE FAMILY LOTS AND ADJUST PLAN TO
 AVOID PLACING COMMON AREA LANDSCAPING WITHIN LOT LINES
 ON SHEET L-2 GUARDHOUSE.
  